• Title/Summary/Keyword: Continuous fiber

Search Result 428, Processing Time 0.04 seconds

Analysis of Mechanical Properties of Wood Flours Composites to Improve the Strength of Truck Deck Floor Boards (트럭 Deck Floor Board의 강도향상을 위한 목분복합재의 기계적특성 분석)

  • Yun, Sung-Woo;Go, Sun-Ho;Kim, Hong-Gun;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.24-30
    • /
    • 2019
  • The deck floor of a the cargo truck becomesis damaged and aged due to the continuous loading of the loading cargo and external environmental factors. Floor boards made of wood and metal are often used. In the case of wood, the cost is high due to the use of imported wood, and the strength is easily deterioratesd due to environmental factors. In the case of metal materials, the durability is higher than that of wood, but problems are raised due to the effect of major factors that hinder the weight reduction, and the effects of corrosion. In order to replace this stucturestructural design, this study proposed a wood fiber composite using natural raw materials. Woody composites are being used as environmentally and friendly exterior materials with the combined advantages of plastic, and wood,; low cost and low density. However, due to the nature of the woody composites, the properties are differentdiffer depending on the contents of the matrix, reinforcing agent, additives, compatibilizer, etc. In this study, we investigate these problems through analysis of the microstructure and mechanical properties according to proper content and injection molding conditions. As a result, it is considered that the wood deck composite can replaced the current Deck Floor Boardreplace current deck floor boards through continuous continued research and results of this study.

EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE (저출력 레이저조사가 동통반응에 미치는 영향)

  • Kim, Sung-Kyo;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.

  • PDF

A Study of the Development of Liquid-liquid Static Contactor Using Capillary Phenomena Induced by Highly Packed Fiber Bundle and its Characteristics (고밀집 섬유 집합체에 의해 유도된 모세관 현상을 이용한 정적 액-액 접촉장치의 개발과 그 특성 연구)

  • Kim, Kwang-Wook;Byeon, Kee-Hoh;Lee, Eil-Hee;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.4
    • /
    • pp.743-749
    • /
    • 1996
  • A new static contractor using capillary phenomena induced by a highly packed fiber bundle was developed for the solvent extraction. When two immiscible phases being cocurrently and forcedly fed into the packed fiber bundle, the contactor brings about a very large liquid-liquid contact area for mass transfer within a small definite space without any turbulence and drop phenomena. In order to test the characteristics and stability of the static contractor system, continuous extraction experiments of TBP-uranyl ion-nitric acid system were done and compared with the batch extraction experiment of the same chemical system. The performance of the static contractor were the same as that of the ideal batch extractor with the same extraction condition. For the increase of the extraction yield by the contactor, the increase of organic flow rate was required at a fixed aqueous flow rate, and a certain residence time of the aqueous phase flow within the contactor system had to be maintained to meet the performance of the batch system of the same phase ratio. The residence time in the case of TBP-uranyl ion-nitric acid system was about 1.9 minutes. This system was confirmed to be effective and stable enough for purposes of the kinetic study of solvent extraction as well as the mutual separation and purification of ordinary materials because of good reproducibility and the stable and large static liquid-liquid contact area.

  • PDF

Electrosorption of U(VI) by Surface-Modified Activated Carbon Fiber (표면처리 활성탄소섬유에 의한 U(VI)의 전기흡착)

  • Lee, Yu Ri;Jung, Chong Hun;Ryu, Seung Kon;Oh, Won Zin
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.60-65
    • /
    • 2005
  • The electrosorption of U(VI) from waste water was carried out by using activated carbon fiber(ACF) felt electrode in a continuous electrosorption cell. In order to enhance the electrosorption capacity at lower potential, ACF felt was chemically modified in acidic, basic and neutral solution. Pore structure and functional groups of chemically modified ACF were examined, and the effect of treatment conditions was studied for the adsorption of U(VI). Specific surface area of all ACFs decreases by this treatment. The amount of acidic functional groups decreases with basic and neutral salt treatment, while the amount increases a lot with acidic treatment. The electrosorption capacity of U(VI) decreases on using the acid treated electrode due to the shielding effect of acidic functional groups. Base treated electrode enhances the capacity due to the reduction of acidic functional groups. The electrosorption amount of U(VI) on the base treated electrode at -0.3 V corresponds to that of ACF electrode at -0.9 V. Such a good adsorption capacity was not only due to the reduction of shielding effect but also the increase of $OH^-$ in the electric double layer on ACF surface by the application of negative potential.

