• 제목/요약/키워드: Continuous suction

검색결과 49건 처리시간 0.034초

결장뉴 전기활동도에 대한 Ouabain과 Vanadate의 작용 (Effects of Ouabain and Vanadate on the Spontaneous Contractions and Electrical Activity in Guinea-pig Taenia Coli)

  • 박종규;김기환;서인석
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.189-206
    • /
    • 1988
  • The effects of ouabain on the contractile and electrical activities were investigated in the isolated preparations of guinea-pig taenia coli, and compared with those of vanadate. Spontaneous contractions were recorded with force transducer, and electrical activites were measured by use of suction electrode, or single sucrose-gap technique. The contractions were induced by the electrical stimulation for 5 seconds every 1 minute with alternating current (60 Hz, 3.0 V/cm) through the platinum electrodes located in parallel with the long axis of the preparation. All experiments were performed in tris-buffered Tyrode solution which was aerated with $100%{\;}O_2$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) Responses of spontaneous contractions to ouabain were concentration-dependent; $10^{-7}M$ ouabain caused a rise of basal tone. Above the concentration of $10^{-6}M$ ouabain, an initial increase followed by a decrease in tension was observed. 2) A continuous spike discharge was induced by the administration of $10^{-7}M$ ouabain. Above $10^{-6}M$ ouabain, a transient initial increase followed by a decrease in spike frequency and amplitude was produced, and finally membrane potential was sustained at a certain level without a spike discharge. 3) The characteristic response to $10^{-7}M$ ouabain was not blocked by the pretreatment with $10^{-7}M$ atropine. 4) The electrically induced contractions were completely suppressed at the concentration of $2{\times}10^{-7}M$ ouabain. These contractions were blocked more rapidly in paralled with the increase in ouabain concentration. 5) Effects of vanadate on the spontaneous activities were quite different from those of ouabain; $10^{-6}M$ vanadate increased the amplitude of contractions and $10^{-5}M$ vanadate increased slightly both amplitude and frequency of spontaneous contractions. $10^{-4}M$ vanadate showed irregular phasic contractions superimposed on the increased basal tone. 6) $10^{-5}M$ vanadate depolarized the membrane potential and shortened the interval between the bursts of spike discharge, whereas $10^{-4}M$ vanadate induced continuous spike discharge with membrane depolarization. 7) Vanadate caused a characteristic inhibitory response to the contractions induced by electrical stimulation; An initial rapid inhibition of tension development and then gradual recovery to a certain level. From the above results, the following conclusions could be made: 1) The rise of basal tone at $10^{-7}M$ ouabain is due to continuous spike discharge without a silent period. The continuous spike discharge is likely to be associated with a slight membrane depolarization caused by the blockage of Na pump. 2) The biphasic response induced by above $10^{-6}M$ ouabain seems to occur by the different mechanisms. The initial increase in tension is associated with depolarization along with an increase in spike frquency, whereas the subsequent relaxation occurs through a non-electrical mechanism. 3) The characteristic response to $10^{-7}M$ ouabain is resulted not from the action on intrinsic nerve terminal, but from its direct action on the membrane of smooth muscle cells. 4) The phasic contractions superimposed on the increased basal tone at the concentration of $10^{-4}M$ vanadate is resulted from the continuous spike discharge with membrane depolarization, of which mechanism remains unknown. 5) The inhibitory action of ouabain on the electrically induced contractions suggests that the increasein intracellular Na in some way inhibits the electrically induced $Ca^{2+}$ influx. The mechanism of vanadate action on the induced contractions remains unknown.

