• Title/Summary/Keyword: Contact pressure

Search Result 1,703, Processing Time 0.031 seconds

Preparation of PVA/Graphene Oxide/Fe3O4 Magnetic Microgels as an Effective Adsorbent for Dye Removal (폴리바이닐알코올/그래핀 옥사이드/산화철 자성 마이크로겔을 이용한 염료 제거)

  • Go, Seongmoon;Kim, Keunseong;Wi, Eunsol;Park, Rae-Su;Jung, Hong-Ryun;Yun, Changhun;Chang, Mincheol
    • Composites Research
    • /
    • v.35 no.2
    • /
    • pp.98-105
    • /
    • 2022
  • In this study, polyvinyl alcohol (PVA)/graphene oxide (GO)/iron oxide (Fe3O4) magnetic microgels were prepared using a microfluidic approach and the dye adsorption capacity of the microgels was confirmed. The adsorption capacity (qe) of the gels was evaluated by varying the dye concentration, pH, and contact time with the microgels. The dyes used in this work were methylene blue (MB), crystal violet (CV), and malachite green (MG), and microgels showed the highest adsorption capacity (191.1 mg/g) in methylene blue. The microgels exhibited the highest adsorption capacity in the dye aqueous solution at pH 10 due to the presence of atomic nitrogen ions (N+) on the dye molecules. The adsorption isotherm studies revealed that the Langmuir isotherm is the best fit isotherm model for the dye adsorption on the microgels, indicative of monolayer adsorption. The kinetic analysis exhibited that the pseudo-second order model fits better than the pseudo-first order model, confirming that the adsorption process is chemisorption. In addition, the magnetic microgels showed good reusability and recovery efficiency. It was confirmed that the adsorption capacity of the gels maintains more than 70% of the initial capacity after 5 times of cycle experiments.

Effects of Dynamic Tubing Gait Training on Postural Alignment, Gait, and Quality of Life in Chronic Patients with Parkinson's Disease : Case Study (동적탄력튜빙 보행훈련 프로그램이 만성 파킨슨병 환자의 자세정렬과 보행능력과 삶의 질에 미치는 영향 : 사례연구)

  • Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.363-377
    • /
    • 2021
  • The present study investigated the effects of dynamic tubing gait training(I and II) on the postural alignment, gait, and quality of life in chronic patients with Parkinson's disease. This study is based on the case study that recruited a total of 3 patients with chronic Parkinson's disease (Hoehn and Yahr Stage of 1 to 3 each one person). Dynamic tubing gait training (I and II) applied to chronic patients with Parkinson's disease for 25 sessions, 30 minutes a day, 5 days a week, over 5 weeks period. To investigate the effects of this study, evaluating using the postural alignment test, muscle activity tests, gait analysis, and quality of life scale for patient with Parkinson's disease. After the intervention of Dynamic tubing gait training (I and II), Trunk flexion was decreased. Also, during walking from initial contact (IC) to mid stance (Mst), muscle activity of Quadriceps, Hamstring, and Tibialis Anterior (TA) was increased and muscle activity of Gastrocnemius was decreased. The muscle activation of Erector Spinae (ES T12, L3) was increased in the H&Y I and III stages and decreased in the H&Y II stage. Length of gait line, single support line, ant/post position and lateral symmetry of center of pressure (COP) parameters improved. The spatio-temporal gait parameters including of step length, stride length, and velocity was increased, and cadence decreased. Further the quality of life of patients with Parkinson's disease was improved. Based on these findings, Dynamic tubing gait training (I and II) could be applied as a new approach to improve posture, gait, quality of life in chronic patients with Parkinson's disease for more than 5 years, whose drug resistance is halved.

