• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.038 seconds

Distribution of Metallic Elements Contamination in River Deposits and Farmland in the Vicinity of an Abandoned Korean Mine (폐광산 인근 농경지 및 하천 퇴적토의 중금속 오염 특성)

  • Lee, Hwan;Lee, Yoonjin
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.133-145
    • /
    • 2020
  • Soil in mine waste-rock fields, and at the pithead, sediments and farmlands around an abandoned mine in the Chungcheong Province of South Korea were investigated to assess the distribution of metallic elements and to understand the scope of the pollution. Reddening was observed from the mine up to a distance of 61 m. Losses of waste rock around the mine were assessed over a section of 1800 ㎥. Yellowish precipitates on the bottom of a stream were identified as ferrihydrite and goethite. For anions, a mean sulfate ion level over 773.6 mg/L was found during August in the river water samples. Mine drainage at the site was shown to have a pH of 4.9 and a sulfate concentration of 1557.8 mg/L during the August rainy season. A possible cause of the metallic element contamination in the mine is waste-rock loss, because mine waste-rock is located on the slope in this area. In conclusion, the total soil area to be treated, based on the amount that exceeded the recommended Korean soil pollution levels, was assessed to be 10,297 ㎡.

Heavy Metal Contamination in Surface Water Used for Irrigation: Functional Assessment of the Turag River in Bangladesh

  • Arefin, M. Taufique;Rahman, M. Mokhlesur;Wahid-U-Zzaman, M.;Kim, Jang-Eok
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.1
    • /
    • pp.83-90
    • /
    • 2016
  • The aim of the present study was to evaluate the degree of metal contamination of the Turag River water and its suitability for irrigation. Twenty water samples were analyzed for physicochemical parameters and metals viz., calcium, magnesium, potassium (K), sodium, copper (Cu), zinc (Zn), iron (Fe), manganese (Mn), lead (Pb), cadmium (Cd), chromium (Cr), and nickel (Ni). All water samples were slightly alkaline to alkaline. Regarding electrical conductivity (EC), all samples were suitable for crop in soils with moderate permeability and leaching. Water samples were medium salinity and low alkalinity hazard classes. In terms of total dissolved solids (TDS), all samples were classified as freshwater. As per sodium adsorption ratio (SAR) and soluble sodium percentage (SSP), all samples were classified as excellent. No residual sodium carbonate (RSC) was detected in any of the samples, indicating suitability for irrigation; and all samples were considered very hard. Cr and Mn contents in all samples were above FAO guideline values and, therefore, these metals were considered toxic. Zn, Cu, Pb, Cd, and Ni concentrations were below acceptable limit for irrigation and do not pose a threat to soil environment. Significant relationships were found between EC and TDS, SAR and SSP, SAR and RSC, and SSP and RSC. The combinations of ions such as K-Zn, K-Fe, K-Cu, K-Mn, K-Pb, Zn-Fe, Zn-Cu, Zn-Mn, Fe-Mn, Cu-Mn, Cu-Pb and Mn-Pb exhibited significant correlation. This study revealed that Turag River water samples are contaminated with Cr and Mn. This fact should not be ignored because water contamination by metals may pose a threat to human health through food chain.

Risk of DNA contamination through fingerprint brush, during the dusting of living persons and deceased (살아있는 사람과 사망한 사람의 지문을 채취하는 과정에서 지문 브러쉬의 DNA 오염 정도 연구)

  • Min, Hee Won;Hong, Sungwook
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.85-93
    • /
    • 2016
  • This study investigated the possibility of DNA contamination during fingerprint collection when using a fingerprint brush. Two kinds of brushes were selected: powdered brushes and neat (not powdered) brushes. The fingerprints were collected from the tips of all the fingers and near the wrists of both living and deceased persons using the two brushes. Both brushes were analyzed for the DNA contents and profiles. The results obtained confirmed the transfer of DNA onto both brushes, although the results showed that the powdered brushes carried more DNA compared with the neat brushes. More DNA was transferred onto the brushes used on deceased persons than onto the brushes used for living persons. Only partial DNA profiles were obtained from the brushes, which is due to the presence of other sources of DNA on the surfaces of the skin of both living and deceased persons. This phenomenon confirmed the DNA contamination during fingerprint collection when fingerprint brushes were used.