  • PDF

불포화토 칼럼시험을 통한 연속강우와 반복강우의 강우침투속도 분석 (Analysis of Rainfall Infiltration Velocity in Unsaturated Soils Under Both Continuous and Repeated Rainfall Conditions by an Unsaturated Soil Column Test)

  • 박규보;채병곤;박혁진
    • 지질공학
    • /
    • 제21권2호
    • /
    • pp.133-145
    • /
    • 2011
  • 본 연구는 불포화 풍화토별 강우지속시간 및 비강우시간에 따른 강우침투속도 관계를 파악하기 위하여 국내에서 산사태 발생빈도가 높은 선캠브리아기 편마암 풍화토와 백악기 화강암 풍화토를 대상으로 불포화 풍화토 칼럼시험을 하였다. 본 연구에서는 일정시간 간격으로 체적함수비를 측정하기 위하여 함수비 측정 TDR센서를 이용하였다. 강우강도 조건은 20 mm/h로 선정하여 연속강우와 반복강우를 재현하였으며, 반복강우의 경우 강우시간과 비강우시간을 조절하였다. 그리고 흙의 단위중량 조건은 편마암 풍화토의 경우 현장 건조단위중량보다 낮고 칼럼상부유출이 일어나지 않는 1.35 $g/cm^3$, 화강암 풍화토의 경우 현장 건조단위중량인 1.21 $g/cm^3$로 선정하였다. 편마암 풍화토와 화강암 풍화토 총 강우량 200 mm인 조건에서 $2.090{\times}10^{-3}{\sim}2.854{\times}10^{-3}$ cm/s와 $1.692{\times}10^{-3}{\sim}2.012{\times}10^{-3}$ cm/s로 총 강우량 100 mm에서의 $1.309{\times}10^{-3}{\sim}1.871{\times}10^{-3}$ cm/s와 $1.175{\times}10^{-3}{\sim}1.581{\times}10^{-3}$ cm/s보다 강우침투속도가 빠르게 나타났다. 이는 동일 시간당 토층 내 주입되는 물의 양이 200 mm조건에서 100 mm조건보다 많기 때문이다. 완전 건조 상태의 강우침투속도와 강우가 반복되어 물을 함유하고 있는 상태의 강우 재침투속도를 비교해 보면, 편마암 풍화토와 화강암 풍화토의 최초 강우침투속도인 $1.309{\times}10^{-3}{\sim}2.854{\times}10^{-3}$ cm/s와 $1.175{\times}10^{-3}{\sim}2.012{\times}10^{-3}$ cm/s보다 강우 재침투속도가 $1.307{\times}10^{-2}{\sim}1.718{\times}10^{-2}$ cm/s와 $1.789{\times}10^{-2}{\sim}2.070{\times}10^{-2}$ cm/s로 높게 나타났다. 이는 토층 내 공기의 함입량이 줄어들어서 불포화 투수계수에 영향을 미치는 흡입력(matric suction)이 감소한 것이 원인으로 생각된다.

강우시 광산폐기물 적치사면의 침투 및 안정성에 대한 수치해석 (Numerical Analysis of the Seepage from and Stability of a Mine Waste-dump Slope during Rainfall)

  • 송영석
    • 지질공학
    • /
    • 제25권1호
    • /
    • pp.57-66
    • /
    • 2015
  • 부산 임기광산의 광산폐기물 적치사면을 대상으로 강우에 따른 사면의 침투해석과 안정해석을 연계하여 수행하였다. 광산폐기물 적치사면의 경사는 40-45°로써 비교적 급한 편이고, 암반층 상부의 광산폐기물은 약 7-8 m의 두께로 존재하며, 지하수위는 지표면으로부터 약 6.6 m 깊이에 위치하고 있다. 현장에서 채취한 시료를 대상으로 각종 실내시험을 수행하여 강우 시 침투거동 및 사면안정해석을 위한 입력자료를 선정하였다. SEEP/W를 이용하여 다양한 강우강도 조건에서 침투해석을 수행한 결과 강우지속시간이 길어짐에 따라 습윤전선은 하강함을 알 수 있다. 강우강도가 50 mm/hr 이상 이고 강우지속시간이 24시간 이상인 경우 침윤전선은 사면의 하단부에서 지하수위와 만나게 되므로 토층 전체가 포화됨을 알 수 있다. 침투해석결과를 연동하여 SLOPE/W를 이용하여 사면안정해석을 수행한 결과 강우침투로 인한 침윤전선이 하강함에 따라 사면안전율은 낮아짐을 알 수 있다. 강우가 5-6시간 지속적으로 발생된 이후 사면안전율은 급격하게 낮아지며, 이후 사면안전율이 미소하게 회복되다가 수렴한다. 사면안전율이 급격하게 낮아지는 이유는 강우로 인한 임계 활동면과 침윤전선의 깊이가 유사하여 해당깊이까지 간극수압이 증가되고 모관흡수력이 감소되었기 때문이다.

