• Title/Summary/Keyword: Continuous Positive Airway Pressure

Search Result 86, Processing Time 0.025 seconds

Pulmonary hypertension due to obstructive sleep apnea in a child with Rubinstein-Taybi syndrome

  • Choi, Hyung Soon;Yu, Jeong Jin;Kim, Young-Hwue;Ko, Jae-Kon;Park, In-Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.6
    • /
    • pp.212-214
    • /
    • 2012
  • Rubinstein-Taybi syndrome (RTS) is characterized by peculiar facies, mental retardation, broad thumbs, and great toes. Approximately one-third of the affected individuals have a variety of congenital heart diseases. They can also have upper airway obstruction during sleep, due to hypotonia and the anatomy of the oropharynx and airway, which make these patients susceptible to obstructive sleep apnea (OSA). In our case, pulmonary hypertension was caused, successively, by congenital heart defects (a large patent ductus arteriosus and arch hypoplasia) and obstructive sleep apnea during early infancy. The congenital heart defects were surgically corrected, but persistent pulmonary hypertension was identified 2 months after the operation. This pulmonary hypertension was due to OSA, and it was relieved by nasal continuous positive airway pressure. This case is the first report of pulmonary hypertension from OSA in a young infant with RTS.

Incidence and Associated Factors of Pressure Ulcers in Newborns (신생아의 욕창발생실태 및 관련요인)

  • Choi, Won-Young;Ju, Hyeon-Ok
    • Child Health Nursing Research
    • /
    • v.18 no.4
    • /
    • pp.177-183
    • /
    • 2012
  • Purpose: This study was done to examine the incidence of pressure ulcers and associated factors, by inspecting the skin of newborn babies in a newborn unit or newborn intensive care unit (NICU). Methods: The participants were 101 newborn babies in either a newborn unit or NICU in D general hospital. The incidence of pressure ulcer was measured using the skin inspection tool for pressure ulcer, suggested by Agency for Health Care Policy and Research. Results: Incidence rate of pressure ulcer was 19.8%, and 80% of the newborns with pressure ulcers were premature babies. The commonest region of onset was the ear (36.8%), followed by the foot (31.6%), occipital region (15.8%) and knee (15.8%). Those are the regions related to external medical devices like nasal Continuous Positive Airway Pressure and Pulse Oximetry. Factors related to pressure ulcers were gestational period of 37 weeks or less, hospitalization for 7 days or more, birth weight under 2,500 g and a low level of serum albumin. Conclusion: The results of the study show that the skin and underlying tissues of premature infants is at risk for pressure-related skin breakdown. As most pressure ulcers are caused by medical devices, nursing interventions are required to prevent further aggravation of the lesions.

Case of Treatment Using Adaptive Servo-Ventilation in a Patient with Central Sleep Apnea after a Lateral Medullary Infarction (외측 연수 경색에 의해 발생한 중추성 수면 무호흡 환자의 자동-적응형 양압기를 사용하여 치료한 경험)

  • Kim, Dae Jin;Cho, Jae Wook;Kim, Hyun Woo;Choi, Jeong Su;Mun, Sue Jean
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.278-283
    • /
    • 2020
  • Central sleep apnea (CSA) is characterized by respiratory failure of at least 10 seconds without any effort of the chest and abdomen in the absence of upper airway resistance during sleep. In this case, the patient experiences respiratory failure that does not meet the CSA diagnostic criteria and CSA symptoms. Magnetic resonance imaging diffusion-weighted imaging (MRI DWI) scans revealed a lateral medullary infarction. Continuous positive airway pressure (CPAP) was applied as a primary treatment for CSA and respiratory failure. During the titration of CPAP, the apnea-hypopnea index (AHI) and arousal index (AI) were worse than the results before its use (AHI: 42.5/hr→82.8/hr, AI: 21.7/hr→40.8h). As a result, adaptive servo-ventilation (ASV) was chosen as the secondary treatment. Compared to the night-polysomnography results before the ASV treatment, the AHI improved (42.5/hr→8.6/hr). Therefore, ASV is a potential treatment for CSA and respiratory failure in these patients.

