• 제목/요약/키워드: Contol

검색결과 97건 처리시간 0.026초

생산, 측정 및 교정 프로세스에서 오차 유형화에 의한 확장 공정능력지수의 개발 (Development of Extended Process Capability Index in Terms of Error Classification in the Production, Measurement and Calibration Processes)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제11권2호
    • /
    • pp.117-126
    • /
    • 2009
  • We develop methods for propagating and analyzing EPCI(Extended Process Capability Index) by using the error type that classifies into accuracy and precision. EPCI developed in this study can be applied to the three combined processes that consist of production, measurement and calibration. Little calibration work discusses while a great deal has been studied about SPC(Statistical Process Contol) and MSA(Measurement System Analysis). EPCI can be decomposed into three indexes such as PPCI(Production Process Capability Index), PPPI(Production Process Performance Index), MPCI(Measurement PCD, and CPCI(Calibration PCI). These indexs based on the type of error classification can be used with various statistical techniques and principles such as SPC control charts, ANOVA(Analysis of Variance), MSA Gage R&R, Additivity-of-Variance, and RSSM(Root Sum of Square Method). As the method proposed is simple, any engineer in charge of SPC. MSA and calibration can use efficientily in industries. Numerical examples are presentsed. We recommed that the indexes can be used in conjunction with evaluation criteria.

곡선부 주행성능 향상을 가진 틸팅 열차의 DCU(Door Contol Unit)의 신뢰성 분석 (Reliability Analysis of Door Control Unit of Korean Tilting Tran)

  • 송용수;한성호;김남포
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.941-946
    • /
    • 2007
  • In this paper, as the step to assess and enhance the reliability of Korean Tilting Train eXpress (T.T.X), Door system is selected and reliability analysis is carried out. The door system is classified into subsystems and functional block diagrams and reliability block diagrams are drawn.Expessions for evaluating the reliability are derived and Mean Kilometer between Service Failure is calculated using the trial track test results. The calculation result show reliability growth of proposed system. This paper developed RAMS to make a door system of T.T.X. (Tilting Train eXpress) with maximum operation speed of 180 km/h.

  • PDF

인조보석 성장을 위한 DC-MOTOR 제어 구현 (Implementation of Position Control DC-Motor for $Al_2O_3$ Growth)

  • 조현섭;김성운
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2006년도 춘계학술발표논문집
    • /
    • pp.298-301
    • /
    • 2006
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal($Al_2O_3$) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($Al_2O_3$) growth and we will design about realtime monitoring systems of the automatic gas contol DC- Motor for single crystal($Al_2O_3$) growth

  • PDF

슬라이딩 관측기를 이용한 유도전동기의 센서리스 벡터제어 (Sensorless Vector Control of Induction Motor using Sliding Observer)

  • 박지호;김구형;조용길;김춘삼;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1922-1924
    • /
    • 1998
  • In this paper, the robust vector control method of Induction Motor for the purpose of improving the system performance deterioration caused by parameter variations is proposed. The full order state observer estimates the stator current and the rotor flux by using the state prediction of state variables. And, the motor speed is estimated without speed sensor using the full order state observer. Also, the parameter variation is compensate by the Sliding Observer. By using this method, speed sensorless control and current contol with no affection of the parameter variation can be obtained simultaneously.

  • PDF

유황곡선 보전을 위한 저류형 강우유출수 제어설비 설계 (Design of Storage-based Stormwater Contol Facilities for Preserving Flow Druation Curve)

  • 최치현;김호성;김상단
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.1124-1128
    • /
    • 2010
  • 본 연구는 도시 개발이전의 유황곡선과 개발이후의 유황곡선을 일치시키기 위하여 강우유출수 제어설비의 크기 결정과 관련된 복합 설계기법을 제안하는데 있다. 우선 CN값을 산출 및 보정한 후, IETD에 따라 분할된 강우사상에 NRCS-CN 방법을 적용하여 직접유출량과 침투량을 산정한다. 직접유출량과 침투량의 장기적인 통계치는 개발이전, 개발이후, 개발이후 유수지 설계, 그리고 개발이후 제안된 복합설계의 경우에 대하여 각각 분석된다. 개발이전의 직접유출량과 침투량을 재현하기 위해서 유전자 알고리즘을 적용하여 유수지 및 저류지의 크기를 추정한다. 분석결과 복합설계 강우유출수 제어설비를 적용하였을 때 개발이전의 지표면 유출수와 침투수의 평균을 잘 재현하였고, 개발이전의 유황곡선이 개선될 여지가 충분히 있음을 확인하였다.

  • PDF

인버어터구동 이상서어보 전동기의 마이크로프로세서에 위한 입상제어 (The Phase Contol Method of 2-Phase Servomotor Driven with Microprocessor-based Inverter)

  • 원종수;장도현
    • 대한전기학회논문지
    • /
    • 제36권2호
    • /
    • pp.80-87
    • /
    • 1987
  • This paper describes a new approach to control the two-phase servomotor driven with microprocessor based inverter. Conventional 6-step driving system has some shortcomings such as vibration and loss caused by the harmonic voltage. An attempt has been made to eliminate the harmonic content of output waveform by PWM technique and to simplify the control system by phase control method. In realizing the phase control by PWM technique proposed by this paper, control circuit and algorithm has been suggested. The proposed method has been applied to the speed control system with PI controller to confirm the adaptation of the servo system and experimental results has been compared with the computer simulation.

제어봉 구동장치용 횡자속형 전동기의 제어기 개발 (Development of the Controller for TFM with Contol-Rod)

  • 김종무;정연호;강도현;임태윤;김동희;이석규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.284-287
    • /
    • 2001
  • In the System-integrated modular advanced reactor(SMART), the motor for Control element drive mechanism(CEDM) requires high density power and simple drive mechanism to reduce volume because of restriction by install-space and must satisfy the reactor operating circumstances with high pressure and temperature. To Maximize the characteristics of the TFM, we chose the asymmetric bridge converter as the driving system for TFM. Because two switching devices are connected in series with the stator winding of each phases in the asymmetric bridge converter all the phases are not affected by another phase but controlled independently. Also, this converter has many advantages that the various control methods can be adopted, it is easy to control, and that in case that the switching devices of a phase are damaged, the affects can be minimized.

  • PDF

고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이주홍;이일무;김주락
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

매입형 영구자석 동기전동기의 고성능 약계자 제어 (The High Performance Flux Weakening Control of Interior Permanent Magnet Synchronous Motor)

  • 이중호;김장목;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1051-1053
    • /
    • 1993
  • In this paper, the new flux weakening contol algorithm for the drive system of Interior Permanent Magnet Synchronous Motor(IPMSM) is proposed which includes the feedback of torque and current The torque error is used in order to control the current phase angle in the field weakening control. The proposed control method is compared with the stator flux oriented vector control method. Through the simulation the prominence of the proposed control method is verified.

  • PDF

8255A를 이용한 전동밸브의 모니터링 시스템 구현 (Implementation of Monitering system of Electromotion valve using 8255A)

  • 조현섭;유인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1694-1695
    • /
    • 2007
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal(Al2O3) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($Al_{2}O_{3}$) growth and we will design about realtime monitoring systems of the automatic gas contol DC- Motor for single crystal($Al_{2}O_{3}$) growth

  • PDF