• Title/Summary/Keyword: Container Image

Search Result 115, Processing Time 0.089 seconds

Development of Defect Inspection System for Polygonal Containers (다각형 용기의 결함 검사 시스템 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.485-492
    • /
    • 2021
  • In this paper, we propose the development of a defect inspection system for polygonal containers. Embedded board consists of main part, communication part, input/output part, etc. The main unit is a main arithmetic unit, and the operating system that drives the embedded board is ported to control input/output for external communication, sensors and control. The input/output unit converts the electrical signals of the sensors installed in the field into digital and transmits them to the main module and plays the role of controlling the external stepper motor. The communication unit performs a role of setting an image capturing camera trigger and driving setting of the control device. The input/output unit converts the electrical signals of the control switches and sensors into digital and transmits them to the main module. In the input circuit for receiving the pulse input related to the operation mode, etc., a photocoupler is designed for each input port in order to minimize the interference of external noise. In order to objectively evaluate the accuracy of the development of the proposed polygonal container defect inspection system, comparison with other machine vision inspection systems is required, but it is impossible because there is currently no machine vision inspection system for polygonal containers. Therefore, by measuring the operation timing with an oscilloscope, it was confirmed that waveforms such as Test Time, One Angle Pulse Value, One Pulse Time, Camera Trigger Pulse, and BLU brightness control were accurately output.

Evaluation of the Utilization Potential of High-Resolution Optical Satellite Images in Port Ship Management: A Case Study on Berth Utilization in Busan New Port (고해상도 광학 위성영상의 항만선박관리 활용 가능성 평가: 부산 신항의 선석 활용을 대상으로)

  • Hyunsoo Kim ;Soyeong Jang ;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_4
    • /
    • pp.1173-1183
    • /
    • 2023
  • Over the past 20 years, Korea's overall import and export cargo volume has increased at an average annual rate of approximately 5.3%. About 99% of the cargo is still being transported by sea. Due to recent increases in maritime cargo volume, congestion in maritime logistics has become challenging due to factors such as the COVID-19 pandemic and conflicts. Continuous monitoring of ports has become crucial. Various ground observation systems and Automatic Identification System (AIS) data have been utilized for monitoring ports and conducting numerous preliminary studies for the efficient operation of container terminals and cargo volume prediction. However, small and developing countries' ports face difficulties in monitoring due to environmental issues and aging infrastructure compared to large ports. Recently, with the increasing utility of artificial satellites, preliminary studies have been conducted using satellite imagery for continuous maritime cargo data collection and establishing ocean monitoring systems in vast and hard-to-reach areas. This study aims to visually detect ships docked at berths in the Busan New Port using high-resolution satellite imagery and quantitatively evaluate berth utilization rates. By utilizing high-resolution satellite imagery from Compact Advanced Satellite 500-1 (CAS500-1), Korea Multi-Purpose satellite-3 (KOMPSAT-3), PlanetScope, and Sentinel-2A, ships docked within the port berths were visually detected. The berth utilization rate was calculated using the total number of ships that could be docked at the berths. The results showed variations in berth utilization rates on June 2, 2022, with values of 0.67, 0.7, and 0.59, indicating fluctuations based on the time of satellite image capture. On June 3, 2022, the value remained at 0.7, signifying a consistent berth utilization rate despite changes in ship types. A higher berth utilization rate indicates active operations at the berth. This information can assist in basic planning for new ship operation schedules, as congested berths can lead to longer waiting times for ships in anchorages, potentially resulting in increased freight rates. The duration of operations at berths can vary from several hours to several days. The results of calculating changes in ships at berths based on differences in satellite image capture times, even with a time difference of 4 minutes and 49 seconds, demonstrated variations in ship presence. With short observation intervals and the utilization of high-resolution satellite imagery, continuous monitoring within ports can be achieved. Additionally, utilizing satellite imagery to monitor changes in ships at berths in minute increments could prove useful for small and developing country ports where harbor management is not well-established, offering valuable insights and solutions.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

3-Dimensional Verification Technique for Target Point Error (자기공명영상기반 겔 선량측정법을 이용한 3차원적 목표 중심점 점검기술)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose gel dosimeter based verification technique for 3-dimensional target point error. The phantom was made for simulation of human head and this has ability to equip 10 gel-dosimeter. $BANGkit^{TM}$ which we are able to manufacture whenever it is needed as well as to easily change the container with different shapes was used as a gel dosimeter. The 10 targets were divided into two groups based on shapes of areas with a planned 50% isodose line. All treatment and analysis was performed three times using Novalis and $BrainSCAN^{TM}$. The target point error is $0.77{\pm}0.15mm$ for 10 targets and directional target point error in each direction is $0.54{\pm}0.23mm$, $0.37{\pm}0.08mm$, $0.33{\pm}0.10mm$ in AP (anterior-posterior), LAT (lateral), and VERT (vertical) direction, respectively. The result of less than 1 mm shows that the treatment was performed through each precise step in treatment procedure. In conclusion, the 3-dimensional target point verification technique can be one of the techniques for overall system test.

THE EFFECT OF FLUORIDE VARNISH AND ACIDULATED PHOSPHATE FLUORIDE GEL ON ARTIFICIAL CARIES LESION - A MICROCOMPUTED TOMOGRAPHIC STUDY - (Fluoride Varnish와 Acidulated Phosphate Fluoride Gel이 인공우식 병소에 미치는 영향에 대한 미세전산화 단층 촬영을 이용한 연구)

  • Moon, Sung-Kwon;Lee, Jae-Cheoun;Kim, Young-Jae;Lee, Sang-Hoon;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.212-222
    • /
    • 2004
  • The application of acidulated phosphate fluoride gel(APF) and fluoride varnishes are the most common topical fluoride therapy. The purpose of this in vitro study was to compare the remineralization effects of two topical fluoride agents, APF gel and fluoride varnish with microtomograph and 3D image analyzer without sample preparation and chemical fixation. For the purpose of the study, the artificial caries lesion was caused on the caries-free permanent pre molar and 48 specimens were divided into three groups each containing 16 specimens No application was performed on group 1, which acted as control group. Group 2 was treated with APF gel and was removed after a minute. Group 3 was treated with the topical application of fluoride varnish and removed after 45 minutes. Each specimen was placed into a closed container with 50ml of a artificial saliva during three months and the 3D images of the remineralization area were taken using the SkyScan each month. Using the density-measuring program in V $works^{TM}$, the density value of the remineralization area was measured. The following results were obtained: 1. All groups demonstrated an increase in the density of artificial caries lesion with time. 2. The density was significantly higher in APF gel and fluoride varnish group than control group at 1 month, 2 months, 3 months after the treatment(P<0.05). 3. The difference of the density between that "prior to treatment" and that "1 month after treatment" in Group 2 and Group 3 was significantly higher than that of Group 1 and, the difference of the density between that "1 month after treatmen" and that "2 month after treatment" in Group 3 was significantly higher than that of Group 1 and 2(P<0.05). 4. The fluoride varnish was more effective after 2 and 3 months and continuous than the APF gel.

  • PDF