• Title/Summary/Keyword: Continuous Turbulence

Search Result 73, Processing Time 0.021 seconds

3D Modeling based on Digital Topographic Map for Risk Analysis of Crowd Concentration and Selection of High-risk Walking Routes (군중 밀집 위험도 분석과 고위험 보행로 선정을 위한 수치지형도 기반 3D 모델링)

  • Jae Min Lee;Imgyu Kim;Sang Yong Park;Hyuncheol Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.87-95
    • /
    • 2023
  • On October 29, 2022, a very large number of people gathered in Itaewondong, Yongsan-gu, Seoul, Korea for a Halloween festival, and as crowds pushed through narrow alleys, 159 deaths and 195 injuries occurred, making it the largest crushing incident in Korea. There have been a number of stampede deaths where crowds gathered at large-scale festivals, event venues, and stadiums, both at home and abroad. When the density increases, the physical contact between bodies becomes very strong, and crowd turbulence occurs when the force of the crowd is suddenly added from one body to another; thus, the force is amplified and causes the crowd to behave like a mass of fluid. When crowd turbulence occurs, people cannot control themselves and are pushed into he crowd. To prevent a stampede accident, investigation and management of areas expected to be crowded and congested must be systematically conducted, and related ministries and local governments are planning to establish a crowd management system to prepare safety management measures to prevent accidents involving multiple crowds. In this study, based on national data, a continuous digital topographic map is modeled in 3D to analyze the risk of crowding and present a plan for selecting high-risk walking routes. Areas with a high risk of crowding are selected in advance based on various data (numerical data, floating population, and regional data) in a realistic and feasible way, and the analysis is based on the visible results from 3D modeling of the risk area. The study demonstrates that it is possible to prepare measures to prevent cluster accidents that can reflect the characteristics of the region.

A study on the ideal structure of feed sprue in the investment casting process (정밀주조 프로세스에서 피드 스프루의 이상적 구조에 관한 연구)

  • Lee, Kwang-Yeol
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.2
    • /
    • pp.105-113
    • /
    • 2012
  • Maintenance training is generally provided to teach employees new knowledge and techniques in order to increase their qualities. It means that the purpose of maintenance training is to increase an employee's knowledge or technique level and to maintain or increase their performance level through continuous training in their field, and the methods, contents and the level of training vary depending on the type of job they perform. Maintenance training is more important for jobs that require continuous technical increases or research, or for professional jobs that continuously require new knowledge and techniques. The purpose of this study is to provide quality service to consumers by responding to the rapidly changing jewelry distribution environment and to quickly and accurately acquire new and advanced jewelry inspection and appraisal techniques, and to contribute to the healthy consumption culture through a general quality increase in the jewelry industry.

Application of Open-source OpenFOAM for Simulating Combustion and Heating Performance in Horizontal CGL Furnace (수평형 CGL 소둔로의 연소 및 가열 성능 해석을 위한 오픈소스 OpenFOAM 기반 전산유체 해석)

  • Kim, GunHong;Oh, Kyung-Teak;Kang, Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.553-561
    • /
    • 2017
  • The main motivation for this study was to establish a CFD-based procedure for the analysis of heating characteristics, particularly in industrial furnaces. As certain open-source software packages have gained popularity in dealing with complex industrial problems, the OpenFOAM framework was selected for further development of advanced physical models to meet industrial requirements. In this study, the newly developed comprehensive model was applied to simulate physical processes in the full-scale horizontal furnace of a continuous galvanizing line (CGL). The numerical results obtained indicate that the current approach predicts heating characteristics reasonably well. It was also found that radiative heat transfer plays a dominant role in heating the moving strip. To improve the predictability of our method, further work is required to model the turbulence-chemistry interaction realistically, as well as to impose a physically correct thermal wall boundary condition.