Correlation and Spatial Analysis between the number of Confirmed Cases of the COVID-19 and Traffic Volume based on Taxi Movement Data (택시 이동 데이터 기반 COVID-19 확진자 수와 교통량 간의 상관관계 및 공간분석)

  • Jeon, Seung Bae;Kim, Geon;Jeong, Myeong-hun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.609-618
    • /
    • 2021
  • The spread and damage of COVID-19 are putting significant pressure on the world, including Korea. Most countries place restrictions on movement and gathering to minimize contact between citizens and these policies have brought new changes to social patterns. This study generated traffic volume data on the scale of a road network using taxi movement data collected in the early stages of the COVID-19 third pandemic to analyze the impact of COVID-19 on movement patterns. After that, correlation analysis was performed with the data of confirmed cases in Daegu Metropolitan City and Local Moran's I was applied to analyze the effect of spatial characteristics. As a result, in terms of the overall road network, the number of confirmed cases showed a negative correlation with taxi driving and at least -0.615. It was confirmed that citizens' movement anxiety was reflected as the number of confirmed cases increased. The commercial and industrial areas in the center of the city confirmed the cold spot with a negative correlation and low-low local Mona's I. However, the road network around medical institutions such as hospitals and spaces with spatial characteristics such as residential complexes was high-high. In the future, this analysis could be used for preventive measures for policymakers due to COVID-19.

Evaluation of Water Quality Change by Membrane Damage to Pretreatment Process on SDI in Wastewater Reuse (하수재이용에서 전처리 막 손상에 의한 수질변화가 SDI에 미치는 영향평가)

  • Lee, Min Soo;Seo, Dongjoo;Lee, Yong-Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.253-263
    • /
    • 2022
  • This study suggests a guideline for designing unit process of wastewater reuse in terms of a maintenance of the process based on critical parameters to draw a high quality performance of RO unit. Defining the parameters was done by applying membrane integrity test (MIT) in pretreatment process utilizing lab-scale MF. SDI is utilized for judging whether permeate is suitable to RO unit. However, result said TOC concentration matching with particle count analysis is better for judging the permeate condition. When membrane test pressure (Ptest) was measured to derive log removal value in PDT, virgin state of membrane fiber was used to measure dynamic contact angle utilizing surface tension of the membrane fiber. Actually, foulant affects to the state of membrane surface, and it decreases the Ptest value along with time elapsed. Consequently, LRVDIT is also affected by Ptest value. Thus, sensitivity of direct integrity test descends with result of Ptest value change, so Ptest value should be considered not the virgin state of the membrane but its current state. Overall, this study focuses on defining design parameters suitable to MF pretreatment for RO process in wastewater reuse by assessing its impact. Therefore, utilities can acknowledge that the membrane surface condition must be considered when users conduct the direct integrity test so that Ptest and other relative parameter used to calculate LRVDIT are adequately measured.

Repair of Plasma Damaged Low-k Film in Supercritical Carbon Dioxide (초임계이산화탄소를 이용한 플라즈마 손상된 다공성 저유전 막질의 복원)

  • Jung, Jae-Mok;Lim, Kwon-Taek
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.191-197
    • /
    • 2010
  • Repair reaction of plasma damaged porous methyl doped SiOCH films was carried out with silylation agents dissolved in supercritical carbon dioxide ($scCO_2$) at various reaction time, pressure, and temperature. While a decrease in the characteristic bands at $3150{\sim}3560cm^{-1}$ was detectable, the difference of methyl peaks was not identified apparently in the FT-IR spectra. The surface hydrophobicity was rapidly recovered by the silylation. In order to induce effective repair in bulk phase, the wafer was heat treated before reaction under vacuum or ambient condition. The contact angle was slightly increased after the treatment and completely recovered after the subsequent silylation. Methyl groups were decreased after the plasma damage, but their recovery was not identified apparently from the FT-IR, spectroscopic ellipsometry, and secondary ion mass spectroscopy analyses. Furthermore, Ti evaporator was performed in a vacuum chamber to evaluate the pore sealing effect. The GDS analysis revealed that the open pores in the plasma damaged films were efficiently sealed with the silylation in $scCO_2$.

