• Title/Summary/Keyword: Continuous Device

Search Result 592, Processing Time 0.024 seconds

Strengthening Efficiency for the Various Corner Shapes of RC Member confined with Continuous Fiber Sheets (연속섬유 시트로 보강된 RC 부재의 모서리 형상에 따른 보강 효율에 관한 연구)

  • Ko, Hune-Bum;Lee, Jin-Seop
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.113-119
    • /
    • 2008
  • Recently, fiber reinforced polymers(FRP) composite materials are used extensively in the rehabilitation of concrete structural members. A main application is to wrap beams and columns using the continuous fibers sheets to improve their strength and ductility. The corner chamfering affects significantly the performance of the continuous fibers sheets, and could lead to environmental problem with waste and dust. The main purpose of this paper is to verify the effect of corner conditions on the strength of the continuous fiber sheets, and to introduce new attached components which can avoid environmental problem. A total of 15 specimens were tested and carefully checked for three types of continuous fiber sheets(carbon, glass, and aramid) and three types of corner conditions(non-chamfering, chamfering, and device attaching). It is proved that the devices proposed in this research have some capabilities to use for RC member. But additional research will be needed for commercializing.

Software Risk Management and Cyber Security for Development of Integrated System Remotely Monitoring and Controlling Ventilators (인공호흡기 원격 통합 모니터링 및 제어 시스템 개발을 위한 소프트웨어 위험관리 및 사이버보안)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.99-108
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.

Strategic Approach to Privacy Calculus of Wearable Device User Regarding Information Disclosure and Continuance Intention

  • Cho, Ji Yeon;Ko, Daesun;Lee, Bong Gyou
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.7
    • /
    • pp.3356-3374
    • /
    • 2018
  • The healthcare and fitness wearable-device market is considered as the driving force of the entire wearable device market. However, there are concerns with respect to information privacy because wearable devices constantly collect sensitive data such as individuals' health information. Thus, there is a need for a comprehensive understanding from the perspective of information privacy concerns and related behavior. This study investigates factors considered in the privacy calculus of wearable fitness devices, and verifies differences obtained by the privacy calculus process according to the frequency of exercise. The results obtained from a survey of 248 undergraduate students in Korea revealed that service providers should consider users' interests and exercise characteristics in order to mitigate their privacy concerns and encourage continuous use of wearable devices. This study provides useful insights pertaining to users of wearable fitness devices, and targets researchers and practitioners.

Design and Implementation of a Motor Power Change Speed Device for Micro-controller (Micro-controller 방식에 의한 Motor Power 변속장치의 설계와 구현)

  • 김정래
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.3
    • /
    • pp.163-169
    • /
    • 2003
  • This study was carried out develope a motor power change speed device of motor by used micro- controller. This system was producted a auto-change speed device which switching frequency was 1,000MHz by used a auto- controller. It had a continuous output current such as 5A, 11A, 25A, 35A, 50A. It used a variable voltage from 9V to 18V(Maximum). We designed hardware of and software of micro-controller, we are made up of a auto cut-off function by 3.7V for detected power-loss prevention.

  • PDF

Analysis on the Status and Needs of Training in Assistive Technology of Pediatric Physical Therapist and Pediatric Occupational Therapist (소아물리치료사와 소아작업치료사의 보조공학 교육훈련 실태 및 요구 분석)

