Evaluation of Oil Pollutants Removal in Seawater as Pretreatment Process for Reverse Osmosis Desalination Process (역삼투식 해수담수화의 전처리공정으로서 유분 제거의 평가)

  • ;Okada Mitsumasa
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.205-209
    • /
    • 2003
  • The various pretreatment processes were evaluated for removal of oil pollutants with weathered oil contaminated seawater in a reverse osmosis desalination process. Weathered oil contaminated seawater was made by biodegradation and photooxidation with oil containing seawater. Coagulation, ultrafiltration, advanced oxidation processes and granular activated carbon filtration was used with pretreatment for dissolved organic carbon. Crude oil was removed but. weathered oil contaminated seawater was not removed by biodegradation and coagulation. DOC and E260 was removed with about 20 % and 40 % by membrane filter of cut off molecular weight 500. So, the most of dissolved organic carbon in weathered oil contaminated seawater was revealed that molecular weight was lower than 500. It is difficult to remove DOC in weathered oil contaminated seawater by advanced oxidation processes treatment, but, E260 was removed more high. However, DOC in weathered oil contaminated seawater was easily adsorbed to GAC. It is revealed that DOC was removed by adsorption.

  • PDF

Design of Robust $\bar{x}$ Control Chart Using a Location Parameter (위치모수를 이용한 로버스트 $\bar{x}$ 관리도의 설계)

  • Chung, Young-Bae;Kim, Yon-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.1
    • /
    • pp.151-156
    • /
    • 2014
  • Control charts are generally used for process control, but the role of traditional control charts have been limited in case of a contaminated process. Traditional $\bar{x}$ control charts have not been activated well for such a problem because of trying to control processes as center line and control limits changed by the contaminated value. This paper is to propose robust $\bar{x}$ control charts which is considering a location parameter in order to respond to contaminated process. In this paper, we consider $\bar{x}_{\alpha}$, that is trimmed rate; typically ten percent rate is used. By comparing with p, ARL value, the responding results are decided. The comparison resultant results of proposed two control charts are shown and are well contrasted.

Control of Contaminants Elution by Solidification of Contaminated Soil (오염토양의 고형화에 따른 오염물질 용출제어)

  • Chung, Ha-Ik;Cho, Jin-Woo;Yu, Jun;Lee, Yong-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.739-742
    • /
    • 2002
  • Immobilization of contaminants in contaminated soils by solidification processes is an attractive potential remediation process. In this study, the treatability of lead, copper, toluene, and COD was investigated by leaching test. Industrial sand was adopted as the test material and was contaminated with lead copper, and toluene to 100mg/kg, 500mg/kg, 200mg/kg respectively. P solidifying agent was used as the binder(20% by weight of contaminated soil) in the solidification treatment. The leachability of contaminants leached from the solidified soil was evaluated using column test. The percentage of contaminants leached from the solidified soil was significantly reduced by reaction of waste species with cement components and encapsulation reaction of binder. Based on the tests, it is ascertained solidification process can be a very effective method to control the elution of contaminants from the contaminated soil.

  • PDF

Some Process Capability Indices Using Loss Function Under Contaminated Normal Process (혼합 정규공정하에서 손실함수를 이용한 공정능력지수)

  • 김평구;조중재
    • Journal of Korean Society for Quality Management
    • /
    • v.26 no.4
    • /
    • pp.65-78
    • /
    • 1998
  • Process capability indices, used to determine whether a production process is capable of producing items within a specified tolerance, have been widely used in process assessments. In this paper, we consider some process capability indices using loss function when process is contaminated normal. Also, we examine some small sample properties related to these estimaters by some simulations.

  • PDF

Evaluation of Remediation of Contaminated Soil Using PVDs (연직배수재를 이용한 오염도턍복원 특성 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun;Roh, Jeong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1400-1407
    • /
    • 2005
  • There are a number of approaches to in situ remediation that are used at contaminated sites for removing contaminants from the contaminated zone without excavating the soil. These include soil flushing, dual phase extraction, and soil vapor extraction. Of these techniques, soil flushing is the focus of the investigation in this paper. The concept of using prefabricated vertical drains(PVDs) for remediation of contaminated sites with fine-grained soils is examined. The PVD system is used to shorten the drainage path or the groundwater flow and promote subsurface liquid movement expediting the soil flushing process. The use of PVDs in the current state of practice has been limited to soil improvement. The use of PVDs under vacuum conditions is investigated using sample soil consisting of silty sand.

  • PDF

A Continuous Process of Persulfate Oxidation and Citric acid Washing for the Treatment of Complex-Contaminated Soil Containing Total Recoverable Petroleum Hydrocarbons and Heavy Metals (TRPHs - 중금속 복합오염토양의 동시 처리를 위한 과황산 산화 - 구연산 세척 혼성공정 개발)

  • Yoon, Na Kyeong;Choi, Jiyeon;Shin, Won Sik
    • Journal of Environmental Science International
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • A continuous process of persulfate oxidation and citric acid washing was investigated for ex-situ remediation of complex contaminated soil containing total recoverable petroleum hydrocarbons (TRPHs) and heavy metals (Cu, Pb, and Zn). The batch experiment results showed that TRPHs could be degraded by $Fe^{2+}$ activated persulfate oxidation and that heavy metals could be removed by washing with citric acid. For efficient remediation of the complex contaminated soil, two-stage and three-stage processes were evaluated. Removal efficiency of the two-stage process (persulfate oxidation - citric acid washing) was 83% for TRPHs and 49%, 53%, 24% for Cu, Zn, and Pb, respectively. To improve the removal efficiency, a three-stage process was also tested; case A) water washing - persulfate oxidation - citirc acid washing and case B) persulfate oxidation - citric acid washing (1) - citric acid washing (2). In case A, 63% of TRPHs, 73% of Cu, 60% of Zn, and 55% of Pb were removed, while the removal efficiencies of TRPHs, Cu, Pb, and Zn were 24%, 68%, 62%, and 59% in case B, respectively. The results indicated that case A was better than case B. The three-stage process was more effective than the two-stage process for the remediation of complex-contaminated soil in therms of overall removal efficiency.

