• Title/Summary/Keyword: Contamination source

Search Result 518, Processing Time 0.03 seconds

Phoswich Detector for Simultaneous Measuring Alpha/beta Particles (알파/베타선 동시측정용 phoswich 검출기)

  • Kim, Gye-Hong;Park, Chan-Hee;Lee, Kune-Woo;Jung, Chong-Hun;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  • PDF

ISO14001-based u-LCA System Development for Operation of Environmental Facilities (환경기초시설 운영을 위한 ISO14001 기반 u-LCA 시스템 개발)

  • Han, Kwang-Rok;Lee, Ki-Cheol;Sohn, Surg-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2117-2125
    • /
    • 2009
  • This paper describes an information system of operation adequacy in environmental facilities such as environmental contamination prevention and processing equipments, which is namely, an integrated management system for environmental facilities. By developing this system, we can improve environmental characteristics and maximize the efficiency throughout the life cycle from generation of contaminant source to contamination prevention processing, and to contaminant disappearance. In order to meet these objects, we have developed ubiquitous life cycle assessment(u-LCA) for environmental facilities, which is an ISO14001-based incineration facility information system. The developed system is currently operating for test at an incinerator in Koyang city. Due to this system, the managers can confirm the operation condition of the incinerator with real-time and they will be able to improve the problems immediately.

Antimicrobial Resistance Characteristics of Gram-Negative Bacteria Isolated from Inland Pollution Sources in the Drainage Basin of Iwon-myeon (Taean-gun), South Korea (태안군 이원면 육상오염원 배출수에서 분리한 그람음성균의 항생제 내성 특성)

  • Park, Bo Mi;Kim, Min Ju;Jeong, Yeon Gyeom;Park, Jin Il;Yu, Hong Sik;Oh, Eun Gyoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.4
    • /
    • pp.377-387
    • /
    • 2021
  • Fecal contamination levels of discharge water from inland pollution sources were investigated in Iwon-myeon (Taean-gun), South Korea. Gram-negative bacteria were isolated during the investigation and the antimicrobial resistance patterns of the isolates were examined to estimate their impact on the coastal environment. The ranges of total coliform and fecal coliform of 12 samples from four major inland pollution sources were 79-490,000 MPN/100 mL and 2.0-490,000 MPN/100 mL, respectively, with the highest level of fecal contamination at Station No. 3. A total of 137 strains (14 genus) were isolated, of which 86 strains (62.8%) were Enterobacteriaceae. The identified isolates were as follows: Pseudomonas spp. (35 strains), Klebsiella spp. (20 strains), Serratia spp. (20 strains), and Escherichia spp. (19 strains). The isolated Gram-negative bacteria showed the highest antimicrobial resistance to ampicillin (81.8%), followed by amoxicillin/clavulanic acid (64.2%), ceftiofur (61.3%), and cefoxitin (59.1%). Antimicrobials in which less than 10% of isolates showed antimicrobial resistance were ciprofloxacin (3.6%) and gentamicin (2.2%). Resistance to one or more antimicrobials was observed in 121 strains (88.3%) and 84 strains (61.3%) showed a tendency for multiple antimicrobial resistance.

Construction of a Preliminary Conceptual Site Model Based on a Site Investigation Report for Area of Concerns about Groundwater Contamination (지하수 오염우려지역 실태조사 보고서 기반의 사전 부지개념모델 구축)

  • Kim, Juhee;Bae, Min Seo;Kwon, Man Jae;Jo, Ho Young;Lee, Soonjae
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.spc
    • /
    • pp.64-74
    • /
    • 2022
  • The conceptual site model (CSM) is used as a key tool to support decision making in risk based management of contaminated sites. In this work, CSM was applied in Jeonju Industrial Complex where site investigation for groundwater contamination was conducted. Site background information including facility types, physical conditions, contaminants spill history, receptor exposure, and ecological information were collected and cross-checked with tabulated checklist necessary for CSM application. The CSM for contaminants migration utilized DNAPL transport model and narrative CSMs were constructed for source to receptor pathway, ecological exposure route, and contaminants fate and transport in the form of a diagram or flowchart. The component and uncertainty of preliminary CSM were reviewed using the data gap analysis while taking into account the purpose of the survey and the site management stage at the time of the survey. Through this approach, the potential utility of CSM was demonstrated in the site management process, such as assessing site conditions and planning follow-up survey work.