Fabrication of Three-Dimensional Scanning System for Inspection of Massive Sinkhole Disaster Sites (대형 싱크홀 재난 현장 조사용 3차원 형상화 장비 구현)

  • Kim, Soolo;Yoon, Ho-Geun;Kim, Sang-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.341-349
    • /
    • 2020
  • Recently, interest in ground subsidence in urban areas has increased after a large sinkhole occurred near the high-story building area in Jamsil, Seoul, Korea, in 2014. If a massive sinkhole occurs in an urban area, it is crucial to assess its risk rapidly. Access to humans for on-site safety diagnosis may be difficult because of the additional risk of collapse in the disaster area. Generally, inspection using drones equipped with high-speed lidar sensors can be utilized. However, if the sinkhole is created vertically to a depth of 100 m, similar to the sinkhole in Guatemala, the drone cannot be applied because of the wireless communication limit and turbulence inside the sinkhole. In this study, a three-dimensional (3D) scanning system was fabricated and operated using a towed cable in a massive vertical sinkhole to a depth of 200 m. A high-speed lidar sensor was used to obtain a continuous cross-sectional shape at a certain depth. An inertial-measuring unit was applied to compensate for the error owing to the rotation and pendulum movement of the measuring unit. A reconstruction algorithm, including the compensation scheme, was developed. In a vertical hole with a depth of 180 m in the mining area, the fabricated system was applied to scan 0-165 m depth. The reconstructed shape was depicted in a 3D graph.

Flicker Mitigation in a Wind Farm by Controlling a Permanent Magnet Synchronous Generator (영구자석형 동기발전기를 이용한 풍력단지의 플리커 저감)

  • Hoan, Pham Van;Kim, Dae-Hyun;Ahn, Jin-Hong;Kim, Eel-Hwan;Oh, Seong-Bo;Kim, Ho-Chan;Kim, Se-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1163-1168
    • /
    • 2009
  • The power quality of wind energy becomes more and more important in connecting wind-farms to the grid, especially weak grid. This paper presents the simulation of a wind farm of a permanent magnet synchronous generator (PMSG) and a doubly fed induction generator (DFIG). Flicker mitigation is performed by using PMSG as a static synchronous compensator (STATCOM) to regulate the voltage at the point of common coupling (PCC). A benefit of the measure is that integrating two function of to control the active power flow and to reduce the voltage flicker in a wind farm. Simulation results show that controlling PMSG is an effective and economic measure in reducing the flicker during continuous operation of grid connected wind turbines regardless of short circuit capacity ratio, turbulence intensity and grid impedance angle.

Numerical Simulation of Air Contaminant Dispersion around Urban City (도심지 빌딩주변 자동차 배가스 분산에 관한 연구)

  • Yu, Kyung-Seok;Ryu, Il-Kwang
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.2 s.60
    • /
    • pp.11-19
    • /
    • 2006
  • Ran numerical analysis about simplicity warm current model (simple turbulence model) to examine closely distributed laying stress on NOx of contaminant that happen in downtown that building is massed and result is as following. Downtown building is massed and transfer of vehicles can know that frequent area receives greatly effect of building. Pollution displays class kind phenomenon striking in the building, class kind done pollution that show high density being mixed with pollution that happen in vehicles being flowed in again side know can. Divide velocity vector of pollution and density change to ancient city and did numerical analysis. Because NOx is flowed in diversion of water neighborhood by continuous this kind in Godo 20m point, density showed density of $0.0907mg/m^3s$, and can know that Banryuhyeon that Pollution strikes in the building at ancient city 30m point is decreased and approaches with freedom flowing without cooperation (cavity) phenomenon remarkably. Because pollution strikes in the building at distance shaft 383m point, class kind do phenomenon that know appeared notedly Nopeungeonmulgwanat between building pollution density $0.067mg/m^3$ head of a families high appear.

Monte Carlo simulation for the response analysis of long-span suspended cables under wind loads

  • Di Paola, M.;Muscolino, G.;Sofi, A.
    • Wind and Structures
    • /
    • v.7 no.2
    • /
    • pp.107-130
    • /
    • 2004
  • This paper presents a time-domain approach for analyzing nonlinear random vibrations of long-span suspended cables under transversal wind. A consistent continuous model of the cable, fully accounting for geometrical nonlinearities inherent in cable behavior, is adopted. The effects of spatial correlation are properly included by modeling wind velocity fluctuation as a random function of time and of a single spatial variable ranging over cable span, namely as a one-variate bi-dimensional (1V-2D) random field. Within the context of a Galerkin's discretization of the equations governing cable motion, a very efficient Monte Carlo-based technique for second-order analysis of the response is proposed. This procedure starts by generating sample functions of the generalized aerodynamic loads by using the spectral decomposition of the cross-power spectral density function of wind turbulence field. Relying on the physical meaning of both the spectral properties of wind velocity fluctuation and the mode shapes of the vibrating cable, the computational efficiency is greatly enhanced by applying a truncation procedure according to which just the first few significant loading and structural modal contributions are retained.

