• Title/Summary/Keyword: Contact lens

Search Result 397, Processing Time 0.024 seconds

Full Contact Polishing Method of Aspherical Glass Lens Mold by Airbag Polishing Tool (에어백 공구에 의한 비구면 유리 렌즈 금형의 전면 접촉 연마)

  • Lee, Ho-Cheol;Kim, Jung-Uk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.5
    • /
    • pp.82-88
    • /
    • 2008
  • Conventional aspherical lens polishing methods by the small tool polishing use aspherical profile and the trajectory of the polishing tool is also controlled. In this paper, new full contact polishing mechanism is suggested to polish aspherical glass lens mold by both airbag polishing tool and eccentric motion. Full contact concept by airbag polishing tool and no position control make the easy polishing setup and do not need aspherical design profile. An aspherical lens polishing machine was made for this study and a verification experiment was performed for surface roughness improvements.

The Relationship between Habitual Patient-Reported Symptoms and Signs in the Soft Contact Lens Wearers (소프트 콘택트렌즈 착용자에서 평상시 나타난 증상에 관한 연구)

  • Lee, Koon-Ja;Buyn, Jang-Won;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2008
  • Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.

  • PDF

An Excel Program for Dk Calculation of Contact Lens (엑셀 프로그램을 이용한 콘택트렌즈의 Dk 결정)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2011
  • Purpose: The review article was written to establish an excel program that could calculate minimal Dk of contact lens without $O^2$ deficiency and actual $O^2$ concentration on cornea when contact lens were being fitted by changing lens-related factors. Methods: An excel program was formulated to calculate the thickness of post-lens lacrimal layer, Dk of contact lens and $O^2$ concentration on cornea. Results: With the excel program established, minimal $O^2$ concentration needed on cornea could be calculated when the thickness of post-lens lacrimal layer was changed by varying lens-related factors. A different route in the excel program was needed to choose based on the shape of lacrimal layer. The thickness of lacrimal layer was determined by the shape of meniscus made of tear between lens edge and cornea with flat fit. Thus, the $O^2$ concentration showing negative number in calculation decreased on peripheral cornea with flatter fitting and actual $O^2$ concentration would be zero on cornea. With tight fitting, the thickness of post-lens lacrimal layer is much thicker than lens itself thus negative number in calculation by the excel program is shown indicating zero oxygen on cornea. It can cause $O^2$ deficiency regardless of Dk of contact lens. Conclusions: The calculation of thickness of post-lens lacrimal layer and $O^2$ concentration on cornea by the established excel program is suggested to avoid $O^2$ deficiency when fitting state is varied by changing lens-related factors.

Polymerization and Preparation of Functional Ophthalmic Material Containing Carbon Nanoparticles

  • Lee, Min-Jae;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.28 no.8
    • /
    • pp.452-458
    • /
    • 2018
  • This research is conducted to create a functional hydrogel ophthalmic lens containing nanoparticles. Carbon nanoparticles and PEGMEMA are used as additives for the basic combination of HEMA, MA, and MMA, and the materials are copolymerized with EGDMA as the cross-linking agent and AIBN as the thermal initiator. The hydrogel lens is produced using a cast-mold method, and the materials are thermally polymerized at $100^{\circ}C$ for an hour. The polymerized lens sample is hydrated in a 0.9 % saline solution for 24 hours before the optical and physical characteristics of the lens are measured. The refractive index, water content, contact angle, light transmittance, and tensile strength are measured to evaluate the physical and optical characteristics of the hydrogel lens. The refractive index, water content, contact angle, UV-B light transmittance, UV-A light transmittance, visible light transmittance, tensile strength and breaking strength of the hydrogel lens polymer are 1.4019~1.4281, 43.05~51.18 %, $31.95{\sim}68.61^{\circ}$, 21.69~58.11 %, 35.59~84.26 %, 45.85~88.06 %, 0.1075~0.1649 kgf and 0.1520~0.2250 kgf, respectively. The results demonstrate an increase in refractive index, tensile strength and breaking strength and a decrease in contact angle and light transmittance. Furthermore, the visible light transmissibility is significantly increased at PEG 10 %. It is clear that this material can be used for high-performance ophthalmic lenses with wettability, ultraviolet ray blocking effect, and tensile strength.

A Convergence Study on Wearing Contact Lenses after Corneal Refractive Surgery (각막굴절수술 후 콘택트렌즈 착용에 대한 융복합적 연구)

  • Park, Hye-Won
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.8
    • /
    • pp.117-125
    • /
    • 2018
  • Aims of this study was to investigate on the actual condition of contact lens wearing after corneal refractive surgery, base curves and diameters of lenses on sale, and to confirm movement of lens and wear patterns when wearing of lenses in the modified cornea. After surgery, 16.5% of the respondents had experience wearing contact lenses. Also, the mostly distributed contact lenses had B.C. 8.6mm and DIA.14.0mm. The corneas of 24 eye after corneal refractive surgery were flat, the lenses moved towards inferior and temporal when wearing the lens. After corneal refractive surgery, contact lens wear may feel uncomfortable may require the detailed description and sophisticated fitting due to the limited type of contact lens. It is thought that convergence will be necessary in the industry and clinical study of contact lenses.