Classification of Sleep/Wakefulness using Nasal Pressure for Patients with Sleep-disordered Breathing (비강압력신호를 이용한 수면호흡장애 환자의 수면/각성 분류)

  • Park, Jong-Uk;Jeoung, Pil-Soo;Kang, Kyu-Min;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.127-133
    • /
    • 2016
  • This study proposes the feasibility for automatic classification of sleep/wakefulness using nasal pressure in patients with sleep-disordered breathing (SDB). First, SDB events were detected using the methods developed in our previous studies. In epochs for normal breathing, we extracted the features for classifying sleep/wakefulness based on time-domain, frequency-domain and non-linear analysis. And then, we conducted the independent two-sample t-test and calculated Mahalanobis distance (MD) between the two categories. As a results, $SD_{LEN}$ (MD = 0.84, p < 0.01), $P_{HF}$ (MD = 0.81, p < 0.01), $SD_{AMP}$ (MD = 0.76, p = 0.031) and $MEAN_{AMP}$ (MD = 0.75, p = 0.027) were selected as optimal feature. We classified sleep/wakefulness based on support vector machine (SVM). The classification results showed mean of sensitivity (Sen.), specificity (Spc.) and accuracy (Acc.) of 60.5%, 89.0% and 84.8% respectively. This method showed the possibilities to automatically classify sleep/wakefulness only using nasal pressure.

Respiratory support with heated humidified high flow nasal cannula in preterm infants

  • Jeon, Ga Won
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.10
    • /
    • pp.389-394
    • /
    • 2016
  • The incidence of bronchopulmonary dysplasia (BPD) has not decreased over the last decade. The most important way to decrease BPD is by weaning the patient from the ventilator as soon as possible in order to reduce ventilator-induced lung injury that underlies BPD, and by using a noninvasive ventilator (NIV). Use of a heated, humidified, high flow nasal cannula (HHHFNC), which is the most recently introduced NIV mode for respiratory support in preterm infants, is rapidly increasing in many neonatal intensive care units due to the technical ease of use without sealing, and the attending physician's preference compared to other NIV modes. A number of studies have shown that nasal breakdown and neonatal complications were lower when using a HHHFNC than when using nasal continuous positive airway pressure (nCPAP), or nasal intermittent positive pressure ventilation. The rates of extubation failure during respiratory support were not different between patients who used HHHFNC and nCPAP. However, data from the use of HHHFNC as the initial respiratory support "after birth", particularly in extremely preterm infants, are lacking. Although the HHHFNC is efficacious and safe, large randomized controlled trials are needed before the HHHFNC can be considered an NIV standard, particularly for extremely preterm infants.

Antisnoring Effects of Adjustable Anterior Positioner: Case Study (조절성 전방이동형 코골이 방지장치의 효과)

  • Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.213-219
    • /
    • 2012
  • Oral appliances are a primary treatment option for snoring and mild to moderate obstructive sleep apnea (OSA) and are considered as an alternative for patients with severe OSA who have failed continuous positive airway pressure (CPAP) or upper airway surgery. But it is true that OAs have varying degrees of effectiveness depending on different oral appliances and the efficacy of OAs are established in some but not all patients. New oral appliance, which is one of Adjustable Anterior Positioners, was developed by Dept of Oral Medicine, Dental School, Dankook University. This is a report for treating severe OSA patient with a failure of previous uvulopalatopharyngoplasty using a new Adjustable Anterior Positioner, followed by significant success of controlling OSA.

Nasal Continuous Airway Pressure Titration Unmasks Periodic Limb Movements in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술에 따른 주기성 사지운동증의 표출)