Identification of Jet fuel (JP-8) in Petroleum Hydrocarbon Contaminated Soil through the Qualitative Analysis of Antioxidants (유류 오염 토양 중 산화방지제 정성 분석을 통한 항공유(JP-8) 유종 판별)

  • Kim, Yonghun;Lee, Goontaek;Jang, Hanjeon;Jo, Yunju;Kim, Moongun;Choi, Jaeho;Kang, Jiyoung
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.4
    • /
    • pp.37-48
    • /
    • 2022
  • Accurate analysis of petroleum hydrocarbons in soil is an important prerequisite for proper source tracking of contamination. Identification of petroleum compounds is commonly carried out by peak pattern matching in gas chromatography. However, this method has several technical limitations, especially when the soils underwent biological, physical and chemical transformation. For instance, it is very difficult to distinguish jet fuel (JP-8) from kerosene because JP-8 is derivatized from secondary reaction between chemical agents (e.g. anti-oxidants, antifreezer and so on) and kerosene. In this study, an alternative method to separately analyze JP-8 and kerosene in the petroleum hydrocarbon contaminated soil was proposed. Qualitative analyses were performed for representative phenolic antioxidants [2,6-di-tert-butyl phenol (2,6-DTBP), 2,4-di-tert- butylphenol(2,4-DTBP), 2,6-di-tert-butyl-4-methyl phenol (2,6-DTBMP)] using a two dimensional gas chromatograph mass spectrometer (2D GC×GC-TOF-MS). This qualitative analysis of antioxidants in soil would be a useful complementary tool for the peak pattern matching method to identify JP-8 contamination in soil.

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

Assessment of Groundwater Contamination Using Geographic Information System (지리정보시스템을 이용한 지하수 오염 평가)

  • 전효택;안홍일
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.3
    • /
    • pp.129-140
    • /
    • 1998
  • In this study two sites were selected to investigate groundwater contamination and spatial relationship between pollution level and its source. One is the Asan area, agricultural district where pollution sources are scattered. The other is the Gurogu area of Seoul city, industrial district where industrial complex and residential areas are located. Groundwater samples collected from these districts were analysis for chemical constituents. The attribute value files of the chemical constituents of groundwater and the spatial layers have been constructed and the pollution properties have been investigated to find out spatial relationships between the groundwater constituents and pollution sources using CIS. Relatively high contents of Si and HCO$_3$ in groundwater from the Asan area reflect the effect of water-rock interaction, whereas high contents of Cl, NO$_3$, SO$_4$and Ca in groundwater from the Gurogu area are due to the pollution of various sources. Pollution over the critical level of Korean Dinking Water Standard has been investigated from 15 sampling sites out of 40 in the Asan area, and 33 sampling sites out of 51 in the Gurogu area. There is pollution of NO$_3$, Cl, Fe, Mn, SO$_4$and Zn in groundwater from the Gurogu area, and that of NO$_3$, SO$_4$and Zn in groundwater from the Asan area. Principal pollution in both areas is NO$_3$contamination. Deep groundwater from the Asan area is not contaminated with NO$_3$except for one site and most of shallow groundwater near the potential point sources such as factory and stock farm is contaminated seriously. Groundwater from the Gurogu area has been already polluted seriously considering the fact of contamination of deep groundwater. This study reports a spatial relationship between the pollution level and pollution source using GIS.