A Study of the Effects of Use upon RGP Contact Lens Surface Ultrastructure (RGP Contact Lens 표면 미세구조에 대한 사용 효과의 연구)

  • Kim, Douk-Hoon;Sung, A-Young;Crossman, Stanley
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.71-75
    • /
    • 2006
  • The aim of this study was to analyze the surface ultrastructure of RGP contact lenses post-use The RGP contact lenses, to investigate, were selected after one month, six months and one year of wear by the subjects. The anterior and posterior surfaces of these RGP contact lenses were inspected by a scanning electron microscope. The results were the following: 1. After one month of RGP contact lens use the anterior and posterior surfaces appeared clean and clear as originally. 2. After six months the anterior surface had several scars, dips, cracks and scratches. Upon the posterior surface appeared several foreign bodies and microorganisms. 3. After one year there was large scale damage and many foreign bodies were observed. Therefore, extended use of RGP contact lenses has shown increasing physical damage and extensive foreign body accumulation upon the ultrastructure of the lens surface.

  • PDF

Review on the fabrication method and characteristics of colored contact lens (칼라콘택트렌즈의 제조 - 제조방법과 특성에 대해 -)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.127-132
    • /
    • 2005
  • Beginning the use of medical order with color contact lens, recently the color contact lens wearer increases for cosmetic order in the world. The marufacture of color contact lenses was the pigment application method, the pigment inlay method, the sandwich method, the vinding method, and so on. Now in domestic, the main use of manufacture has been the binding method. In the point of the use and manufacture of the color contact lenses, the classification of color contact lenses was the tinted and the cosmetic types. However the generally coloring of color contact lenses was the stain-method and the staining was marufactured by the thin film methods.

  • PDF

Changes of Refractive Correction Value with Different Age Group: A Case for Myopia Control Lens, Single Vision Lens and Reverse Geometry Contact Lens (Myopia Control Lens, Single Vision Lens, Reverse Geometry Contact Lens의 연령에 따른 굴절교정상태 변화에 대한 추적 연구)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.75-84
    • /
    • 2013
  • Purpose: Changes of refractive correction value in different age group were investigated. Regarding the inhibitive effects against myopia progression after wearing reverse geometry contact lenses and myopia control lenses (MC lenses), the effects after wearing single vision lenses were compared. Methods: We organized children between the ages of six and fifteen into three groups by age, and distributed fifty-seven reverse geometry contact lenses, fifty-six MC lenses and seventy-eight single vision lenses among them to be worn. Group 1 consisted of children aged ten and under, Group 2 consisted of children between the ages of eleven and fifteen, and Group 3 represents all of the study participants. The aim of this study was to learn the inhibitive effects against myopia progression attained by changes of refractive correction value and to verify their statistical significance at twelve months and under, thirteen to twenty-four months and twenty-five to thirty-six months. Results: Changes of refractive correction value by each length of use in Group 3 were as follows. For the age group of under twelve months, participants using the reverse geometric contact lens showed no change, while those using the MC or single vision lens had significant changes (P<0.05) of $-0.36{\pm}0.10$ D and $-0.67{\pm}0.52$ D, respectively. Users of all three lens types displayed significant change (P<0.05), in the age group of between thirteen and twenty-four months, of $0.18{\pm}0.49$ D, $0.60{\pm}0.42$ D and $1.37{\pm}0.72$ D for users of the reverse geometry contact lens, the MC lens and the single vision lens, respectively. There were significant changes (P<0.05) of $0.29{\pm}0.61$ D, $0.93{\pm}0.57$ D and $1.72{\pm}0.78$ in the same respective order as the above in the age group of twenty-five to thirty-six months. Refractive correction value showed changes with different age group. Group 1 displayed significant changes (P<0.05) of $0.29{\pm}0.73$ D, $1.07{\pm}0.59$ D and $1.75{\pm}0.74$ D for users of the reverse geometry contact lens, MC lens and single vision lens, respectively, up to thirty-six months of lens wearing; Group 2, also up to thirty-six months, displayed significant changes (P<0.05) of $0.28{\pm}0.42$ D, $0.75{\pm}0.49$ D and $1.70{\pm}0.84$ D in the same respective order, and changes in refractive correction for the age group under ten years was significantly greater (P<0.05) for the age group of eleven and older. Conclusions: The results found in this study demonstrate that there were no changes of refractive correction value for the case of wearing reversing geometry contact lens up to twelve month or less. MC lens showed less changes in variations of visual acuity for all users which might be resulted in inhibiting progression of myoptia. When both reverse geometry contact lens and the MC lens are wearing for the period from 13 to 36 month, both lens showed less changes in variation of visual acuity for all users. The results suggested that the less changes in variation of visual acuity of both lens had an effect on inhibiting progression of myopia.

Model on the Contact Lens Movement from Eye-lid Blinking (순목 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.145-159
    • /
    • 2004
  • A mathematical model and its computer solution program were proposed to analyze the motion of contact lenses which are being subject to lid-blinking. The equation was derived by incorporating an acceleration induced lid's force exerting on the contact lens, the viscous damping resistance in the tear layer beneath the lens and the sliding frictional force between the lid and the contact lens surface into the formulation of differential equation describing the vibration. The model predicts the time-dependent displacement from the equilibrium postion during/after the blinking. During the blinking, as the time for the completion of one cycle of blinking decreases the off-the-equilibrium displacement of contact lens increases while the decrease of diameter in the contact cause the opposite effect. It is found that lid pressure exerting on the lens cause an insignificant lens displacement from the equilibrium position. After blinking the frequency of damped oscillation of contact lens decreases as the diameter of lens increases, due to the incresed surface while the reduced blinking time does not cause a significant frequency change. This is because that driving force for the contact lens movement posterior to blinking is the capillary-induced force not the lid force.

  • PDF

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.