하수처리를 위한 막결합형 $A_2O$공정에서 최적 내부 순환율 및 MLSS 농도에 관한 연구 (A Study on the Optical Internal Recycle Rate and MLSS Concentration of Membrane Coupled $A_2O$ Process for Wastewater Treatment)

  • 김관엽;김진모;김형수;이상백;박유진;배성수
    • 멤브레인
    • /
    • 제15권2호
    • /
    • pp.114-120
    • /
    • 2005
  • 본 연구의 목적은 도시 하수처리를 위한 막결합형 $A_2O$공정에 관해 실제적인 정보를 얻고자 하는 것이다. 공경 $0.25\;{\mu}m$의 평판형 정밀여과막을 공기가 주입되는 호기조에 침지시켜 처리수는 저압으로 여과된다. 인공폐수를 대상으로 최적의 처리수질과 장기운전의 안정성 확보를 위한 내부반송율과 MLSS 농도 등의 최적 운전인자를 산정하고자 하였다. 내부반송은 각각 호기조에서 무산조로 반송한 것을 type 1, 무산조에서 혐기조로 반송한 것을 type 2라고 규정지었다. 플럭스는 15 LMH, type 1을 2Q로 고정하고 실험하였을 때 최적의 운전 조건은 MLSS 농도는 11,000 mg/L, type 2가 IQ로 나타났다. 이때, BOD $COD_{cr}$, T-N, T-P의 제거율이 각각 $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$로 타 내부반송율보다 효과적이었다.

자연기흉에 대한 Thoracoscopy 의 임상적의의 (Clinical Significance of Thoracoscopy on Spontaneous Pneumothorax)

  • 김영태;김근호
    • Journal of Chest Surgery
    • /
    • 제8권1호
    • /
    • pp.19-28
    • /
    • 1975
  • The thoracoscopic study was reported on 21 cases of spontaneous pneumothorax requiring surgical management, and clinical values of thoracoscopic examination on spontaneous pneumothorax were also discussed. patients were treated in the Department of .Thoracic Surgery, Hanyang University Hospital for the period of two Years from May 1972 to April 1974. For exact detection of etiologic factors on spontaneous pneumothorax, the thoracoscopic examination in the intrapleural space was performed in parallel with X-ray study. this study, the difference of diagnostic and therapeutic significance between radiological and thoracoscopic findings were observed and compared simultaneously. The results are summerized as follows: Patients age was distributed between 3 and 70 years old with highest incidence in the age group of sixty decade [33. 3%], and sex ratio of male to female was 5:2. The tuberculous processes which developed superficial subpleural layer in the lung parenchyme, on the pulmonary surface could be observed by thoracoscopic examination in a characteristic picture. detection ratio of pulmonary tuberculosis by the radiologic study to that by thoracoscopy was 8:2. The adhesion between the visceral and the parietal pleura which could possibly make a rupture of the alveola and the visceral pleura was found to be localized in a small area of the lung surface. The other part of the lung surface was free of the adhesion and, therefore, the movement of the lung took place completely without any difficulty. The ruptured orifice of the pleura and pathological changes surrounding the orifice can be detected by thoracoscopy, but not by other means such as radiologic examination. A single tuberculous bleb and multiple emphysematous blebs were found on 6 cases out of 21 cases of spontaneous pneumothorax. Among these cases, radiologic Study revealed the bleb only in one patient. On the other hand, the blebs were found in all the six patients by means of thoracoscopic examination. It gives the detection ratio of bleb by radiologic study to that by thoracoscopy was 1:6. By thoracoscopy, the rupture on the lung surface were visualized on the 10 patients out of a total of 21 patients [10 patients of visual rupture]. However, the rupture of the pleura was not observed on the rest of 11 patients even by thoracoscopic examination [11 patients of non visual rupture]. Five patients [50%] out of ten who had the visual rupture on the lung surface was required a surgical operation to remove pneumothorax. For the patients who were detected to have the visual rupture of the pleura by thoracoscopy, be considered in the early stage of closed thoracostomy. of 21 patients, 16 patients [11 patients of non visual rupture of the pleura and 5 patients of visual rupture of the pleura] who received no surgical management, were treated with closed thoracostomy with continuous suction, and the` pneumothorax was healed completely up in each cases. Therapeutic measures for the remaining 5 patients of visual rupture of the pleura who were subjected to surgical approach for radical treatment of spontaneous pneumothorax were accordingly complicated, and the following different procedures were properly indicated case by case, that is, rib resection thoracostomy, simple closure of ruptured visceral pleura, wedged resection of the lung, and lobectomy.

