• 제목/요약/키워드: Contamination sensitivity coefficient

검색결과 7건 처리시간 0.026초

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

자동차 연료펌프의 오염민감도 실험 연구 (An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump)

  • 이재천;장지현;신현명
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

Rapid Quantification of Salmonella in Seafood Using Real-Time PCR Assay

  • Kumar, Rakesh;Surendran, P.K.;Thampuran, Nirmala
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권3호
    • /
    • pp.569-573
    • /
    • 2010
  • A quantitative detection method for Salmonella in seafood was developed using a SYBR Green-based real-time PCR assay. The assay was developed using pure Salmonella DNA at different dilution levels [i.e., 1,000 to 2 genome equivalents (GE)]. The sensitivity of the real-time assay for Salmonella in seeded seafood samples was determined, and the minimum detection level was 20 CFU/g, whereas a detection level of 2 CFU/ml was obtained for pure culture in water with an efficiency of ${\geq}85%$. The real-time assay was evaluated in repeated experiments with seeded seafood samples and the regression coefficient ($R^2$) values were calculated. The performance of the real-time assay was further assessed with naturally contaminated seafood samples, where 4 out of 9 seafood samples tested positive for Salmonella and harbored cells <100 GE/g, which were not detected by direct plating on Salmonella Chromagar media. Thus, the method developed here will be useful for the rapid quantification of Salmonella in seafood, as the assay can be completed within 2-3 h. In addition, with the ability to detect a low number of Salmonella cells in seafood, this proposed method can be used to generate quantitative data on Salmonella in seafood, facilitating the implementation of control measures for Salmonella contamination in seafood at harvest and post-harvest levels.

Determination of Emamectin Benzoate in Eel, Halibut, and Shrimp Using QuEChERS-EDTA and LC-MRM

  • Cho, Ha Ra;Kim, Dong Yoon;Lee, Hyo Chun;Han, Sang Beom;Shin, Ho-Chul;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.100-104
    • /
    • 2018
  • As a part of efforts to establish the positive list system (PLS) in South Korea, a method to determine residual emamectin benzoate (EB) in various aquatic products using QuEChERS-EDTA and LC-MRM was developed. The developed method was validated in the aspects of specificity, linearity (correlation coefficient of at least 0.996), sensitivity (the limit of detection and the lower limit of quantitation ${\leq}5ng/g$), recovery (the recovery range of 87.4 and 96.2), and precision (the relative standard deviation of recovery between 0.9 and 13.5). Additionally, the validated method was successfully applied for monitoring EB contamination in eel, halibut, and shrimp collected from local food markets. To our knowledge, the present method is the first one to determine residual EB in various aquatic products at the level satisfying the PLS and could contribute to the establishment of the PLS in South Korea.

Methodological Study on Measurement of Hydrogen Abundance in Hydrogen Isotopes System by Low Resolution Mass Spectrometry

  • Lia, Jin-Ying;Shib, Lei;Hub, Shi-Lin
    • Mass Spectrometry Letters
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 2011
  • China's rapid economic growth has resulted in significant environmental side effects. Therefore, China has been interested in reducing her dependence on foreign oil and gas by developing technologies needed for hydrogen, in addition to her increasing energy mix of nuclear and renewable energy form, such as solar and wind power. There are three isotopes of hydrogen, i.e. protium (P or H), deuterium (D), and tritium (T). Both deuterium and tritium are important materials in nuclear fuel cycle industry. Tritium is one of the critical radioactive nuclides. Planning for and implementing contamination control as a part of normal operation and maintenance activities is an important function in any hydrogen facility, especially tritium facility. The development of hydrogen isotopes analysis is the key issues in this area. Mass spectrometry (MS) with medium (about 600) and high resolution (> 1,400) is commercially available; however, the routine analysis of hydrogen isotopes is done with low-resolution MS (< 200) in China. This paper summarizes the progress of MS measurement technology for hydrogen isotope abundance in China, focusing on our lab's research program and technical status. An analyzing method has been introduced for accurate measurement of tritium abundance in the H.D.T system by low resolution MAT-253 MS. The quotient of compression ratio coefficient is determined by building up equipment for laboratory-scale preparation of secondary standard gases and by considering the difference in sensitivity between hydrogen isotopes. The results show that the measured value is reproducible within the relative error range of 0.8% for gas samples of different tritium abundance.

실내모형시험과 수치해석을 통한 SVE의 효율성 평가 (Evaluation of Efficiency of SVE from Lab-scale Model Tests and Numerical Analysis)

  • 석희준;서민우;고경석
    • 대한토목학회논문집
    • /
    • 제28권1B호
    • /
    • pp.137-147
    • /
    • 2008
  • SVE 공법은 휘발성 유기물로 오염된 불포화대의 정화 공법으로 널리 적용되어 왔다. 본 연구에서는 SVE 적용시 오염물 제거 기작을 관찰하기 위해 모형조 시험을 수행하였으며, 이로부터 SVE의 주요 특징인 tailing 현상, 즉 후반부로 갈수록 제거 속도가 급격히 느려지는 꼬리 효과를 확인하였다. 본 연구에서는 액상 막에서의 확산 제약 현상을 고려할 수 있는 수치 모델을 적용하였으며, 모형조 시험 결과와 구축된 수치 모델링을 통해 SVE의 전형적인 특징이 꼬리 현상을 적절하게 모사할 수 있었다. 또한 4가지 변수에 대한 민감도 분석을 수행하여, 총토양농도의 백분율은 액상확산계수가 클수록, 가스상 확산계수가 클수록, 실제확산경로가 짧을수록, 물포화도가 작을수록 빠르게 감소함을 확인하였다.