• 제목/요약/키워드: Continuous Arrangement

검색결과 103건 처리시간 0.026초

전시디자인의 변천과정과 요인에 관한 연구 - 독립기념관의 시기별 전시변화를 중심으로 - (A Study on Transition Process and factor of Exhibition Design - Based on the Exhibition's Transition in the Independence Hall -)

  • 권순관
    • 한국실내디자인학회논문집
    • /
    • 제15권5호
    • /
    • pp.265-272
    • /
    • 2006
  • Traditionally exhibition design as been restricted to architectural, interior, and lighting design, but recently it has begun to overlap into environmental, performance, and installation art. Exhibition design also increasingly involves the application of film, fashion, and the new media. In the past, exhibits were arranged and displayed for the visitor to view directly, but with the development of more effective exhibit media a connection has been created between the exhibit and the visitor. However exhibition design has reached the limits of continuous growth without background theory, when now it must take Into consideration the museum's activation and the importance of the exhibition's design. Exhibition design has developed and grown rapidly since the Taejeon Expo in 1993, but it is a difficult development without a theoretical structure. The flow of exhibition design must be systemized, as the systemization of the transition process of exhibition design has not yet been achieved. This study aims to present an arrangement of exhibition design flow, and to investigate the variation factors in the transition process of exhibition design and exhibit medium development, based on the 18 year history of the Independence Hall that introduced the first systematic planning of an exhibition in 1987.

초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석 (Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line)

  • 임재섭;신구용;이동일;주문노;양광호
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

양돈장의 소모성질병 확산 분석을 위한 현장 모니터링 및 공기유동학적 분석 (Aerodynamic Approaches for Estimation of Waste Disease Spread in Pig Farm through Airborne Contaminants)

  • 서일환;이인복;문운경;권경석
    • 한국농공학회논문집
    • /
    • 제56권1호
    • /
    • pp.41-49
    • /
    • 2014
  • Pig chronic wasting disease, including porcine reproductive and respiratory syndrome (PRRS) and postweaning multisystemic wasting syndrome (PMWS), have made a continuous economic damage in pig farms. Airborne spread of livestock viruses are an important spread factor which is difficult to analyze due to invisible airflow and limitation of measurement. The objective of this study is to analyze airborne disease spread between buildings in the experimental pig farm by means of field experiment and computational fluid dynamics (CFD). The field experiments were conducted to capture airborne virus using air sampler and teflon filter along multi points in the experimental pig farm. The samples were tested in terms of virus detection resulting in positive reaction for PRRS and PCV-2 viruses, which can be a firm evidence of airborne virus spread. The CFD simulation model was developed by considering complex topography, wind conditions, building arrangement, and ventilation systems and was used to analyze airborne virus spread according to different wind conditions. The CFD computed result showed a possibility of airborne virus spread via livestock aerosol from infected pig house to neighboring pig houses according to wind directions. The CFD simulation technique is expected to provide significant data for estimating and making a counterplan against airborne disease spread.

쐐기형 요철이 설치된 사각덕트에서의 열/물질전달 및 압력강하 특성 (Heat/Mass Transfer and Pressure Drop in A Square Duct with V-Shaped Ribs)

  • 최청;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1542-1551
    • /
    • 2002
  • The present study investigates the convective heat/mass transfer characteristics and pressure drop inside the rib-roughened cooling passage of gas turbine blades. The internal cooling passage is simulated using a square duct with h- and V-shaped rectangular ribs which have a 60。attack angle. A naphthalene sublimation technique is employed to determine the detailed local heat/mass transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wail. The secondary flow patterns and the local heat transfer in the duct are changed significantly according to the rib orientation. A square duct with ∧ - and V-shaped ribs have two pairs of secondary flow due to the rib arrangement. Therefore, the average heat/mass transfer coefficients and pressure drop of ∧ - and V-shaped ribs are higher than those of the continuous ribs with 90$^{\circ}$ and 60$^{\circ}$attack angles. The ∧-shaped ribs have higher heat/mass transfer coefficients than the V-shaped ribs, and the uniformity of heat/mass transfer coefficient are increased with the discrete ribs due to the flow leakage and acceleration near the surface.

쐐기형 요철이 설치된 사각덕트에서의 열전달 및 압력강하 특성 (Heat/Mass Transfer and Pressure Drop of Square Duct with V-shape Ribs)

  • 최청;이동호;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.280-287
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside the rib-roughened cooling passage of the gas turbine blades. A square duct with rectangular ribs is used and $\wedge-$ and V-shape ribs with $60^{\circ}$ attack angle are installed on the test plate surfaces. Naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wall and the vortices near the side-wall. The local heat transfer and the secondary flow in the duct are changed largely according to the rib orientation. A square duct with $\wedge$ and V-shape ribs has two pairs of secondary flow because of the rib arrangement. So, the duct has complex heat/mass transfer distribution. The average heat/mass transfer coefficient and pressure drop of $\wedge-$ and V-shape ribs are higher than those with $90^{\circ}$ and $60^{\circ}$ attack angles. The average heat/mass transfer coefficient on the $\wedge-shape$ ribs is higher than that on the V-shape ribs. Also, the uniformity of heat/mass transfer coefficient on discrete ribs is higher than that on continuous rib.