  • PDF

굴곡형 기관지내시경을 이용한 Gelfoam 폐쇄로 치료한 말단부 기관지흉막루 1예 (A Case of Peripheral Bronchopleural Fistula Treated by Flexible Bronchoscopy with Gelfoam Occlusion)

  • 이승헌;허규영;김제형;이상엽;신철;심재정;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제53권2호
    • /
    • pp.221-226
    • /
    • 2002
  • 다양한 원인으로 인해서 발생하는 기관지흉막루는 일차적인 치료에 반응이 없을 경우에는 수술적 치료를 고려해야 하나, 대부분 환자들의 양호하지 못한 전신 상태로 인하여 수술을 시행할 수 없는 경우가 많다. 이런 경우 굴곡형 기관지내시경을 이용한 치료가 시행될 수 있는 데, 저자 등은 농흉이 동반된 괴사성 폐렴 및 폐농양 환자에서, 흉관 삽관 후에 발생한 말단부 기관지흉막루를 기관지내시경을 이용한 Gelfoam 폐쇄로 치료한 1례가 있어 보고하는 바이다.

파워 조절 방법에 따른 풍력 터빈의 방사 소음 특성 (Characteristics of Noise Emission from Wind Turbine According to Methods of Power Regulation)

  • 정철웅;정완섭;신수현;전세종;최용문;정성수
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.864-871
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and full span pitch control. The main purpose of this paper is to experimentally identify the characteristics of noise emission of wind turbines according to the power regulation types. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines (WT) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence, third-octave band levels and tonality are evaluated for both of WTs. It is observed that equivalent continuous sound pressure levels (ECSPL) of the stall control type of WT continue to increase with increasing wind speed whereas those of the pitch control type of WT show less correlation with wind speed. These observed characteristics are believed to be due to the different airflow patterns around the blade between the stall regulation and the pitch control types of WT; the airflow on the suction side of blade in the stall types of WT are separated at the high wind speed. It is also found that the 1.5 MW WT using the stall control emits lower sound power than 660 kW one using the pitch control at wind speeds below 8m/s, whereas sound power of the former becomes higher than that of the latter in the wind speed over 8m/s. This wind-speed dependence of sound power leads to the very different noise omission characteristics of WTs depending on the seasons because the average wind speed in summer is lower than 8m/s whereas that in summer is higher. Based on these experimental observations, it is proposed that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

모형실험을 이용한 균질한 사질토 사면의 붕괴형상 분석 (Analysis of the Failure Mode in a Homogeneous Sandy Slope Using Model Test)