A Study of a Combined Microwave and Thermal Desorption Process for Contaminated Soil

  • Ha, Sang-An;Choi, Kyoung-Sik
    • Environmental Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.225-230
    • /
    • 2010
  • In order to treat soil contaminated with high percentages of water and petroleum, the combined microwave and thermal desorption process was studied, which was composed of the consecutive connection of two pre-treatment processes. For the thickness of the contaminated soil layer on the transfer conveyor belt, the optimal total petroleum hydrocarbon (TPH) removal rate was studied with respect to the duration of microwave exposure in the consecutive process combined with thermal desorption. The TPH removal rate when the contaminated soil layer thickness was 1 cm at 6 kW of microwave power was 80%. The removals rates for 2 and 3 cm soil layer thicknesses were both 70%. Under identical experimental conditions, the TPH removal rate for the microwave pre-treatment, when considering the soil particle size, was over 70%. The lowest TPH removal rate was achieved with a particle diameter of 2.35 mm. For contaminated soil with 30% water content, 6 kW and a thermal desorption temperature of $600^{\circ}C$ were the optimal operational conditions for the removal of THP. However, considering the fuel consumption cost, 4 kW and a thermal desorption temperature of $300^{\circ}C$ would be the most economic conditions.

Enhanced Separation Technique of Heavy Metal (Pb, Zn) in Contaminated Agricultural Soils near Abandoned Metal Mine (폐금속 광산지역 농경지 납, 아연 오염 토양의 중금속 고도선별)

  • Park, Chan Oh;Kim, Jin Soo;Seo, Seung Won;Lee, Young Jae;Lee, Jai Young;Park, Mi Jeong;Kong, Sung Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.7
    • /
    • pp.41-53
    • /
    • 2013
  • The study is to propose the optimal separation technique of heavy metals (Pb and Zn) contaminated in soil for improving the removal efficiency by various applicable techniques. The heavy metal contaminated soil samples near abandoned mine X-1 and X-2 were used for the study. Firstly, the wet classification process was shown more than 80% of removal efficiency for lead and zinc. Meanwhile, the magnetic separation process was shown low removal efficiency for lead and zincs because those heavy metals were non-magnetic materials. For the next step, the flotation separation process was shown approximately 24.4% of removal efficiency for zinc, while the gravity concentration process was shown approximately 57% of removal efficiency for lead, and 19.9% of removal efficiency for zinc, respectively. Therefore, zinc contaminated in soil would be effectively treated by the combination technique of the wet classification and the flotation technique. Meanwhile, lead contaminated in soil would be effectively treated by the combination technique of the wet classification process and the flotation process. Furthermore, the extraction of organic matter was shown more effective with aeration, 3% of hydrogen peroxide and 3% of lime such as calcium hydroxide.

Effect of Heavy Metal Species on the Removal of Cu, Pb, and Cd Contaminated Soils Using Electrokinetic Process (Cu, Pb, 및 Cd로 오염된 토양의 동전기적 방법에 의한 제거에 있어 중금속 종이 미치는 영향)

  • Sin, Hyeon Mu;Yun, Sam Seok
    • Journal of Environmental Science International
    • /
    • v.13 no.1
    • /
    • pp.61-68
    • /
    • 2004
  • Three kinds of toxic heavy metals, such as lead, copper, and cadmium, existing abundantly in contaminated soils were selected to investigate pH change, electroosmotic flow, and the removal rate in the application of electrokinetic process. In the change of pHs, they reached to about 12 and 2 at each cathodic and anodic region, respectively, and maintained for reaction being proceeded. Electroosmotic flow rates were not influenced by the kind of metal species but by electropotential gradient. On the soils contaminated by each metal, the removal rate of Cd was the fastest among three as in the order of Cd>Pb>Cu. While on the soils contaminated by mixed metal species, Cu was the fastest. Metal species transported by electrokinetic processes were distributed in between 0.9 and 1.0 of normalized region. In the case of soils contaminated by one kind of metal. the relative concentrations of Pb and Cd estimated in between normalized region 0.9 and 1.0 were 5.2 and 5.7, respectively.

The Design of Robust Control Chart for A Contaminated Process (오염된 공정을 위한 로버스트 관리도의 설계)

  • Kim, Yong-Jun;Kim, Dong-Hyuk;Chung, Young-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.3
    • /
    • pp.327-336
    • /
    • 2012
  • Purpose: In this study, we research the hurdle rate method to suggest the robust control chart for a contaminated process less vulnerable to fault values than existing control charts. Methods: We produce the results of p, ARL values to compare the performance of two control charts, $\bar{x}-s$ that has been used typically and TM-TS that is suggested by this paper. We implement the simulation focusing on three cases, change of deviation, mean and both of them. Results: We draw a conclusion that the TM-TS control chart has better efficiency than $\bar{x}-s$ control chart over the three cases. Conclusion: We insist that applying TM-TS control chart for a polluted process is more effective than $\bar{x}-s$ control chart.