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

Weldability with Process Parameters During Fiber Laser Welding of a Titanium Plate (I) - Effect of Type and Flow Rate of Shielding Gases on Weldability - (티타늄 판재의 파이버 레이저 용접시 공정변수에 따른 용접특성 (I) - 실드가스 종류 및 유량에 따른 영향 -)

  • Kim, Jong Do;Kim, Ji Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1047-1053
    • /
    • 2016
  • In this study, welding of pure titanium was carried out by using a continuous wave fiber laser with a maximum output of 6.3 kW. Because brittle regions form easily in titanium as a result of oxidation or nitriding, the weld must be protected from the atmosphere by using an appropriate shielding gas. Experiments were performed by changing the type and the flow rate of shielding gases to obtain the optimal shielding condition, and the weldability was then evaluated. The degree of oxidation and nitriding was distinguished by observing the color of beads, and weld microstructure was observed by using an optical microscope and a scanning electron microscope. The mechanical properties of the weld were examined by measuring hardness. When the weld was oxidized or nitrified, the bead color was gray or yellow, and the oxygen or nitrogen content in the bead surface and overall weld tended to be high, as a result of which the hardness of the weld was thrice that of the base metal. A sound silvery white bead was obtained by using Ar as the shielding gas.

Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System (낙동강 수계의 섬유 및 화학 산업폐수로부터 발생하는 미량유해화학물질의 모니터링)

  • Kim Man-Il;Kang Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.145-152
    • /
    • 2006
  • Industry development caused numerical and quantitative increase of noxious chemical substances that contain risk assessment in water resources. For use of efficient water resources a pre-treatment of contaminant source which is flowed in water resources is recognized in essential process. Therefore, the discharged water quality from discharged company began to control contaminant by total amount of pollutant in domestic. However, to estimate closely chemical substances it is not proved up to now, monitoring is very important. This study achieved a monitoring of micro noxious chemical substance by fiber and chemistry industrial wastewater inflow to examine risk assessment of the water system of Nakdong river. Chloroform was measured highest among volatile organic compounds (VOCs) that the results of water quality of influent and effluent are detected from 7 companies of study area. The other side, because measured value of detected chloroform is indefinite detection level in the same company, it is difficulty in management of water quality. However it may not be much effects of the water system of Nakdong river because these company's effluent is high treatment efficiency of chloroform (more than 88%) in sewage treatment plant. On the other hand, in the investigated results for the European Union specified priority substance that is detected to relationship influent and effluent from fiber/chemistry associated industries, these substances were not detected and domestic data was hardly referred. Therefore, data construction of continuous monitoring about this water quality may have to be achieved certainly to utilize as country policy.

A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System (응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Kim, Seung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

Modified Nonlinear Static Pushover Procedures of MDOF Bridgesfor Seismic Performance Evaluation (내진성능평가를 위한 다자유도 교량의 수정 비선형 등가정적해석법)

  • Cho, Chang-Geun;Kim, Young-Sang;Bae, Soo-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.175-184
    • /
    • 2006
  • Two methods of the nonlinear static pushover analysis have been presented for the performance-based seismic design and evaluation of MDOF continuous bridges. Guidelines for buildings presented in FEMA-273 applying the Displacement Coefficient Method (DCM) and in ATC applying the Capacity Spectrum Method(CSM) have been modified for MDOF bridges. Two methods are compared with the time- history analysis. The lateral load distribution pattern for seismic loads has been examined in the static pushover analysis. The force-based fiber frame finite element has been implemented in the modeling of reinforced concrete piers.

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.