  • 송영석;박준영;김경수
    • 지질공학
    • /
    • 제32권2호
    • /
    • pp.209-219
    • /
    • 2022
  • 본 연구에서는 강우에 따른 사면 내 지반특성 변화와 사면붕괴 형상을 실험적으로 규명하기 위하여 인공강우장치와 모형토조를 이용한 실내모형실험을 수행하였다. 이를 위하여 균질한 모래를 대상으로 모형 실험을 수행하였으며, 계측장치를 이용하여 강우침투에 의한 사면 내 포화양상을 조사하였다. 모형사면은 30°의 경사면에 35°의 사면경사로 조성하였고 강우강도는 50 mm/hr를 적용하였다. 토층의 깊이는 모형토조의 크기를 고려하여 35 cm로 선정하고 TDR센서는 깊이별로 설치하여 시간에 따른 지반특성 변화를 고찰하였다. 실험결과 강우 시 모형사면은 강우침투로 인하여 지표에서 지중으로, 선단부에서 정상부로 포화가 진행됨을 알 수 있다. 즉, 강우의 침투로 인하여 사면의 선단부가 먼저 포화되고 이후 지속적인 강우로 인하여 포화의 영역이 사면의 선단부로부터 정상부로 확대됨을 알 수 있다. 모형사면의 붕괴는 사면의 선단부에서부터 붕괴가 시작되어 이후 사면의 정상부로 확장되는 진행성 사면붕괴가 발생되었으며, 최종 사면붕괴시점에서 붕괴면적이 급격하게 증가하였다. 또한 활동면은 원호활동의 형태로 발생되었다. 한편, 사면 내 모관흡수력이 흙-함수특성곡선(SWCC)에서 산정된 공기함입치(AEV)에 이르게 되면 사면붕괴가 발생되는 것으로 나타났다.

저체중아에 있어 기관내 흡인전 흉부진동법의 기관과 산소포화 변화간의 관계 연구 (The Study on the Relationship Between the Duration of Chest Vibration prior to Endotracheal Suctioning and the Changes in Oxygen Saturation in Low-Birth-Weight Infants)