  • PDF

한국전통 주거건축에 나타난 환경조절방식에 관한 연구 - 중정형을 중심으로 - (A Study on the Environmental control methods Expression in Korean Traditional Residence - Focusing on the courtyard-type -)

  • 이선민;허범팔
    • 한국실내디자인학회논문집
    • /
    • 제19권3호
    • /
    • pp.128-135
    • /
    • 2010
  • In this paper, traditional residential architecture in South Korea appear to approach environmental regulation as part of ecological architecture of regional climate controlled environment, according to the characteristics and spatial arrangement, and material to the environment was described as a controlled manner. The scope of this study was not large scale housing construction from traditional chusagotaek, yunjeunggotaek, yangjindang, dokrakdang target was the case. Focusing on examples extracted from Korea first eco-friendly characteristics of traditional residential architecture is an extension of nature to explore space and yard space, and South Korea by way of environmental control that appears in traditional architecture, waterproof, moisture, solar radiation, sunlight, ventilation and air Attributes such as environmental regulation and environmental regulation of space, place and manner of materials were described. Korea's research through more traditional residential architecture of the environmental control and a wide range of environmentally friendly eco-construction was that appeared natural to use energy efficiently, it had been available. Later appeared on the Korea traditional architecture through research on environmental control of environmentally friendly ways to navigate and take advantage of the elements, through continuous research and eco-friendly construction to realize the traditional South Korea could provide a prototype of the modern, I thought I'd had.

진공유리 접합을 위한 수소-산소 혼합가스 토치 개발 (Development of hydrogen-oxygen mixed gas torch for joining of vacuum glazing)

  • 황순호;이영림;전의식
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3074-3079
    • /
    • 2009
  • 지속적인 경제 발전과 인구증가로 인하여 에너지 소비가 급증하게 되면서 에너지의 효율적인 사용이 필요하다. 특히 에너지 손실이 많은 건물의 창호에 단열성능이 좋은 고효율 진공유리 사용이 절실한데 아직 가격 및 성능등의 문제로 보급화가 이루어지지 않고 있다. 따라서, 본 연구에서는 저가의 진공유리 개발을 위한 유리 용접용 토치를 설계 및 제작하였다. 연료는 고밀도 열원인 수소-산소 혼합가스를 사용하였고 주로 토치 형상, 노즐 직경, 노즐 배치 등의 최적화를 수행하였다. 끝으로 개발된 토치를 이용하여 두 장의 유리용접을 성공적으로 수행함으로써 저가의 진공유리 개발 가능성을 확인하였다.

매선료법(埋線療法)에 대한 문헌적(文獻的) 고찰(考察) (A Literary Study on Embedding Therapy)

  • 이광호;이동희;권기록;박희수;박영엽
    • 대한약침학회지
    • /
    • 제6권3호
    • /
    • pp.15-21
    • /
    • 2003
  • Background : This study focuses on the new acupuncture method of embedding method which inserts a substance on the acupuncture points for continuous stimulation. Clinical applications and cautions were examined through literary investigations. Results : Based on the literary consideration of embedding method, the following results were obtained : 1. Embedding method is a combination of traditional and embedding technique to provide longer duration of stimulation on the acupuncture points. 2. To administer the embedding method, one needs to utilize a embedding thread besides acupuncture apparatus. Sheep gut is commonly used in China and the surgical thread is the choice in Korea. 3. Embedding method may vary from the patient to patient, depending on the nature and location of the illness. Piercing, embedding, and tying are some of the possibilities. 4. Embedding method may have different arrangement of threads based on the choice of usage. 5. Embedding method is effective for various chronic illnesses such as aches, functional diseases, and the diseases of internal organs. 6. When using the embedding methods, cautions against infection and side effects due to strong stimulation are mandatory.

The practice of blind bolting connections to structural hollow sections: A review

  • Barnett, T.C.;Tizani, W.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.1-16
    • /
    • 2001
  • Due to aesthetic, economic, and structural performance, the use of structural hollow sections as columns in both continuous moment resisting and nominally pinned construction is attractive. Connecting the beams to these sections is somewhat problematic as there is no access to the interior of the section to allow for the tightening of a standard bolt. Therefore, bolts that may be tightened from one side, i.e., blind bolts, have been developed to facilitate the use of site bolting for this arrangement. This paper critically reviews available information concerning blind bolting technology, especially the performance of fasteners in shear, tension, and moment resisting connections. Also provided is an explanation of the way in which the results have been incorporated into design guidance covering the particular case of nominally pinned connections. For moment resisting connections, it is concluded that whilst the principle has been adequately demonstrated, sufficient data are currently not available to permit the provision of authoritative design guidance. In addition, inherent flexibilities in the connections mean that performance equivalent to full strength and rigid is unlikely to be achievable: a semicontinuous approach to frame design will therefore be necessary.

Seismic performance of prefabricated bridge columns with combination of continuous mild reinforcements and partially unbonded tendons

  • Koem, Chandara;Shim, Chang-Su;Park, Sung-Jun
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.541-557
    • /
    • 2016
  • Prefabricated bridge substructures provide new possibility for designers in terms of efficiency of creativity, fast construction, geometry control and cost. Even though prefabricated bridge columns are widely adopted as a substructure system in the bridge construction project recently, lack of deeper understanding of the seismic behavior of prefabricated bridge substructures cause much concern on their performance in high seismic zones. In this paper, experimental research works are presented to verify enhanced design concepts of prefabricated bridge piers. Integration of precast segments was done with continuity of axial prestressing tendons and mild reinforcing bars throughout the construction joints. Cyclic tests were conducted to investigate the effects of the design parameters on seismic performance. An analytical method for moment-curvature analysis of prefabricated bridge columns is conducted in this study. The method is validated through comparison with experimental results and the fiber model analysis. A parametric study is conducted to observe the seismic behavior of prefabricated bridge columns using the analytical study based on strain compatibility method. The effects of continuity of axial steel and tendon, and initial prestressing level on the load-displacement response characteristics, i.e., the strain of axial mild steels and posttensioned tendon at fracture and concrete crushing strain at the extreme compression fiber are investigated. The analytical study shows the layout of axial mild steels and posttensioned tendons in this experiment is the optimized arrangement for seismic performance.