• Title/Summary/Keyword: Contamination Test

Search Result 640, Processing Time 0.026 seconds

GEOTECHNICAL CHARACTERISTICS OF CRUDE OIL-CONTAMINATED GROUND (원유(Crude-Oil)로 오염된 지반의 역학적 특성)

  • 신은철;홍승서;강욱현
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1997.05a
    • /
    • pp.43-46
    • /
    • 1997
  • The results of an investigation conducted to study the effect of crude oil contamination on the geotechnical properties of sand of presented. The effect of the degree of oil contamination on compaction characteristics, shear strength, and one-dimensional compression characteristics has been investigated. The test results indicate that the compaction characteristics are somewhat influenced by oil contamination. The angle of internal friction of sand (based on total stress basis) decreases due to the presence of oil within the pore spaces in sand. The compression characteristics of sand are significantly-influenced by oil contamination. The details of the tests conducted and the results are presented in the paper.

  • PDF

An Experimental Study on the Light Transmission Characteristics with Oil Contamination (윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • Changes in light transmission characteristics caused by various types of oil contaminations were experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon duct, two kinds of solutions and grease were used for the test contaminants in this work. Light intensity of the transmitted light was measured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and poly-meric fibers in terms of the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change in lubricating oils.

The Contamination Characteristics of Insulators with Heights (에자의 설치 높이에 따른 오손 특성)

  • Kang, Yeon-Woog;Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.470-472
    • /
    • 2001
  • This paper explains the characteristic differences in the process of insulator contamination according to heights. To investigate the contamination characteristics, test insulators are suspended to tower at the heights of 8m, 15m, 33m and 50m. That points stand for distances from insulator to bottom of the 22.9 kV, 154 kV, 345 kV and 765 kV towers, respectively. Generally, the contamination level of transmission lines is determined on the basis of measured value at the height of around 10m due to limitation in measuring. As the contamination level could be affected by the heights and the location of the constructed tower, it is suggested that the measured values should be corrected to minimize errors.

  • PDF

A monitoring for the establishment of microbial limit of herbal medicine(I) (한약재의 미생물허용한도 설정을 위한 모니터링(I))

  • Lee, Ju-Hyun;Jeon, Won-Kyung;Go, Byoung-Seob;Chun, Jin-Mi;Lee, A-Yeong;Kim, Ho-Gyoung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.1
    • /
    • pp.49-57
    • /
    • 2006
  • Objectives : This study has attempted to establish an organized system for the microbiological quality of raw materials which are important factors in preparing the standard for microbial limits. Methods : This study has first set up microbial contamination limit test. total aerobic microbial count and total fungi count, int accordance with testing method of the Korea Pharmacopeia 8th edition in order to establish an inspection standard for microbial contamination. Results : The microbial contamination of 18 items that are highly prone to contamination by three regions(Seoul, Daejeon, Gyeongsangbuk-do), As a result, Morus alba Linne and Rehmannia glutimosa Liboschitz var. purpurea Makino showed as high contaminated by WHO's Microbial Contamination Limit standard. In case of Yukjin medicine in the Theory of Herb Medicinal Properties, total bacterial contamination rate showed as 17.7%, total fungal contamination rate showed as 41.2% and total aerobic mircobial count and total fungi count on Ephedra sinica Stapf. Pinellia ternate Breitenbach, Evodia officinalis Dode showed as high measured. The microbial conatmination rate materials which make up Yukmijihwanghwan were mostly high therefore the total aerobic microbial count was measured as high in case of Yukmijihwanghwan, the characteristics about microbial contamination strain is to be researched. Conclusions : By combining the basic data and experimental results related to microbial contamination of herb medicine, the most ideal storage standards for herb medicine has been attempted to be presented.