  • Ahn, Young-Mee
    • 대한간호학회지
    • /
    • 제25권3호
    • /
    • pp.597-607
    • /
    • 1995
  • 1960년대 이후 인공호흡기(mechanical ventilator)의 보급과 최근 의료과학의 발달, 간호의 질적 향상의 결과로 저체중출생아를 포함한 고위험 신생아의 생존율이 높아져왔다. 호흡장애증후군(RDS)은 일차적으로 폐포의 완전한 확장을 위해 필요한 계면활성물질(surfactant)의 부족, 미발달된 심폐기능에 의한 병리적 현상으로 저체중아의 가장 큰 원인이 되어왔다. RDS로 인해 인공호흡기에 의존해 있는 저체중아의 경우 적절한 산소공급과 이를 위한 호흡의 유지는 치료의 가장 큰 핵심이 되며, 이를 위한 기관내 흑은 비인두 흡인 (nasopharyngeal suction)은 신생아 중환자실(NICU)의 가장 중요한 간호행위가 되어왔다. 인공호흡기를 위한 기관삽관은 그 자체가 기도의 성모운동을 방해하고 기침반사를 억제시켜 폐 분비물의 효과적 배출을 억제하며, 특히 저체중아의 경우 조산과 관련하여 미발달된 흥곽운등과 심폐기능은 폐분비물의 이동을 저해하는 요소이다. 따라서 기도내의 분비물의 이동을 효과적으로 하여 흡인 시에 최대한의 효과를 돕기 위해 흥곽 물리요법(chest physiotheraphy : CPT)의 한 형태인 흉곽진동법 (Chest Vibration : CV)가 행해져 왔다. 그러나 저체중아를 위한CV의 임상적 적용은 그 대상의 생리적 특성, CV의 적용부위(site)와 기간(duration)에 대한 과학적 근거 없이 만성감염이나 폐질환을 가진 성인이나 cystic fibrosis환자를 위한 CV protocol을 무분별하게 채택하여 저체중아에게 행하여져 왔다 이에 본 연구자는 저체중아에 대한 CV의 안전성을 평가하고, 이에 기초하여 저체중아에게 바람직한CV의 형태를 알아보고자 본 연구를 시작하였다. 연구설계는 CV의 안전성을 평가하기 위한 실험연구이다. CV의 안전성은 RDS치료의 가장 일차적 목표인 oxygenation변화에 의해 평가될 수 있으므로, 본 실험 연구에서는 Pulse oximeter에 의해 계속적으로 측정된 산소포화 변화(oxygen saturation change)를 측정하였다. 실험대상은 미국동부에 위치한 대학병원의 NICU에 입원하여 RDS와 관련된 호흡장애로 인공호흡기에 의존해 있는 10명의 저체중아였다. 인공호흡기에 의존된 모든 저체중아는 Pulse oximeter와 심폐기능 측정기(cardiopulmonary monitor)에 의해 산소공급과 호흡상태가 계속 측정되고 있었다. 실험대상의 평균 출생시 몸무게는 평균 1,3050gm(SD=580.6)이었고, 임신월령 은 평균 28.6주(SD=3.1)였다. RDS가 그들의 일차적 진단명이었고, 그중 4명은 pneumonia, atelectasis의 합병증을 가지고 있었다. 10명중 6명은 intermittent mandatory ventilation(IMV)의 형태로, 4명은 continuous positive airway pressure(CPAP)의 형태로 인공호흡기에 의존되어 있었고 CV시의 FiO2는 평균 42.3(SD=21.2)였다. CV는 중환아용 소형진동기 (minivibrator)를 이용해 가각 10명 의 간호사에 의해 행하여 졌고, 최소 22초에서 최대 100초 동안 실시되었다. 50%의 간호사는 30초에서 40초간 CV를 실시하였으며, CV의 적용부위도, 전후 흉곽부위, 혹은 병변이 있는 좌 우측, 흑은 양쪽 흉벽 등으로 다양했고, 적용방법도 원형으로 돌려가며(circular motion), 혹은 아래에서 위로, 혹은 아무런 기준없이 간호사의 기호에 따라 다양하게 적용되었다. 산소포화의 변화는 CV가 행해지기 전.후로 5초동안 관찰되었다. 연구의 결과, 산소포화 변화는 비 모수통계(non parametric statistics)의 일종인 Matched Paired Wilcoxon test로 분석 한 결과 CV후에 3%의 감소를 보였다(P<.05). 저체중아에 있어 산소포화의 3%감소는 임상적으로 중요한 의미가 없다고 사료되어지며, 실제 흡인전의 과도호흡에 의해 CV를 행하기 이전의 산소공급수준으로 돌아 왔다. CV실시 기간과 산소포화와의 상관관계는 비 모수통계인 Spearman rho correlation coefficient를 이용하여 분석하였는데, 이 두 변수는 서로 관계가 없는 것으로 나타났다(P>.05) 또한 CV와 흡인 후에 각각의 간호사들에게 CV를 필요로 한 저체중아의 기준, 적용부위, 기간, 방법등에 대한 기준을 물었으나 대상의 특성에 따른 간호사정에 의존하기보다는 간호사 각자의 선호하는 방법이나 습관에 라 행하는 것으로 나타났다. 결론적으로 CV와 산소포화 변화와의 관계, NICU에서 관찰된 CV의 임상적 적용을 기초로 저체중아에게 안전한 CV protocol은 신생아용 소형 진동기를 이용하여, 양쪽 흉곽의 늑골하측 변연 부위(low lateral costal margin)에서 시작하여 흉골 중앙부위 방향으로 30초 동안 진동기를 적용하는 것이 좋은 것으로 나타났다. 이에 CV의 효과를 평가하기 위한 보다 과학적인 접근방법으로, CV와 흡인의 결과인 가래(sputum)에 대한 연구를 제언하는 바이다.

  • PDF