Centrifuge Model Tests on Trafficability of Very Soft Ground Treated with Geotextile and Sand Mat (토목섬유와 모래로 처리된 초연약지반의 장비주행성에 대한 원심모형실험)

  • Jun, Sang-Hyun;Lee, Jong-Ho;Yoo, Nam-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.3
    • /
    • pp.13-23
    • /
    • 2010
  • In this study, centrifuge model tests with 50 g gravitational condition were performed to evaluate the bearing capacity of very soft ground, improved by spreading geotextile and sand on the surface of ground, for the heavy machinery to be able to access. For undrained shear strength of ground model, prepared with the clay sampled from the field, being in the range of 3.1~11.7 kPa, bearing capacity tests were performed with the model footing and the loading system built to simulate the heavy machinery on the ground model treated with geotextile and sand. Test results were compared with theoretically and numerically evaluated ones. Test results about load-settlement curves showed that the bearing capacity increases with the increase of the undrained shear strength of ground. Punching shear or local shear failure was also observed. For a relatively low undrained shear strength of ground, settlement behavior is found to be crucial to evaluating the trafficability of machinery whereas bearing capacity becomes a dominant factor with the increase of undrained shear strength of ground. The method for assessing the bearing capacity of the ground related to trafficability of machinery is presented by acquiring the regression relationship between the contact pressure of machinery and settlements using load-settlement curves with the change of the undrained shear strength. Furthermore, results of numerical analyses about load-settlement relation are in relatively good agreement with those of centrifuge model test.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

Identifying Analog Gauge Needle Objects Based on Image Processing for a Remote Survey of Maritime Autonomous Surface Ships (자율운항선박의 원격검사를 위한 영상처리 기반의 아날로그 게이지 지시바늘 객체의 식별)

  • Hyun-Woo Lee;Jeong-Bin Yim
    • Journal of Navigation and Port Research
    • /
    • v.47 no.6
    • /
    • pp.410-418
    • /
    • 2023
  • Recently, advancements and commercialization in the field of maritime autonomous surface ships (MASS) has rapidly progressed. Concurrently, studies are also underway to develop methods for automatically surveying the condition of various on-board equipment remotely to ensure the navigational safety of MASS. One key issue that has gained prominence is the method to obtain values from analog gauges installed in various equipment through image processing. This approach has the advantage of enabling the non-contact detection of gauge values without modifying or changing already installed or planned equipment, eliminating the need for type approval changes from shipping classifications. The objective of this study was to identify a dynamically changing indicator needle within noisy images of analog gauges. The needle object must be identified because its position significantly affects the accurate reading of gauge values. An analog pressure gauge attached to an emergency fire pump model was used for image capture to identify the needle object. The acquired images were pre-processed through Gaussian filtering, thresholding, and morphological operations. The needle object was then identified through Hough Transform. The experimental results confirmed that the center and object of the indicator needle could be identified in images of noisy analog gauges. The findings suggest that the image processing method applied in this study can be utilized for shape identification in analog gauges installed on ships. This study is expected to be applicable as an image processing method for the automatic remote survey of MASS.

Development of a hip model for impact testing of bedsore prevention cushions (욕창예방 방석의 충격시험용 둔부 모형 개발)

  • JUNG, SUNGBAE;YUK, SUNWOO;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.7-11
    • /
    • 2024
  • The bedsore prevention cushion serves to prevent the skin on the buttocks of a wheelchair user from being damaged through friction with the wheelchair seat. This is because it absorbs some of the weight applied to the wheelchair seat and allows the weight to be applied evenly to the entire contact surface. For the impact test, which is part of the performance testing of bedsore prevention cushions, a hip model that represents the sitting posture of a wheelchair user is required. In this study, a hip model was manufactured for impact testing of bedsore prevention cushions for wheelchairs. Performance tests for pressure bedsore prevention cushions for wheelchairs include KSP 0236, a Korean standard, and KS P ISO 16840-2, an ISO international standard. The hip model proposed in KS P ISO 16840-2 was more suitable for impact testing of bedsore prevention cushions for wheelchairs. However, the guidelines for making hip models proposed by international standards need to be modified to reflect the advancement of model making technology and use easier methods. We propose a new hip model production method that produces a hip model out of plastic all at once and additionally attaches SS-41 steel plates processed into the shape of the hip to make the mass of the model similar to the human body.

