• Title/Summary/Keyword: Contact Patch

Search Result 95, Processing Time 0.025 seconds

CONTACT PRESSURE DISTRIBUTION OF RADIAL TIRE IN MOTION WITH CAMBER ANGLE

  • Kim, Seok-Nam;Kondo, Kyohei;Akasaka, Takashi
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.387-394
    • /
    • 2000
  • Theoretical and experimental study is conducted on the contact pressure distribution of a radial tire in motion under various camber angles. Tire construction is modelled by a spring bedded elastic ring, consisted of sidewall springs and a composite belt ring. The contact area is assumed to be a trapezoidal shape varying with camber angles and weighted load. The basic equation in a quasi-static form is derived for the deformation of a running belt with a constant velocity by the aid of Lagrange-Euler transformation. Galerkin's method and stepwise calculation are applied for solving the basic equation and the mechanical boundary condition along both sides of the contact belt part subjected to shearing forces transmitted from the sidewall spring. Experimental results on the contact pressure, measured by pressure sensors embedded in the surface of the drum tester, correspond well with the calculated ones for the test tire under various camber angles, running velocities and weighted loads. These results indicate that a buckling phenomenon of the contact belt in the widthwise direction occurs due to the effect of camber angle.

  • PDF

Non-contact Longitudinal Modal Testing of a Non-ferromagnetic Pipe Using Magnetostrictive Patches (자기 변형 패치를 이용한 비자성 배관의 비접촉 종진동 모달 테스팅)

  • Park, Chan-Il;Han, Soon-Woo;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.293-298
    • /
    • 2008
  • Non-contact modal testing for longitudinal modes of a pipe is discussed in this work. The suggested method can generate and measure longitudinal vibrations without mechanical contact by using the coupling phenomenon between deformation and magnetic field, known as the magnetostrictive effect. This effect has been used to generate and measure ultrasonic waves, but seldom used to deal with audible vibrations. In this investigation, the validity of the developed method in a typical vibration frequency range is checked with an Inconel pipe being used in nuclear power plants.

Experiments and Prediction of Pitting Life in Spur Gears (스퍼기어의 피팅 수명 예측 및 실험)

  • Kim, Jong-Sung;Ju, Jin-Wook;Lee, Sang-Don;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.399-403
    • /
    • 2009
  • The objective of this paper is to predict pitting initiation by using a contact analysis and subsurface stress. Contact stresses are obtained by contact analysis of a semi-infinite solid based on the use of influence functions. Subsurface stress field is obtained using rectangular patch solutions. It is used Mesoscopic multiaxial fatigue criterion to predict contact fatigue life. It is important to predict pitting initiation to enhance reliability of the mechanical elements. Pitting life prediction in the spur gears which are fundamental mechanical element is presented in this paper.

Contact treatment algorithm of z-map model with vertical walls and its application to the deep drawing of a clover shaped cup (Z-map으로 표현된 수직 벽면을 가진 금형에서의 접촉처리법과 클로버형 컵 디프드로잉 공정의 해석에의 응용)

  • 서의권;박정환;심현보
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.5
    • /
    • pp.38-45
    • /
    • 1998
  • The Z-map model which is quite similar to the non-parametric patch is widely used to describe the shape of a surface because of its simplicity. Despite the inherent advantage of z-map model. it has drawbacks that there exists difficulty in expressing the vertical walls and its related contact treatment method. In the region of vertical walls, there is a convergence problem in searching the contact point. In this study a contact point finding scheme is presented, based on the z value of the z-map model on the sheet normal direction. To show the utility of this scheme a compared with the experimental results. The effects of the Z-map grid distances and the interpolations of the inside Z-map value are also discussed.

  • PDF

Non-contact Longitudinal Modal Testing of a Non-ferromagnetic Pipe Using Magnetostrictive Patches (자기 변형 패치를 이용한 비자성 배관의 비접촉 종진동 모달 테스팅)

  • Park, Chan-Il;Han, Soon-Woo;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1343-1347
    • /
    • 2006
  • Non-contact modal testing for longitudinal modes of a pipe is discussed in this work. The suggested method can generate and measure longitudinal vibrations without mechanical contact by using the coupling phenomenon between deformation and magnetic field, known as the magnetostrictive effect. This effect has been used to generate and measure ultrasonic waves, but seldom used to deal with audible vibrations. In this investigation, the validity of the developed method in a typical vibration frequency range is checked with an inconel pipe being used in nuclear power plants.