  • PDF

A Survey on Microbial Contamination of Currently-Sold Drugs (I) -Bacterial contamination of marketed liquid- (시장의약품(市販醫藥品)의 미생물(微生物) 오염도(汚染度) 조사(調査) (제1보)(第1報) -시판내복액제(市販內服液劑)의 세균오염도(細菌汚染度)-)

  • Park, Young-Ju;Kim, Young-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.3 no.4
    • /
    • pp.5-15
    • /
    • 1973
  • An investigation was carried out on a basis of the bacteriological examination with a view to detecting the degree of bacterial contamination for the 77 samples collected from the locally-sold liquid specialties. It's test period was 50 days from July 10 to August 30, 1971. Specially, the survey has put emphasis on the population of general bacteria and the identification of coli-form group, staphylococcus species, streptococcus species, bacillus species, fungi, and yeast species from liquid samples. The results obtained are summarized as follows; (1) For the 77 samples tested, the contamination of general bacteria was found out as minimun 0, i,e., maximum, $12{\times}10^4$ and the total average $45{\times}10^2$ per milliliter. (2) Although streptococcus species could not be detected with the samples, the contamination of the coli-form and staphylococcus species means the strong suggestion of the possibility of pathogenic bacterial contamination. (3) Specially, the products which stay in the neutral pH range and use suspending agents need to care for the microbial contamination in the manufacturing crocess. (4) It is thought necessary to perform the microbiological quality control in the liquid preparations only at least. (5) As the microbial contamination degree in the liquid decreases according to the elapse of time, the microbiological quality control will have to be carried out immediately after the completion of the manufacturing process in order to know the accurate degree. (6) The author thinks that the main reason of the microbial contamination in the liquid is the contamination during the manufacturing process. (7) For the purpose of prevention of the microbial contamination in liquid, therefore, it is more important to make efforts for the rationalization of manufacturing process, the improvement of equipment and environment, the specific training of workers for hygienic knowledges, etc. rather than the use of preservatives for the preparations.

  • PDF

Experimental Evaluation on Occurrence Possibility of Pollutants from Aggregates (순환골재의 오염물질 발생 가능성에 관한 실험적 평가)

  • Park, Jeong-Ho;Seong, Jin-Uk;Park, Je-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • This study was on leaching test(KSLT, TCLP) of the aggregate for the products(RA-1) and for the site(RA-2) to evaluate the characteristics of contaminants and the possibility of contamination arising from the aggregate. On the basis pH, conductivity and heavy metal contents in the aggregate, RA-1 indicated higher than RA-2. As a result of the leaching test, the pollutants were eluted from the aggregate increased as the particle size of the aggregate was smaller. The pH in the aggregate had a strong alkali by a pH value of 9.0~12.3, the conductivity was higher in less than 10mm RA-1 due to the leaching of dissolved inorganic ions. The heavy metals satisfied the leaching standards of KSLT and less 10% was eluted from the aggregate. As a result of evaluating water pollution possibility of the aggregate, the pH displayed in items with a very high possibility of contamination, conductivity and turbidity did in item with a low possibility of contamination and on the other hand the heavy metals did in item with a very low possibility of contamination.

Detection of Tobamoviruses and Survey on Contamination Rate in Commercial Pepper Seeds Using Gelatin Particle Agglutination Test (젤라틴입자응집반응법을 이용한 국내 시판 고추종자의 Tobamovirus 검출 및 오염률 조사)

  • 한정헌;장태호;이철호;김영호;나용준
    • Research in Plant Disease
    • /
    • v.7 no.3
    • /
    • pp.170-174
    • /
    • 2001
  • Gelatin particle agglutination test (GPAT) was optimized for detection of Tobamovirus and contamination of the virus in commercial pepper seeds was evaluated. The optimum concentration of ${\gamma}$-globulin G, specific to tobacco mosaic virus pepper strain, was 100 ug/ml. The sensitivity of GPAT for the detection of Tobamovirus in pepper seeds was as high as enzyme-linked immunosorbent and dot immunoblotting assays. Optimum dilution ranges of the seed extract for GPAT was 5-25 folds. Using the optimized GPAT with above conditions, the rate of Tobamovirus contamination in seeds was turned out to be average of 79.1%.

