• 제목/요약/키워드: Continuous Device

검색결과 592건 처리시간 0.026초

영상장치 센서 데이터 QC에 관한 연구 (A study on imaging device sensor data QC)

  • 윤동민;이재영;박성식;전용한
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Failure Prediction of Metal Oxide Varistor Using Nonlinear Surge Look-up Table Based on Experimental Data

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.317-322
    • /
    • 2015
  • The metal oxide varistor (MOV) is a major component of the surge protection devices (SPDs) currently in use. The device is judged to be faulty when fatigue caused by the continuous inflow of lightning accumulates and reaches the damage limit. In many cases, induced lightning resulting from lightning strikes flows in to the device several times per second in succession. Therefore, the frequency or the rate at which the SPD is actually exposed to stress, called a surge, is outside the range of human perception. For this reason, the protective device should be replaced if it actually approaches the end of its life even though it is not faulty at present, currently no basis exists for making the judgment of remaining lifetime. Up to now, the life of an MOV has been predicted solely based on the number of inflow surges, irrespective of the magnitude of the surge current or the amount of energy that has flowed through the device. In this study, nonlinear data that shows the damage to an MOV depending on the count of surge and the amount of input current were collected through a high-voltage test. Then, a failure prediction algorithm was proposed by preparing a look-up table using the results of the test. The proposed method was experimentally verified using an impulse surge generator

Real-Time Detection of Residual Free Chlorine and pH in Water Using a Microchannel Device

  • Kim, Sam-Hwan;Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.368-374
    • /
    • 2011
  • A microfluidic device for real-time monitoring of residual free chlorine and pH in water based on optical absorption is proposed. The device consists of a serpentine micromixer for mixing samples with a reagent, and a photodiode and light emitting diode(LED) for the detection of light absorbance at specific wavelengths, determined for specific reagent combinations. Spectral analyses of the samples mixed with N, N'-diethyl-p-phenylenediamine(DPD) reagent for chlorine determination and bromothymol blue(BTB) for pH measurement are performed, and the wavelengths providing the most useful linear changes in absorbance with chlorine concentration and pH are determined and used to select the combination of LED and photodiode wavelengths for each analyte. In tests using standard solutions, the device is shown to give highly reproducible results, demonstrating the feasibility of the device for the inexpensive and continuous monitoring of water quality parameters with very low reagent consumption.

원 스테이션 파스너 자동포장기 개발(I): 패킹 메커니즘의 최적설계 (Development of Automatic Packing System of One Station for Fasteners(I): Optimization Design of Packing Mechanism)

  • 김용석;정찬세;양순용
    • 한국생산제조학회지
    • /
    • 제20권3호
    • /
    • pp.335-341
    • /
    • 2011
  • In this paper, we proposed an automatic packing mechanism of one station concept for fastener objects where the continuous work is performed in a finite space. The proposed packing mechanism is composed of supporting frame, feeding supply, air shower device, clamping/opening device, batch charging device, sealing/cutting device and supply adjusting device. And, these mechanisms have been modularized through mechanical, dynamical, structural and fluid optimized design using the SMO(SimDesigner Motion) analysis module. Also, the virtual prototype was carried out using the 3-D CAD program. The packing process is consisted performed in the order of feeding, clamping, bottom sealing, cutting, opening, object charging, closing and the upper sealing. And the time of these cycles were designed to be completed in 15-20 seconds. This packing mechanism will be created as a prototype in the near future. In addition, it will be applied to the production scenes after going through a field test for the validation of performance.

Electro-optical devices from polymer-stabilized liquid crystals with molecular shape polarity

  • Kim, Sang-Hwa;Chien, Liang Chy;Komitov, Lachezar
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.839-842
    • /
    • 2004
  • We present a fast-switching electro-optical device based on flexoelectro-optic effect in short pitch cholesterics oriented in uniform lying helix texture. The device has two operating modes: amplitude and phase modulation mode. The amplitude modulation mode is a fast in-plane switching of the device optic axis that enables to achieve a high percent of modulation of the transmitted light intensity whereas the phase mode gives a continuous change of the refractive index and thus of the phase shift of the transmitted light. By using a small concentration of diacrylate monomer and selecting the illumination conditions we have been able to create a inhomogeneous polymeric network mostly localized at both substrate surfaces and stabilize the two switching modes.