  • PDF

A Study on Ultra-Wideband Patch Antenna with Modified Barrel Shape (변형된 항아리형 초 광대역 패치안테나의 설계에 관한 연구)

  • Kim, Sun-Hyo;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.263-270
    • /
    • 2016
  • This paper implemented an ultra-wideband(: UWB) antenna by using a modified barrel-shaped patch antenna. The designed UWB patch antenna was optimized to match UWB technical specifications by considering the sizes of barrel circle and oval(notch) which is distance between the patch and contact surface and designed antenna was implemented by $10mm(R1){\times}21.8mm$ size. Optimal values on the basis of simulated reflective loss results, the surface current distribution of designed patch antenna was analyzed in order to check operation mode of antenna and wideband mechanism. Experimental results of implemented UWB antenna, Return loss of UWB antenna the voltage standing wave ratio was 2 or less in the 1.775-13.075 GHz band, VSWR in 2 or less. And the maximum gain of approx. 1-3 dBi was found in 3.1-10.6 GHz. This result satisfied the characteristics of ultra-wideband and the proposed antenna will be applicable to an ultra-wideband system.

A Study on the dynamic behavior of rail due to dipped joints (레일이음매의 동적거동에 대한 연구)

  • Kang, Yun-Suk;Yang, Shin-Chu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.328-333
    • /
    • 2002
  • When vehicle travelling along the track which has irregularity such as vertical profile, dynamic forces arise at the Wheel/Rail contact patch by wheel/rail interaction. In particular short wavelength irregularities on dipped joint and small stiffness of connecting rail bring about intense wheel/rail dynamic effects at higher speed. In the paper, a new model for dipped joint rail is developed to study dynamic behavior of track. A cusp behavior on dipped joint was defined by its amplitude and decay factor, which was presented by FRA track classes. The result of case study are presented, which show wheel rail contact force in each track classes, train operation speed and bending flexible rigidity ratio of fishplates which are connecting the rail.

  • PDF

Sub-surface Stress Analysis beneath the Contact Surface of Spur Gear Teeth (스퍼 기어 접촉 치면의 내부응력 해석)

  • Kwang-Jin, Lee;Hyung-Ja, Kim
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.3
    • /
    • pp.64-70
    • /
    • 2004
  • The sub-surface stress field beneath the spur gear's contact surface in lubricated condition has been analysed. The surface pressure was obtained by the elasto-hydrodynamic lubrication analysis using the accurate geometric clearances around the contact region of the teeth. The sub-surface stress field was calculated by using the Love's rectangular patch solution. The analysis results show that the sub-surface stress distribution is quite dependent on the surface pressure distribution. The pattern of sub-surface stress field is similar to that of the external load. The depth where the maximum effective stress occurs is not proportional to the intensity of the external load.

  • PDF

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Evaluation of Hypersensitivity Reaction to Dental Materials with a Patch Test (첩포시험을 이용한 치과용 재료의 알러지 평가)

  • Jeon, Hee-Sun;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.167-172
    • /
    • 2000
  • Both immune reaction and hypersensitivity reaction are occurred by the same mechanism, the antigen and antibody reaction. The favorable result of this reaction towards a host is called clinically an immune reaction and the opposite results is called an hypersensitivity reaction. Type IV hypersensitivity reaction is a delayed type which is related to the cellular immune reaction and a contact hypersensitivity is included in this type. Various dental materials such as metal (mercury, nickel, chrome, cobalt), resin and eugenol are etiologic substances. Patch test kit is composed of test substance with a controlled concentration which respond only to a susceptible patient and an aluminum chamber, and etiologic substances for hypersensitivity can be easily and comfortably found just by applying the kit to the patient's skin. In this case report, the patch test was performed to a patients with oral lichen planus and the allergen, restorative material was found. After removal of the matching restoration from the patient's mouth, the symptom was improved.

  • PDF