  • PDF

A Study on the Effect of Soil Wineral and Component of the Pore Fluid to the Electrical Resistivity (흙의 구성광물과 간극수의 성분이 비저항값에 미치는 영향에 관한 연구)

  • Yoon, Chun-Kyeong;Yu, Chan;Yoon, Kil-Lim
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.59-64
    • /
    • 1998
  • The environmental problem of the rural area has been accelerated in soil as well as water. Soil contamination is usually caused by improper operation of landfills, abandoned mine fields, accidental spills, and illegal dumpings. Once soil contamination is initiated, pollutants migrate and may cause groundwater contamination which takes much effort for remediation. Early detection, therefore, is important to prevent further contamination. Electrical resistivity method was used to detect soil contamination, but it was not effective to the heterogeneous condition. Static cone penetrometer test (CPT) has been used widely to investigate geotechnical properties of the underground. In this study, electrical resistivity method and CPT are combined to improve the applicability of it. The pilot test was performed to examine the variation of electrical resistivity with different soil minerals and pore fluid characteristics. Soil samples used were poorly graded sand, silty sandy soil, and weathered granite soil. For all the cases, electrical resistivity decreased with increasing of moisture content. Soil mineral also affected the electrical resistivity significantly. Above all, leachate addition in the pore fluid was very sensitive and caused decreasing of electrical resistivity markedly. It implies that electrical resistivity method can be applied to investigate pollutant plume effectively. This is specially sure when the sensors contact the contaminated soils directly. The CPT method involves cone penetration to the ground, therefore, underground contamination around the cone could be investigated effectively even for heterogeneous condition as it penetrates if electrical resistivity sensors are attached on the cone.

  • PDF

Technical Approaches for Assessment of Ground Water Contamination with TCE in an Industrial Area

  • Jeon, Kweonho;Yu, Soonyoung;Jeong, Jangsik;Son, Yanglae
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.10a
    • /
    • pp.70-86
    • /
    • 2003
  • Despite its usability, TCE has been managed as a hazardous material due to the toxicity and many contamination cases were surveyed in some developed countries. U.S.EPA(Kram et al., 2001) suggested DNAPL characterization methods and approaches based on survey experiences at several sites. However, Korea has not the least assessment of contamination and trial of remediation, although there are a lot of doubtable areas where ground water would be contaminated with TCE. In this study, we try to assess the volume and extent of ground water contamination with TCE and delineate the contamination source zones in an industrial area. Ground water in this area flows through fractures and the contaminant TCE has the properties of high volatility, high density and low partitioning to soil material. Thus, we applied a variety of technical approaches to identify the contamination status; documentary, hydrogeochemical, hydrogeological and geological surveys. In addition, additional survey was performed based on the interim findings, which showed that ground water contamination was limited to the relatively small area with high concentrations to the deep place. The contamination source zone is estimated to be the asphalt test institute where a great deal of TCE has been used to analyze the amount of asphalt soluble in TCE since 1984. Based on the contamination characterization and a myriad of documents about ground water remediation, appropriate site remediation management options will be recommended later. This study is now under way and this paper was focused on describing the technical approaches used to achieve the goals of this study.

  • PDF

Chromatic Parameters in the Condition Monitoring of Synthetic Hydraulic Oils

  • Ossia, C.V.;Kong, H.;Han, H.G.;Markova, L.;Makarenko, V.
    • KSTLE International Journal
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • Chromatic device was developed using light emitting diodes, optic fibers and photodiodes. Chromatic ratio and total contamination parameters based on transmitted light intensity in Red, Green, and Blue wavelengths were used for oil chemical and particulate contamination assessment. Chromatic ratio criterion was found independent of the particulate contamination of oil; but depended on chemical degradation, being more sensitive for synthetic than mineral hydraulic oil. Total contamination index of the sensor depended on both the chemical degradation and particulate contamination of the oil; being most sensitive in blue wavelength, and least in the red. Test results for synthetic hydraulic oils monitored corroborated with results of other tests such as viscosity, total acid number, elemental optical emission spectroscopy, particulate counts and UV-VIS photospectrometry. Chromatic ratio showed a clearer indication of oil degradation, compared to key monitoring parameters such as total acid number, viscosity and particle counts. The results showed that these parameters are effective criteria for the condition monitoring of synthetic hydraulic oils.