Distribution of heavy metals in soils around the Keum-Jung mine and remediation (금정광산 주변 토양의 중금속 오염현황 및 그 처리 방안)

  • 이기철;이승길;한인호;최광호;정덕영
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.25-34
    • /
    • 1999
  • This geochemical study was carried out to find out the distribution of metals and cyanide in the soils around the Keum-Jung abandoned mine. Chemical analysis showed that extractable As contents in the soils near the mine exceeded 15mg/kg, Korean standard of soil contamination for farm land. The Results suggests that As contamination is due to input of tailings in the soils. According to total decomposition of tailings, As was highly concentrated in tailings. The water in a tailings impoundment was changed to acidic and contaminated by metals and sulfate which were released through oxidation of impoundment. Acid mine drainage from the tailings impoundment distribution channels directed to the paddy soils. The proper measures are required to prevent contamination of the soil and water in the vicinity of the Keum-Jung mine.

  • PDF

Assessment of Groundwater Contamination Vulnerability in Miryang City, Korea using Advanced DRASTIC and fuzzy Techniques on the GIS Platform (개선된 DRASTIC 기법과 퍼지기법을 이용한 밀양지역 지하수오염 취약성 평가)

  • Chung, Sang Yong;Elzain, Hussam Eldin;Senapathi, Venkatramanan;Park, Kye-Hun;Kwon, Hae-Woo;Yoo, In Kol;Oh, Hae Rim
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.4
    • /
    • pp.26-41
    • /
    • 2018
  • The purpose of this study is to improve the Original DRASTIC Model (ODM) for the assessment of groundwater contamination vulnerability on the GIS platform. Miryang City of urban and rural features was selected for the study area to accomplish the research purpose. Advanced DRASTIC Model (ADM) was developed adding two more DRASTIC factors of lineament density and landuse to ODM. The fuzzy logic was also applied to ODM and ADM to improve their ability in evaluating the groundwater contamination vulnerability. Although the vulnerability map of ADM was a little simpler than that of ODM, it increased the area of the low vulnerability sector. The groundwater vulnerability maps of ODM and ADM using DRASTIC Indices represented the more detailed descriptions than those from the overlap of thematic maps, and their qualities were improved by the application of fuzzy technique. The vulnerability maps of ODM, ADM and FDM was evaluated by NO3-N concentrations in the study area. It was proved that ADM including lineament density and landuse factors produced a more reliable groundwater vulnerability map, and fuzzy ADM (FDM) made the best detailed groundwater vulnerability map with the significant statistical results.

Electrical Surveys at the Seokdae Waste Landfill of Pusan (부산 석대 폐기물 매립지에서의 전기탐사)

  • Kiehwa Lee;Jong-Ryeol Yoon
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.4
    • /
    • pp.185-190
    • /
    • 1997
  • Electrical surveys were conducted at the Seokdae waste landfill in July,1996. Within the landfill, 4 lines of dipole-dipole surveys and 7 Schlumberger soundings were carried out and 2 soundings in front of the landfill. In the landfill, interpretations of the survey data show low resistivity zones below 10 Ωm to a depth of 50 m from the surface and such low resistivity zones of the D block are thicker than those of the other blocks by about 2~10 m. Considering the depth of the bedrock and the height of waste reclamation, no evidence of bedrock contamination by leachate is indicated. But it is inferred that the weathered zones are contaminated in the landfill. In the block A and B, minor fault having the strike of N$70^{\circ}$W have been confirmed by dipole-dipole surveys, so future contamination of the bedrock by leachate is possible The degree of ground contamination is the highest in the D block due to the leachate plume mainly heading for this block. On the other hand, electrical soundings do not indicate ground contamination by leachate in the front area of the landfill.

  • PDF

A Study on Groundwater Contamination Potential of Pyungtaek-Gun Area, Kyunggi-Do Using GIS (GIS를 이용한 경기도 평택군 지역의 지하수 오염 가능성 평가 연구)

  • 조시범;민경덕;우남칠;이사로
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.87-94
    • /
    • 1999
  • This study is providing Modified DRASTIC Model to which lineament density and land use are added as additional factors using geographic infomation system(GIS). and then to evaluate groundwater contamination potential of Pyungtek-Gun area in Kyunggi-Do. In this study. the reason for using additional factors is because. in case of lineament density. when we consider that most of aquifer is bedrock aquifer in hydrogeologic environment of the Korea, lineament is very important to flow of groundwater and contamination material. and because land use can reflect indirectly impact of point or non_point source in study area. For statistical analysis. vector coverage per each factor is converted to grid layer and after each correlation coefficient between factors, covariance, variance. eigenvalue and eigenvector by principal component analysis of 3 direction. are calculated. correlation between factors is analyzed. Also after correlation coefficients between general DRASTIC layer and rated lineament density layer and between general DRASTIC layer and rated land use layer are calculated. final modified DRASTIC Model is constructed by using them with each weighting. when modified DRASTIC Model was compared with general DRASTIC Model, comtamination potential in modified DRASTIC Model is fairly detailed and consequently. vulnerable area which has high contamination potential could be presented concretly.

