This paper presents a new graphical method for selecting a pair of optical glasses to simultaneously achromatize and athermalize an imaging lens made of materials in contact. An athermal glass map that plots thermal glass constant versus inverse Abbe number is derived through analysis of optical glasses and plastic materials in visible light. By introducing the equivalent Abbe number and equivalent thermal glass constant, although it is a multi-lens system, we have a simple way to visually identify possible optical materials. Applying this method to design a phone camera lens equipped with quarter inch image sensor having 8-mega pixels, the thermal defocuses over $-20^{\circ}C$ to $+60^{\circ}C$ are reduced to be much less than the depth of focus of the system.
Quaternary ammonium compounds(QACs) are some of the most commonly used antimicrobials. Antimicrobial polymers have been used as biomedical devices. In this Study, We synthesized new methacrylate monomers including quaternary ammonium moieties for preparation of contact lens, And also, we tested for antimicrobial activities against S. aureus, E. coli and P. aeruginosa. They showed much higher antimicrobial activities against all than the polymers of no including quaternary ammonium.
Poly(hydroxyethyl methacrylate)-based hydrogels were surface-functionalized with spiropyran (SP) derivatives to obtain photochromic contact lenses. The contact lens reversibly changes from colorless to purple as response to UV light since colorless ring-closed SP state converts to purple ring-opened merocyanine (MC) state under UV light irradiation. The purple contact lens emits red light at 640 nm. Importantly, the presence of SP segments did not significantly affect the equilibrium water content (EWC) of the lens. SP-functionalized hydrogel lenses may find potential applications in developing light-adaptive ophthalmic materials.
콘택트렌즈는 시력 보정의 목적으로 개발되기 시작하여 최근에는 다양한 목적을 위해 이용되고 있다. 특히, 콘택트렌즈를 IT, NT, BT와 융합하여 질병 진단을 목적으로 이용하는데 관심이 높아지고 있다. 본지에서는 콘택트렌즈의 재료와 최근 주목받고 있는 진단용 콘택트렌즈와 소재에 대해 소개하고 앞으로 전망에 대해 논하였다.
Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
Journal of Korean Ophthalmic Optics Society
/
v.19
no.2
/
pp.153-162
/
2014
Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.
Purpose: The surfaces and compositions of rigid gas permeable (RGP) contact lenses were analyzed with the consistent methods, and the basic informations for the composition design of lens materials were suggested. Methods: The bulk structures were analyzed by using Fourier infrared spectroscopy (FTIR), the compositions of surface components were observed by using x-ray photoelectron spectroscopy (XPS), the surface morphology and roughness were observed using atomic force microscopy (AFM), and the wettabilities were estimated by the surface wetting angles. The relations and trends of those results were analyzed. Results: The high oxygen permeability RGP lenses showed the trend that the fluorine decreases and the silicon increases. As the silicon and fluorine contents increased, the carbon and oxygen contents of RGP lens materials decreased at a constant ratio. The decreasing ratio of the carbon contents was three times larger than the decreasing ratio of oxygen contents. The composition of the surface treated lens was far from these tendency line. When the silicon contents increased, the rough surface was formed with the cohered particles. When the fluorine contents increased, the rough surface was formed with the deep flaws. The surface roughness increased and then wettabilities decreased as the silicon and fluorine contents increased. For the surface roughness changes, the increasing ratio of the silicon contents was two times larger than the increasing ratio of fluorine contents. The surface of RGP lens materials appeared the hydrophobic character of which the wettabilities decreased when the roughnesses increased. Conclusions: The surfaces and compositions of RGP contact lenses were measured by the same methods. Those results and relationships were compared and analysed. It is considered that these research results will be applied with the basic data for the composition design of lens materials.
Kim, Bong-Hwan;Han, Seon-Hee;Kim, Dae-Hyeon;Byeon, Sang-Hyeon;Chae, Jeong-Im;Kim, Jae-Seok;Hwang, Yun-Jeong;Kim, Hak-Jun
Journal of Korean Clinical Health Science
/
v.3
no.3
/
pp.378-389
/
2015
Purpose. The actual status of wearing toric soft contact lenses was investigated to learn why it is not used although it is required. Materials and Methods. This study has studied 64 contact lens wearing the local college students, Gyeongsangnam-do who are 20.17(${\pm}0.70$)years old, by measuring their refractive power and over-refractive power with auto refractometer(HRK-8000A, Huvitz, Korea). In addition to that, a survey was done to figure out why they do not wear toric soft contact lenses, the purpose of using toric soft contact lenses, whether they have astigmatism or any knowledge about it, the kinds of contact lens, whether they are willing to buy corrective lenses, and how they are satisfied after purchasing them. Results. 17 students (21.9%) said they experienced light-spread; 9 students (14.1%)said that they have dizziness when they wear contact lens all day long. In the survey to see whether they had astigmatism or not, 37 students (57.8%) said they had it. For the reason they do not wear toric soft contact lenses, 33 students (51.6%) said that "they were prescribed regardless of astigmatism in the optometrist." To the question asking if they are willing to buy toric soft contact lenses according to the existence of astigmatism, 51 students (79.6%) answered they are. 31 students (48.4%) said they heard a description about astigmatism at the time of purchase for contact lens. Conclusion. As the ways for any people who need to correct astigmatism to wear corrective lens, enough education about astigmatism and consistent follow-up management are needed, where the role of optometrist is considered important.
The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.
Park, Mijung;Shin, Young Min;Chang, Ji Yeon;Kim, Daesoo
Journal of Korean Ophthalmic Optics Society
/
v.10
no.2
/
pp.91-97
/
2005
We investigated the question whether protein removing activities of enzyme cleaner - protein remover for soft contact lens - are associated with the material of soft contact lens as well as action time, temperature and pH of enzyme solution. We used a subtilisin cleaner as protein remover and estimated the protein amount remained on soft contact lens after using the subtilisin cleaner under the different conditions. The remained protein in soft contact lens was greatly decreased until treatment for 60min, but no significant differences were found from 60min to 24hr. The cleaning effect of the enzymatic treatment in the range of $15{\sim}30^{\circ}C$ was constant. however, there was a significant decline of the protein removing effect at $10^{\circ}C$ and less. The pH of the solution was also important for the efficacy of the enzymatic treatment. The activity of the enzyme cleaner was highest in pH 8.0 and significantly decreased a pH below 7. The pH dependence was found to be related to the conformational change of subtilisin. Furthermore, significant differences in the protein deposit removing efficacy of the subtilisin cleaner were found among the soft contact lens materials.
Kim, Ockchul;Park, HyungDal;Song, Young-won;Kim, Jinseok
Journal of Biomedical Engineering Research
/
v.37
no.5
/
pp.178-185
/
2016
Tear is a promising biological fluid for non-invasive health monitoring. It has been studied in the past to be a possible candidate for the diagnosis of certain systemic diseases, such as breast cancer, multiple sclerosis, prostate cancer, and diabetes. However, currently existing methods for collecting and extracting tear from the human eye causes inconsistencies in the biomolecule concentrations of the tear sample due to the irritating nature of the process. In response, we designed and fabricated a microfluidic system embedded soft contact-lens for the purpose of tear sampling. The lens was then tested with artificial tear for its tear sampling capability, and found to be able to find concentration equilibrium within 50 minutes. Additionally, simulation was carried out to further optimize the design so that tear sampling rate matched the natural tear turn-over rate of 1 microliter per minute.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.