Wind Flow over Hilly Terrain (언덕지형을 지나는 유동에 관한 연구)

  • 임희창;김현구;이정묵;경남호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.459-472
    • /
    • 1996
  • An experimental investigation on the wind flow over smooth bell-shaped two-dimensional hills with hill slopes (the ratio of height to half width) of 0.3 and 0.5 is performed in an atmospheric boundary-layer wind tunnel. Two categories of the models are used in the present investigation; six two-dimensional single-hills, and four continuous double-hills. The measurements of the flow field and surface static-pressure distribution are carried out over the Reynolds number (based on the hill height) of 1.9 $\times 10^4, 3.3 \times 10^4, and 5.6 \times 10^4$. The velocity profiles and turbulence characteristics are measured by the pitot-tube and X-type hot-wire anemometer, respectively. The undisturbed boundary-layer profile on the bottom surface of the wind tunnel is reasonably consistent with the power-law profile with $\alpha = 7.0 (1/\alpha$ is the power-law exponent) and shows good spanwise uniformities. The profiles of turbulent intensity are found to be consistent along the centerline of the wind tunnel. The measured non-dimensional speed-up profiles at the hill crest show good agreements with the predictions of Jackson and Hunt's linear theory. The flow separation occurs in the hill slope of 0.5, and the oil-ink dot method is used to find the reattachment points in the leeside of the hill. The measured reattachment points are compared with the numerical predictions. Comparisons of the mean velocity profiles and surface pressure distributions between the numerical predictions and the experimental results show good agreements.

  • PDF

Use of laminar flow water storage tank (LFWS) to mitigate the membrane fouling for reuse of wastewater from wafer processes

  • Sun, Darren Delai;Wu, You
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.221-230
    • /
    • 2012
  • This study employed the modified fouling index (MFI) to determine the performance of a two-step recycling system - a membrane filtration integrated laminar flow water storage (LFWS) tank followed by an ion exchange process to reclaim ultrapure water (UPW) from the wastewater generated from semiconductor wafer backgrinding and sawing processes. The first step consisted of the utilization of either ultrafiltration (UF) or nanofiltration (NF) membranes to remove solids in the wastewater where the second step consisted of an ion exchanger to further purify the filtrate. The system was able to produce high purity water in a continuous operating mode. However, higher recycling cost could be incurred due to membrane fouling. The feed wastewater used for this study contained high concentration of fine particles with low organic and ionic contents, hence membrane fouling was mainly attributed to particulate deposition and cake formation. Based on the MFI results, a LFWS tank that was equipped with a turbulence reducer with a pair of auto-valves was developed and found effective in minimizing fouling by discharging concentrated wastewater prior to any membrane filtration. By comparing flux behaviors of the improved system with the conventional system, the former maintained a high flux than the latter at the end of the experiment.

Numerical Analysis for the Air-Side Convective Heat Transfer Characteristics in a Compact Heat Exchanger with Flat Tubes and Plate Fins According to the Aspect Ratio (종횡비에 따른 납작관-평판휜 형상의 밀집형 열교환기 내공기 측 대류열전달특성에 대한 수치해석)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.695-703
    • /
    • 2008
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in a compact heat exchanger with flat tubes and continuous plate fins according to the aspect ratio. RNG k-$\varepsilon$ model is applied for turbulence analysis. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous correlations for circular tubes. The numerical conditions are considered for the aspect ratios ranging from 3.06 to 5.44 and Reynolds number ranging from 1000 to 10,000. The results showed that heat transfer coefficients decreased with the increase of aspect ratio. From the calculated results a correlation of Colburn j factor for the considered aspect ratio in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.