  • PDF

Introduction on the Contamination Design Standard(Revision Proposal) of 345kV/154kV Transmission System in KEPCO (345kV/154kV 직접접지계 송전설비의 내오손 설계기준(안) 해설)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Lee, O.B.;Shin, T.W.;Park, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.262-264
    • /
    • 2002
  • This paper shows the design standard of KEPCO on the contamination design for 345 kV and 154 kV transmission tower. Up to now, because the design standard of KEPCO on the insulation design contains 154 kV transmission system only, we had investigated the 343 kV system for the revision of design standard, with respect to the contamination design, we have used the same design philosophy which were adopted to the 765 kV transmission tower. In order to determine the number of insulator discs, we had investigated the withstand voltage of discs according to the level of ESDD(Equivalent Salt Deposit Density) and kinds of disc types. The TOV(Power Frequency Temporary Overvoltage) were estimated by EMTP(Electromagnetic Transient Program) for both 154 kV and 345 kV transmission system. The overvoltage level was appeared 1.35 p.u. between phase to ground for both 154 kV and 345 kV transmission system, but finally this factor was not applied to the design standard considering current design standard and economic point of view. With regard to classification of contamination area of 345 kV transmission system, we added the clean area which was not specified in the current design practise.

  • PDF

Influencing Factors on the Performance of Healthcare-associated Infection Control and Microbiological Hand Contamination among Caregivers at a Tertiary Hospital (일개 상급종합병원에 근무하는 간병인의 의료관련감염 관리 수행도 및 손의 미생물 오염도에 영향을 미치는 요인)

  • Lee, Hee Jin;Park, Eun Ju;Bak, Mi Hui;Ju, Hye Young;Seo, Joo We;Jeon, Mi Yang
    • Journal of muscle and joint health
    • /
    • v.26 no.3
    • /
    • pp.241-250
    • /
    • 2019
  • Purpose: This study was conducted to identify influencing factors on the performance of healthcare-associated infection control and microbiological hand contamination among caregivers at a tertiary hospital. Methods: The participants of this study were 59 caregivers woring at a tertiary hospital. Data were collected from July 1 to 30, 2018. Data were analyzed using descriptive statistics, t-test, ANOVA, Scheffé test, Pearson's correlation coefficients and stepwise multiple regression by SPSS 23.0 Win program. Results: Multiple regression analysis revealed that factors influencing performance of healthcare-associated infection control were awareness (β=.63, p<.001) and the experience of infection-related education (β=-3.40, p=.042). Regression equations describing the performance of healthcare-related infection control were found to be appropriate (F=27.29, p<.001) and accounted for 68% of variance. Factors affecting the degree of microbiological hand contamination were work experience (β=-0.28, p=.026) and healthcare-related infection performance (β=-0.28, p=.029). A regression equation describing the microbiological hand contamination was appropriate (F=6.10, p=.004) and accounted for 42% of variance. Conclusion: The findings of this study suggest that it is necessary to increase performance of healthcare-associated infection control by caregivers. Also, educations for preventing healthcare-associated infection and guidelines for increasing compliance with healthcare-associated infection control are recommended to improve performance of healthcare-associated infection control.

The contamination check before inoculation at the liquid Spawn on Flammulina velutipes (팽나무버섯 액체 종균의 접종 전 오염 검사)

  • Shim, Kyu-Kwang;Yoo, Young-Jin;Koo, Chang-Duck;Kim, Myung-Koon
    • Journal of Mushroom
    • /
    • v.10 no.1
    • /
    • pp.44-48
    • /
    • 2012
  • In this study, whether Giemsa staining solution can accurately determine bacterial contamination of liquid spawn for Flammulina velutipes in a short period of time was investigated. Giemsa solution staining cells of blood, bone marrow, lymph node, malaria parasites, rickettsia et al. was prepared by dissolving basic methylene azul and methylene blue, and acidic eosine in methyl alcohol-glycerine. Supernatant samples of Flammulina velutipes liquid spawn cultured under explosive aeration were placed on a slide, mixed with Gimesa solution and examined with optical microscope after staining. In 40 to 60 seconds bacterial cells were distinguishable from soybean meal residual and hyphal cell fragments. Thus we conclude that microscopy using Gimesa staining solution is a quick, simple and accurate method for the mushroom growers to effectively use to detect bacterial contamination of the liquid spawn.