• Title/Summary/Keyword: Contact Pressure Sensor

Search Result 94, Processing Time 0.029 seconds

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

Strength analysis of mechanical transmission using equivalent torque of plow tillage of an 82 kW-class tractor

  • Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Chung, Sun-Ok;Park, Seong-Un;Hong, Soon-Jung;Choi, Chang-Hyun;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.4
    • /
    • pp.723-735
    • /
    • 2019
  • The power-train is the most important component of an agricultural tractor. In this study, the strength of the driving gear transmission of an 82 kW-class tractor was analyzed using equivalent torque during plow tillage. The load measurement system consisted of an engine revolution speed sensor, torque-meters, revolution speed sensors for four axles, and pressure sensors for two hydraulic pumps. The load data were measured during plow tillage for four speed stages: F2 (2.78 km/h), F5 (5.35 km/h), F7 (7.98 km/h), and F8 (9.75 km/h). Aspects of the gear-strength such as bending stress, contact stress, and safety factors were analyzed under two torque conditions: the equivalent torque at the highest plow load for the F8 speed stage and the maximum engine torque. The simulation results using KISSsoft showed that the maximum engine torque conditions had a lower safety factor than did the highest equivalent torque condition. The bending safety factors were > 1 at all gear stages, indicating that gear breakage did not occur under actual measured operating conditions, nor under the maximum torque conditions. However, the equivalent torque condition in the contact stress safety factor was > 1, and the maximum torque condition was < 1 at the first gear pair. The method of analysis using the equivalent torque showed lower stress and higher safety factor than did the method using maximum torque. Therefore, when designing a tractor by applying actual working torque, equivalent torque method would support more reliable product development.

A Proposal of a New Model of Wheel and Tractor Dynamics that Includes Lift Resistance

  • Sakai, Jun;Choe, Jung-Seob;Kishimoto, Tadashi;Yoon, Yeo-Doo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1176-1185
    • /
    • 1993
  • The purpose of this study is to propose a new dynamic model of wheels and agricultural tractors through verification of the existence of " lift resistance " and "perpendicular adhesion" which also can be called " contra-retractive adhesion". The existence of these forces was proved through experiments including the development of a sensor which can measure the forces acting on a wheel accurately. Consequently " perpendicular adhesion ratio" which is defined as the ratio of the perpendicular adhesion to the distributed load was observed to be in the range of 0.05 to 0.3. This means the influence of the " lift resistance " is comparable to that of motion resistance in wheel dynamics. The perpendicular adhesion ratio was observed to decrease logarithmically with the increase of ground contact pressure, and to increase linearly with increase of the travel speed of the wheel . Some examples to express the new dynamic model compared to the conventional dynamics are explained.

  • PDF

Flexible Visuo-haptic Display (필름형 유연 시-촉각 융합 디스플레이)

  • Yun, Sungryul;Park, Suntak;Park, Bongje;Park, Seung Koo;Nam, Saekwang;Kyung, Ki-Uk;Prahlad, Harsha;von Guggenberg, Philip
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.3
    • /
    • pp.156-163
    • /
    • 2013
  • This paper describes a flexible visuo-haptic display module. We have developed a flexible electro-active polymer (EAP) actuator and a thin flexible visual display with $3{\times}3$ array configuration via polymer technology. The flexible actuator consists of nine EAP cells vertically moving in response to change in their thickness. The flexible display uses polymer based optical waveguide allowing light to scatter only at specific area. The display film is transparent and identically designed to the array pattern to fit for the arrangement of actuator cells. A pressure sensor is installed under the integrated module. The performance of the actuator is proved to be sufficient for satisfying perceivable range of human touch sense. The integrated system can provide interactive haptic feedback such as key pressing, contact vibration sensations, and etc. in accordance with user input.

An Experimental Study on Brake Judder of Braking on Vehicle (실차 상태에서의 제동시 이상떨림 현상에 관한 실험적 연구)

  • Hong, Il-Min;Lee, Won-Sub;Lee, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.5
    • /
    • pp.338-345
    • /
    • 2002
  • The study presents a new testing and analysis method for brake judder on vehicle. For the identification of the excitation mechanism of a brake judder, it is necessary to measure the dynamic brake disc geometry during braking on vehicle. The non-contact sensor system was used to monitor the brake disc geometry. Brake torque variation (BTV) caused by disc thickness variation (DTV) is the primary excitation for brake judder. The mechanical effects generating BTV are linked not only to initial manufacturing tolerances but also to uneven wear. Therefore, the brake disc geometry should be strictly managed to initial condition. The aim of this study has been to measure the dynamic DTV and runout on vehicle and analyze the influence of test parameters on brake judder and compare the disc component with vehicle matching about the DTV Profile. As a result of this study, The amplitude of brake judder is proportional to vehicle speed and fluid pressure fluctuation on braking. The major sources of brake judder are directly related to disc thickness variation and side runout variation of corner assembly (disc, hub. bearing).

Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes (테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구)

  • Lee, Jang-Ho;Kim, Hyeong-Dae;Kim, Jung-Bae;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

Fabrication and Characteristics of Photoconductive Amorphous Silicon Film for Facsimile (팩시밀리용 비정질 실리콘 광도전막의 제작 및 특성)

  • Kim, Jeong-Seob;Oh, Sang-Kwang;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • Contact-type linear image sensors for facsimile have been fabricated by means of rf glow discharge decomposition method of silane. The dependence of their electrical and optical properties on rf power, $SiH_4$ flow rate, ambient gas pressure, $H_2SiH_4$ ratio and substrate temperature are described. The a-Si:H monolayer demonstriated photosensitivity of 0.85 and $I_{ph}/I_d$ ratio of 100 unger 100 lux illumination. However, this monolayer has relatively high dark current due to carrier injection from both electrodes, resulting in low $I_{ph}/I_{dd}$ ratio. To suppress the dark current we have fabricated $SiO_2/i-a-Si:H/p-a-Si:H:B$ multilayer film with blocking structure. The photocurrent of this multilayer sensor with 6 V bias became saturated ar about 20nA under 10 lux illumination, while the dark current was less than 0.2 nA. Moreover, the spectral sensitivity of the multilayer film was enhanced for short wavelength visible region, compared with that of the a-Si:H monolayer. These results show that the fabricated photocon-ductive film can be used as the linear image sensor of the facsimile.

  • PDF

The quantitative study on the Renying·Qi mouth comparison pulse diagnosis (인영(人迎)·기구비교맥법(氣口比較脈法)의 정량화(定量化)에 관(關)한 연구(硏究))

  • Cho, Myung-Rae;Kim, Moo-Shin;Ryu, Choong-Ryul;Choi, Chan-Hun;Jang, Kyeong-Seon;So, Cheol-Ho;Park, Young-Dae
    • Journal of Acupuncture Research
    • /
    • v.19 no.2
    • /
    • pp.149-163
    • /
    • 2002
  • Objective : We have studied literatures of Renying Qi mouth comparison pulse diagnosis theory and distinguished the excess, deficiency and quick-temper of pulse as the measurement parameter of Renying Qi mouth pulse diagnosis. Methods : We have acquired pulse signals of Renying Qi mouth by using diagnostic equipment of Renying Qi mouth pulsation and estimated reappearance of pulse signals. Results : 1. The measurement parameter of Renying Qi mouth pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Renying Qi mouth. 2. When we acquired the pulse singals of Renying Qi mouth by using diagnostic equipment, the property, measuring area, bias pressure, contact or adhesion state of the sensor are considered. 3. As getting the pulse signal of Renying Qi mouth, the sensor of a sound detective mode is effective. 4. The diagnostic equipment of Renying Qi mouth pulse is assessed as being significant reappearance.

  • PDF

Development of Smart Air Car Seat Control System for Automatic Air Conditioning using IoT Sensor (IoT 센서를 이용한 공기 자동조절 스마트 에어카시트 제어 시스템 개발)

  • Kim, Dae-Hun;Jeong, Sueun;Park, Suhyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.208-210
    • /
    • 2021
  • As the number of objects connected to the Internet increases rapidly, intelligent device development projects are gradually expanding that provide direct value to humans, away from simple monitoring functions, including sensors and communication functions, or delivery to servers.It is expected that the device will develop a technology that analyzes surrounding sensing information and changes the surrounding environment in consideration of users' preferences or safety. By establishing a biosignal measurement system in a developed product that can bring various effects using air, it will be possible to grasp the user's condition through a pattern of change in pressure distribution when seated. This paper proposes a construction system that enhances the comfort of using an air car seat through contact between a temperature measurement sensor and a user, and enables effective management of measured biosignals by linking them with an air pump control system.

  • PDF

Clinical Study on the Floating and Sinking Pulse Detection with Piezoresistive Sensors and Contact Pressure Control Robot (압저항 센서와 가압조절 로봇을 이용한 부침맥 검출에 관한 임상연구)

  • Lee Si-Woo;Lee Yu-Jung;Lee Hae-Jung;Kang Hee-Jung;Kim Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1673-1675
    • /
    • 2005
  • The pulse diagnosis is an important and universal method in Oriental medicine. Nevertheless, because of characteristic that depends on subjective sense of Oriental medicine doctor (OMD), it is not recognized by objective basis. The Korean Institute of Oriental Medicine(KIOM) and Daeyo Medi. Co. Ltd. developed the 3-D Mac using arrey piezoresistive sensors and multi-axial robot. 133 healthy subjects participated in this study, 75 males and 58 females, between 20 and 70 years of age. All subjects were relaxed in a supine position on a comfortable chair for twenty minutes before the measurement was taken. The measured position is the radial artery of subject's left wrist and the position is called Chon, Kwan and Chuck in Oriental medicine. To detect floating and sinking pulse, we established coefficient of floating and sinking(CFS). CFS means relative position of maximum pulse pressure in PH curve. The lower CFS value means that the pulse has floating tendency. There was significant diffence between CFS and diagnosis of floating-sinking pulse by OMD(p=0.020). CFS value of over 40's group was significantly larger than those of 20's and 30's(p=0.000). There was no significant difference between male and female(p=0.061).