• 제목/요약/키워드: Continous

Search Result 196, Processing Time 0.029 seconds

A Study on the Hemisphere-Type Compression Molding for Continous Fiber-Reinforced Polymeric Composites (연속섬유강화 플라스틱 복합재료의 반구형 압축성형성에 관한 연구)

  • 임용진;오영준;김이곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.149-153
    • /
    • 1999
  • During a hemisphere-type compression molding, the wrinkles are caused by complex stress condition. It is very important to clarify the degree of wrinkles in order to have good products. In this paper, the effects of numbers of needling and initial area on the degree of wrinkles are studied. the degree of wrinkle is expressed as nonhomogeneity.

  • PDF

Continous rail absorber design using decay rate calculation in FEM

  • Molatefi, Habibollah;Izadbakhsh, Soroush
    • Structural Engineering and Mechanics
    • /
    • v.48 no.4
    • /
    • pp.455-466
    • /
    • 2013
  • In recent years, many countries have added railway noise to the issues covered by noise regulations. It is known that the rail is the dominant source of rolling noise at frequency range of 500Hz-2000Hz for the conventional speeds (<160km/h). One of the effective ways to reduce noise from railway track is using a rail vibration absorber. To study the acoustic performance of rail absorber, the decay rates of vibration have long been used by researcher. In this paper, A FE model of a periodic supported rail with infinite element in ABAQUS is developed to study the acoustic performance of the rail absorber. To compute the decay rates, acceleration responses along the rail transferred to MATLAB to obtain response levels in frequency domain and then by processing the response levels, the decay rates obtained for each1/3octav band. Continous rail absorber is represented by a steel layer and an elastomer layer. The decay rates for conventional rail and rail with one-side absorber and also, the rail with two side absorber are obtained and compared. Then, to improve the system of rail absorber, a steel plate with elastomer layer is added to bottom of the rail foot. The vertical decay rate results show that the decay rate of rail vibration along the track is significantly increased around the tuned frequency of the absorber and thus the rail vibration energy is substantially reduced in the corresponding frequency region and also effective in rail noise reduction.

Study on Sampling Techniques for Digital Elevation Model (수치표고모형에 있어서 표고추출법의 연구)

  • Kang, In-Joon;Jung, Jae-Hyung;Kwak, Jae-Ha
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.49-55
    • /
    • 1992
  • Sampling techniques is very important in digital elevation model. There are scanning and digitizing method of sampling techniques. This study is limited in digitizing method. Continous sampling method use contour lines as same entity and grid method is a direct reading of sample elevation in each grid. Triangulated irregular method is needed to identity topographical lines to sample elevation data. As a results, authors know that continous sampling method has economic in input system and triangulated irregular method has a small memory size.

  • PDF

A STUDY ON THE INITIAL TISSUE CHANGES TO INTERMITTENNT FORCE IN DOGS (성견에서 전자력을 이용한 간헐적 교정력에 의한 치아이동시 초기 조직학적 변화에 관한 연구)

  • Sohn, Hong-Bum;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.319-331
    • /
    • 1990
  • The purpose of this study was to help examining force system, optimal treatment, and prevention of relapse. Orthodontic force was generated by electromagnets, therefore duration could be freely controlled, and applied for 4 days in dogs. Force magnitude was 200gm and 50gm. duration was contious and intermittent. Intermittent duration was divided into 2 kinds of types in on/off, 1 mininute/1 minute, 10 seconds/1 minute. The results were as follows: 1. In the intermittent group to which force was applied for 10 seconds and ceased for 1 minute, osteoclast was not observed. 2. In the intermittent group to which 200gm of force was applied for 1 minute and ceased for 1 minute, there was blood circulation in periodontal space on pressure side, but mild hyalinized zone was observed. 3. More number of total osteoclast was counted in the pressure side of continous group to which 200gm of force was applied than in any other groups. 4. More number of frontal osteoclast was counted in the pressure side of intermittent group to which 200gm was applied for 1 minute and ceased for 1 minute than in any other groups. 5. On tension side, less periodontal space widening, more new bone and secondary cementum formation were observed in the intermittent group to which force was applied for 1 minute and ceased for 1 minute than in the continous group.

  • PDF

On the Optimal time for Renewal of Facilities (설비교체의 최적시기 결정에 관하여)

  • Choi, Eun-Chae
    • Journal of the military operations research society of Korea
    • /
    • v.3 no.1
    • /
    • pp.109-114
    • /
    • 1977
  • There are some factors which cause the profits from the production to be decreased or increased. They are, for example, the rise in efficiency of production facilities resulting from the development of the scientific technique, the changes of purchase price of those, and the drop in efficiency of those owing to there long-term operation. In this connection, an manager can get the highest profit by deciding the proper time of new facilities replacement for those in operation or in being planned, which leads to good management planning of his manufactaring business for a given period or a long time. Main purpose of this is the study of how we decide the optimal time or facilities replacement in order to maximize the total profits for a given period by considering them as continous function as to the time in the case where a machineng is set. The results are following: 1. The definition of profit function is in duced in consideration of the breakdowns caused from continous operation of the machinery. 2. The necessary conditions are obtained for the optimal time of replacement and find out the methods of its solution. 3. Comparing between the 'Short cut' method and method in this paper, we obtained that our method is more realistic.

  • PDF