  • Kim, Kyoung-A;Jeong, Dong-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.1
    • /
    • pp.99-109
    • /
    • 2013
  • PURPOSE: This study was designed to evaluate the current state of training in assistive technology(AT) for pediatric physical therapists(PPTs) and pediatric occupational therapists(POTs), in addition, investigate therapists' preferred training methods and contents. The eventual purpose was to suggest the essential fundamental factors to adapt the assistive technology in clinics. METHODS: The subject of this study were 167 therapists(98 PPTs and 69 POTs) who work at general hospitals, welfare center, facilities for the disabled, and special education school in Seoul and Gyeonggi province. Frequency analysis and Chi-squared test were used. RESULTS: Significant numbers of PPTs(66 therapists, 67.3%) and POTs(50 therapists, 72.5%) answered that they had received training in AT. More than 48% answered no training experience or low adequacy in each classification scheme for questions. The most difficulty in the training was indicated by lack of education opportunity(90 therapists, 53.9%). The most required device training was seating and position device training(43 therapists, 21.9%) for PPTs and orthosis and prosthesis device training(29 therapists, 21.0%) for POTs. In assistive technology service, PPTs needed evaluation to AT device training(69 therapists, 35.2%) and POTs needed evaluation to disabilities for AT training(41 therapists, 29.7%). Both therapists answered that the most effective training is continuous education(52 therapists, 31.1%) and college education(48 therapists, 28.7%). CONCLUSION: Our findings indicate that PPTs and POTs need more opportunities for training in AT. For effective clinical app lication of AT, there should be continuous education such as on-the-job training, mentoring program, technical manual, and college education.

Surgical Outcomes of Centrifugal Continuous-Flow Implantable Left Ventricular Assist Devices: Heartmate 3 versus Heartware Ventricular Assist Device

  • Kinam Shin;Won Chul Cho;Nara Shin;Hong Rae Kim;Min-Seok Kim;Cheol Hyun Chung;Sung-Ho Jung
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.184-194
    • /
    • 2024
  • Background: Left ventricular assist devices (LVADs) are widely employed as a therapeutic option for end-stage heart failure. We evaluated the outcomes associated with centrifugal-flow LVAD implantation, comparing 2 device models: the Heartmate 3 (HM3) and the Heartware Ventricular Assist Device (HVAD). Methods: Data were collected from patients who underwent LVAD implantation between June 1, 2015 and December 31, 2022. We analyzed overall survival, first rehospitalization, and early, late, and LVAD-related complications. Results: In total, 74 patients underwent LVAD implantation, with 42 receiving the HM3 and 32 the HVAD. A mild Interagency Registry for Mechanically Assisted Circulatory Support score was more common among HM3 than HVAD recipients (p=0.006), and patients receiving the HM3 exhibited lower rates of preoperative ventilator use (p=0.010) and extracorporeal membrane oxygenation (p=0.039). The overall early mortality rate was 5.4% (4 of 74 patients), with no significant difference between groups. Regarding early right ventricular (RV) failure, HM3 implantation was associated with a lower rate (13 of 42 [31.0%]) than HVAD implantation (18 of 32 [56.2%], p=0.051). The median rehospitalization-free period was longer for HM3 recipients (16.9 months) than HVAD recipients (5.3 months, p=0.013). Furthermore, HM3 recipients displayed a lower incidence of late hemorrhagic stroke (p=0.016). In the multivariable analysis, preoperative use of continuous renal replacement therapy (odds ratio, 22.31; p=0.002) was the only significant predictor of postoperative RV failure. Conclusion: The LVAD models (HM3 and HVAD) demonstrated comparable overall survival rates. However, the HM3 was associated with a lower risk of late hemorrhagic stroke.

Development of Automatic Packing System of One Station for Fasteners(II) : Packing System Manufacture and Performance Test (원 스테이션 파스너 자동포장기 개발(II) : 제작 및 성능검증)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.653-658
    • /
    • 2011
  • In general, the purpose of packaging fasteners is a series of management activities to maintain the condition at the time of production until they get delivered to the end user. An automatic packing system for fasteners is consisted of bucket conveyor, slide feeder, vision inspection system, box-magazine conveyor system and automatic packing machine. Also, the automatic packing machine is consisted of six modules including charging device, clamping/opening device, sealing/cutting device, feeding/air-shower device, supplying/adjusting device and device frame, etc. In this paper, we proposed an automatic packing mechanism of the one station concept for packing work of fastener objects where the continuous batch work is performed in a finite space. The proposed one-station packing mechanism has been optimized through mechanical, dynamical, structural and fluid analyses. And it had been manufactured as the prototype of automatic packing machine. The field test for validation of performance was performed directly at the production line of bolt and screw. In the field test, this packing machine showed an efficiency of about 4.5 times the manual operation. It also showed 30% reduction in the consumption of packing materials compared to the manual operation. This automatic packing machine for fastener objects will be commercialized soon.