  • PDF

후막 전계 발광 소자의 Carbon과 Silver 전극 특성 (Carbon and Silver Electrode Properties of Power Electroluminescent Device)

  • 이종찬;성현호;조황신;박용규;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.26-30
    • /
    • 2000
  • In this paper, carbon and silver electrode properties of power electroluminescent device were investigated. Devices were manufactured by screen-printing and manufactured devices were measured following things with variable applied voltage; emission spectra, transferred charge density, brightness and current. A continuous test at $65 ^{\circ}C$ of temperature and 95% of humidity was operated. The brightness of devices which were made of silver and carbon electrode at 100V was $67.03cd/m^2$ and $60.02cd/m^2$ respectively. In case of device, which was made of silver electrode, a black spot was formed after 72 hours and degraded but carbon electrode was stable.

  • PDF

Single Mode Laser Oscillation in an Nd-Doped Large Core Double Clad Fiber Cavity with Concatenated Adiabatic Tapers

  • Seo, Hong-Seok;Choi, Yong-Gyu;Kim, Kyung-Hon;Jeong, Hoon;Oh, Kyung-Hwan
    • ETRI Journal
    • /
    • 제24권3호
    • /
    • pp.255-258
    • /
    • 2002
  • We created a new design for an Nd-doped clad-pumped silica fiber laser to enhance the pump absorption and lasing efficiency for a butt-coupled, end-pumped scheme. Two concatenated adiabatic tapers formed within the laser cavity simultaneously removed higher order modes and were spliced to conventional single mode fibers. We theoretically analyzed mode propagation along the composite cavity and experimentally achieved continuous wave oscillation in the $LP_{01}$ mode at $1.06\;{\mu}m$ and a laser output power of over 820 mW with a slope efficiency of 27%.

  • PDF

능동형 임플란터블 디바이스 기술동향: BCI 응용 중심 (Active Implantable Device Technology Trend: BCI Application Focus)

  • 이성규;변춘원;김이경;박형일
    • 전자통신동향분석
    • /
    • 제32권6호
    • /
    • pp.27-39
    • /
    • 2017
  • A variety of medical devices are utilized to repair or help injured body functions after accidental injury(such as a traffic accident), population aging, or disease. Such medical devices are being actively researched and developed in portable form, skin patchable type, and further, implantable form. In the future, active implantable medical devices for neuro and brain sciences are expected to be developed. Active implantable medical devices that detect brain signals and control neurology for a wider understanding of human cognition and nerve functions, and for an understanding and treatment of various diseases, are being actively pursued for future use. In this paper, the core elements of implantable devices that can be applied to neuro and brain sciences are classified into electrode technologies for bio-signal acquisition and stimulation, analog/digital circuit technologies for signal processing, human body communication technologies, wireless power transmission technologies for continuous device use, and device integration technologies to integrate them. In each chapter, the latest technology development trends for each detailed technology field are reviewed.

A Direct Single-phase Quasi-resonant AC-AC Converter with Zero Voltage Switching

  • Antchev, Mihail Hristov
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.860-873
    • /
    • 2017
  • The present article reports an analysis and investigation of a direct AC-AC quasi-resonant converter. A bidirectional power device, whose switching frequency is lower than the frequency of the current passing through the load, is used for its realization. The zero voltage switching mode is described when zero voltage on the power device is available by measuring it with the control system. The continuous current in the resonant inductance by switching the power device at zero voltage is considered, and it is characterized by two sub-modes. A mathematical analysis of the processes has been made and comparative results from the computer simulation and experimental study have been brought. The converter can be used in a wide areas of power electronics: induction heating, wireless power transfer, AC-DC converters, etc.

Industrial scale extraction and stripping devices for continuous recovery of gallic acid from Chinese nutgall processing wastewater

  • Wu, Yundong;Xia, Xihe;Dong, Shuyu;Zhou, Kanggen
    • Environmental Engineering Research
    • /
    • 제22권3호
    • /
    • pp.288-293
    • /
    • 2017
  • In this study, we report the industrial application of an efficient technology for the recovery of gallic acid from Chinese nutgall processing wastewater. The recovery of gallic acid by industrial scale extraction and stripping devices was performed, with tributyl phosphate as the extractant and kerosene as the diluent. The results showed that the theoretical extraction stage was four, while the theoretical stripping stage was two. A closed-cycle system was studied for the continuous countercurrent extraction and stripping, with a five-stage extraction device and a three-stage reflux stripping device. The results showed that the multistage extraction-stripping system could steadily run for a long period, the average gallic acid level in the raffinate was $0.85g{\cdot}L^{-1}$, and the gallic acid content recovered in the strip liquor was higher than $120g{\cdot}L^{-1}$. The average extraction yield of gallic acid was 94.14%. When the strip liquor was used as raw material for production, the average production yield increased by 8.64%. In addition, after extraction, the $COD_{Cr}$ in the wastewater decreased by 38.19%, and the biodegradability of wastewater improved by 1.6 times. This study provided a new impetus for the sustainable development of the Chinese nutgall processing industry.