The Survey of Dentists: Updated Knowledge about Basic Life support and Experiences of Dental Emergency in Korea

  • Cho, Kyoung-Ah;Kim, Hyuk;Lee, Brian Seonghwa;Kwon, Woon-Yong;Kim, Mi-Seon;Seo, Kwang-Suk;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.1
    • /
    • pp.17-27
    • /
    • 2014
  • Background: Various medical emergency situations can occur during dental practices. Cardiac arrest is known to comprise approximately 1% of emergency situation. Thus, it is necessary for dentists to be able to perform cardiopulmonary resuscitation (CPR) to increase the chance of saving patient's life in emergency situation. In this paper, we conducted a survey study to evaluate to what extent dentists actually understood CPR practice and if they had experience in handling emergency situations in practice. Method: The survey was done for members of the Korean Dental Society of Anesthesiology (KDSA), who had great interest in CPR and for whom survey-by-mail was convenient. We had selected 472 members of the KDSA with a dental license and whose office address and contact information were appropriate, and sent them a survey questionnaire by mail asking about the degree of their CPR understanding and if they had experience of handling emergency questions before. Statistical analyses -frequency analysis, chi-square test, ANOVA, and so on- were performed by use of IBM SPSS Statistics 19 for each question. Result: Among 472 people, 181 responded (38.4% response rate). Among the respondents were 134 male and 47 female dentists. Their average age was $40.4{\pm}8.4$. In terms of practice type, there were 123 private practitioners (68.0%), 20 professors (11.0%), 16 dentists-in-service (8.8%), 13 residents (specialist training) (7.2%) and 9 military doctors (5%). There were 125 dentists (69.1%) who were specialists or receiving training to be specialist, most of whom were oral surgeon (57, 31.5%) and pediatric dentists (56, 30.9%). There were 153 people (85.0%) who received CPR training before, and 65 of them (35.9%) were receiving regular training. When asked about the ratio of chest pressure vs mouth-to-mouth respiration when conducting CPR, 107 people (59.1%) answered 30:2. However, only 27.1% of them answered correctly for a question regarding CPR stages, C(Circulation)- A(Airway)- B(Breathing)- D(Defibrillation), which was defined in revised 2010 CPR practice guideline. Dentists who had experience of handling emergency situations in their practice were 119 (65.6%). The kinds of emergency situations they experienced were syncope (68, 37.6%), allergic reactions to local anesthetic (44, 24.3%), hyperventilation (43, 23.8%), seizure (25, 13.8%), hypoglycemia (15, 8.3%), breathing difficulty (14, 7.8%), cardiac arrest (11, 6.1%), airway obstruction (6, 3.3%), intake of foreign material and angina pectoris (4, 2.2%), in order of frequency. Most respondents answered that they handled the situation appropriately under the given emergency situation. In terms of emergency equipment they had blood pressure device (70.2%), pulse oximetry (69.6%), Bag-Valve-Mask (56.9%), emergency medicine (41.4%), intubation kit (29.8%), automated external defibrillator (23.2%), suction kit (19.3%) and 12 people (6.6%) did not have any equipment. In terms of confidence in handling emergency situation, with 1-10 point scale, their response was $4.86{\pm}2.41$ points. The average point of those who received regular training was $5.92{\pm}2.20$, while those who did not was $4.29{\pm}2.29$ points (P<0.001) Conclusion: The result showed they had good knowledge of CPR but the information they had was not up-to-date. Also, they were frequently exposed to the risk of emergency situation during their dental practice but the level of confidence in handling the emergency situation was intermediate. Therefore, regular training of CPR to prepare them for handling emergency situation is deemed necessary.