Detecting Bladder Biomarkers for Closed-Loop Neuromodulation: A Technological Review

  • Park, Eunkyoung;Lee, Jae-Woong;Kang, Minhee;Cho, Kyeongwon;Cho, Baek Hwan;Lee, Kyu-Sung
    • International Neurourology Journal
    • /
    • v.22 no.4
    • /
    • pp.228-236
    • /
    • 2018
  • Neuromodulation was introduced for patients with poor outcomes from the existing traditional treatment approaches. It is well-established as an alternative, novel treatment option for voiding dysfunction. The current system of neuromodulation uses an open-loop system that only delivers continuous stimulation without considering the patient's state changes. Though the conventional open-loop system has shown positive clinical results, it can cause problems such as decreased efficacy over time due to neural habituation, higher risk of tissue damage, and lower battery life. Therefore, there is a need for a closed-loop system to overcome the disadvantages of existing systems. The closed-loop neuromodulation includes a system to monitor and stimulate micturition reflex pathways from the lower urinary tract, as well as the central nervous system. In this paper, we reviewed the current technological status to measure biomarker for closed-loop neuromodulation systems for voiding dysfunction.

The Innovative Medical Devices Using Big Data and Artificial Intelligence: Focusing on the cases of Korea, the United States, and Europe (빅데이터 및 인공지능을 이용한 혁신의료기기 발전 방향: 한국, 미국, 유럽의 사례중심)

  • Yun Hee Song;Gyu Ha Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.264-274
    • /
    • 2023
  • Purpose: The objective is to extract insights that can contribute to the formulation of harmonized international policies and support measures for innovative medical devices and management systems. This study aims to propose effective strategies for future medical device innovation and healthcare delivery. Results: It investigates technological advancements, regulatory approval systems, insurance policies, and successful commercialization cases in South Korea, the United States, and the European Union. In 2018, the FDA implemented insurance coverage for Software as a Medical Device (SaMD) and recognized insurance coverage for Digital Therapeutics (DTx). Germany is a country that ensures permanent reimbursement for healthcare applications since 2020, making it the first country to provide legal health insurance coverage for fostering a digital ecosystem. Conclusion: The findings of this research highlight the importance of cultivating a supportive regulatory and environmental framework to facilitate the adoption of innovative medical devices. Continuous support for research and development (R&D) efforts by companies, along with the validation of clinical effectiveness, is crucial.

Development of a PLD heater for continuous deposition and growth of superconducting layer

  • Jeongtae Kim;Insung Park;Gwantae Kim;Taekyu Kim;Hongsoo Ha
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.2
    • /
    • pp.14-18
    • /
    • 2023
  • Superconducting layers deposited on the metal substrate using the pulsed laser deposition process (PLD) play a crucial role in exploring new applications of superconducting wires and enhancing the performance of superconducting devices. In order to improve the superconducting property and increase the throughput of superconducting wire fabricated by pulsed laser deposition, high temperature heating device is needed that provides high temperature stability and strong durability in high oxygen partial pressure environments while minimizing performance degradation caused by surface contamination. In this study, new heating device have been developed for PLD process that deposit and growth the superconducting material continuously on substrate using reel-to-reel transportation apparatus. New heating device is designed and fabricated using iron-chromium-aluminum wire and alumina tube as a heating element and sheath materials, respectively. Heating temperature of the heater was reached over 850 ℃ under 700 mTorr of oxygen partial pressure and is kept for 5 hours. The experimental results confirm the effectiveness of the developed heating device system in maintaining a stable and consistent temperature in PLD. These research findings make significant contributions to the exploration of new applications for superconducting materials and the enhancement of superconducting device performance.