  • PDF

Estimation of Nitrate-nitrogen Contamination Sources in Cheju Island Groundwater using $\delta$$^{15}$ N Values ($\delta$$^{15}$ N값을 이용한 제주도 지하수중의 질산성질소 오염원추정에 관한 연구)

  • 오윤근;현익현
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.1
    • /
    • pp.1-4
    • /
    • 1997
  • This study was carried out to find out the source of nitrate-nitrogen (NO$_3$-N) contamination in the groundwater in Cheju Island. Among the sites which have exceeded or may exceed the criterion level (10 mg/L) of NO$_3$-N in drinking water, seven sampling sites including two reference sites were chosen. The former regions are mainly agricultural ones (A-1 to A-6) and residential (R). The latter regions are forest (F-1 and F-2). The predicted major source and its contribution to NO$_3$-N concentration at each site, using $\delta$$\^$15/N and NO$_3$-N concentration, were as follow; Those at A-1, R and F-1 was 61.1%, 50.0% and 20.0% to manure or domestic sewage, 27.8%, 45.7% and 40.0% to chemical fertilizers and 11.1%, 4.3% and 40.0% to natural soil, respectively. Those at A-2 to A-6 were 37.8%, 25.0%, 40.9%, 26.2% and 35.7% to manure or domestic sewage, 59.6%, 71.7%, 53.0%, 71.5% and 60.2% to chemical fertilizers and 2.6%, 3.3%, 6.1%, 2.3% and 4.1% to natural soil, respectively.

  • PDF

Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin (금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사)

  • Na, Seungmin;Kwon, Heongak;Kim, Gyeong Hoon;Shin, Dongseok;Im, Tae Hyo
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.363-377
    • /
    • 2016
  • This study was investigated the pollutant load, contamination properties, pollution condition of the fine parts of tributary, the influence of Nakdong river watershed and etc. in the tributaries. The contaminated tributaries were that among the Kumho and Nam river or were too far from site of water quality monitoring stations, regularly. As a result, the water quality level was almost similar between Nam and Kumho River, except for certain parameter including TN(Total Nitrogen), Chl-a(Chlorophyll-a) and SS(Suspended Solid) in which Kumho river were 20~120%. The point discharge load(kg/day) and load density ($kg/day/km^2$) of tributaries were different the pollution level according to the flow-rate ($m^3/sec$) and stream influence area($km^2$), and the difference of these was observed highly at Nam river. Specific contamination investigation of tributaries in Nam and Kumho river watershed was conducted from two to nine points of the fine parts of tributaries depending on the confluence sites and shapes. This result observed high at the Dalseocheon and Uriyeongcheon, respectively. Beside, the pollutant load contribution rate of Nakdong watershed was high about 10% at the Dalseocheon and Uiryeongcheon. This was due to the differences of the environments about the industrial complex, metropolis residence property, agricultural cultivation, livestock pen and the downstream of non-point source.

Environmental Contamination and Bioavailability Assessment of Heavy Metals in the Vicinity of the Dogok Au-Ag-Cu Mine (도곡(Au-Ag-Cu)광산 주변지역의 중금속 원소들의 환경오염특성 및 생체흡수도 평가)

  • Lee Sung-Eun;Lee Jin-soo;Chon Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.135-142
    • /
    • 2005
  • In order to investigate the contamination level and seasonal variation of heavy metals and evaluate the bioavailability of toxic elements, environmental geochemical survey was undertaken at the Dogok Au-Ag-Cu mine area. The main pollution sources in the area were suggested as tailings, mine waste materials and mine water. Elevated levels of $140{\cal}mg/{\cal}kg{\;}As,{\;}107{\cal}mg/{\cal}kg{\;}Cd,{\;} 3017{\cal}mg/{\cal}kg{\;}Cu,{\;}12926{\cal}mg/{\cal}kg{\;}Pb,{\;}9094{\cal}mg/{\cal}kg$ Zn(before rainy season) were found in mine tailings. Concentrations of heavy metals in farmland soils exceeded normal level in nature soil (Bowen, 1979). The highest level of heavy metals was found in water samples near the mine tailing dumps regarded as a main pollution source of toxic elements in the area. These concentrations decreased to downstream due to the effect of dilution. From the results of sequential extraction analyses for tailings and soils, non-residual forms of heavy metals were found, which indicate the contamination to be progressing by continuing weathering and oxidation. Cadmium and Zn would be of the highest mobility in all samples. The bioavailability of Cd, Cu, Zn and As using SBET analysis from paddy soils was $53.3{\%},{\;}46.5{\%},{\;}41.0{\%}$ and $37.0\%$, respectively. The farmland soil sample(S3) showed the highest total concentration and bioavailability of heavy metals.