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.1
    • /
    • pp.103-110
    • /
    • 1998
  • Objectives : High co-morbidity of periodic limb movements during sleep(PLMS) and obstructive sleep apnea syndrome(OSAS) is well known and their incidences tend to increase in the elderly. Previous studies have inconsistently rep0l1ed increase or no change of periodic limb movement index(PLMI) by nasal continuous positive airway pressure(CPAP) in OSAS without analyzing possible variables affecting PLMI. We attempted to examine PLMI change evoked during CPAP titration and also factors affecting it in OSAS. Methods : Twenty-nine OSAS patients(M:F=26:3, mean age: $51.6{\pm}10.6\;yrs$) without other sleep disorders except for PLMS were selected, based on the nocturnal (baseline) polysomnograhy. Another night of noctumal polysomnography was performed for CPAP pressure titration. We compared between those two nights PLMI, mean and lowest $SaO_2$, and sleep variables. We also calculated PLMI differences between baseline and CPAP nights, named as delta PLMI (value of CPAP night PLMI minus value of baseline night PLMI). Correlations were calculated between delta PLMI and factors such as age, body mass index, applied CPAP pressure, baseline night values of respiratory disturbance index, mean and lowest $SaO_2$, and sleep parameter differences between baseline and CPAP nights. Results : Decrease of RDI(p<.01) and increase in mean and lowest $SaO_2$ (p<.05, p<.01) were observed during CPAP night. No sleep parameters showed significant change except for the decrease of total stage 1 sleep%(p<.01) during CPAP night. Ten out of 29 patients showed PLMI increase, while the other 19 patients showed either no change(n=14) or even PLMI decrease(n=5) during CPAP night. The 10 patients showing PLMI increase during CPAP night showed a significant positive correlation between delta PLMI and baseline night RDI(p<.05), which meant that PLMI increase was found to be more prominent in higher RDI patients than in lower RDI ones. There were no significant correlations between delta PLMI and other factors in the other 19 patients. Conclusions : We suggest that during the baseline night PLMS would have been underscored and/or masked due to the overlapping of PLMS and apneas/hypopneas or the arousals induced by apneas/hypopneas. Despite its still unknown mechanism, the CPAP application may unmask PLMS and increase PLMI in a subgroup of OSAS patients. It needs to be evaluated further whether the chronic CPAP use sustains the above finding.

  • PDF

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

Effects of Nasal Continuous Positive Airway Pressure Application on Sympathetic Activation : Power Spectrum Analysis of Electrocardiogram in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술 시행이 교감신경계 활성도에 끼치는 영향 : 심전도 스펙트럼 분석)

  • Youn, Tak;Park, Hae-Jeong;Kim, Eui-Joong;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • Objectives: Obstructive sleep apnea syndrome(OSAS) is known to be associated with the changes of autonomic nervous system (ANS). Nasal continuous positive airway pressure(nCPAP) treatment was found to correct abnormal ANS changes in OSAS but it remains to be further clarified. We aimed to assess the effects of nCPAP on ANS manifested on electrocardiogram, using spectrum analysis in the subjects with OSAS. Methods: Digital polysomnography was performed in 18 patients with OSAS(mean age $43.7{\pm}16.6$ years ; 17 males, 1 female ; mean respiratory disturbance index (RDI) $48.6{\pm}20.9$) for one baseline and another CPAP nights. From each night, 300 continuous beats of ECGs without artifact were chosen from both stage 2 sleep and REM sleep and they were used for power spectrum analysis. We compared between baseline and CPAP nights the heart rate variability including VLF(very low frequency power), LF (low frequency power), HF(high frequency power), R-R means, R-R variance, and LF/HF ratio, using Wilcoxon signed ranks test. Results: In all patients, nCPAP proved to be effective in relieving apneas and snoring. During nCPAP night compared with baseline night, decreases in VLF(p<0.05), LF(p<0.01), and R-R variance(p<0.05) were found in stage 2 sleep, and decreased LF(p<0.05) was found in REM sleep. No significant differences in each sleep stage were found in other variables between the two nights. Conclusion: Our findings suggest that OSAS increases the activity of sympathetic nervous system and nCPAP application effectively decreases the activity. And nCPAP does not appear to influence the parasympathetic nervous activity in OSAS.

  • PDF

Diagnosis and Treatment of Sleep Apnea (수면무호흡증의 진단과 치료)

  • Lee, Sang-Haak;Moon, Hwa-Sik
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 2003
  • Sleep apnea syndrome is a common clinical disorder characterized by intermittent cessation of airflow at nose and mouth during sleep. The clinical significance of this syndrome is that it is one of the most common causes of excessive daytime sleepiness. It can also cause neuropsychiatric, cardiovascular, and cerebrovascular complications. The standard for diagnosis of sleep apnea syndrome is nocturnal polysomnography. Because polysomnography is a time-consuming and expensive test, many efforts have been made to replace polysomnography with a simpler system of monitoring, but no method has yet been approved as a definitive investigation method. The goals of treatment for this syndrome are to eliminate excessive daytime sleepiness and to reduce the risk of possible cardiovascular complications. Continuous positive airway pressure is the most definite and widely accepted treatment for achieving these goals. Other treatments such as surgical treatment, oral appliances, and behavioral therapy may be useful for selected patients who are mildly affected.