• Title/Summary/Keyword: Contact Lens Materials

Search Result 64, Processing Time 0.022 seconds

Study on the Silicone Contact Lens Using AA and BMA (AA(Acrylic acid)와 BMA(Butyl methacrylate)를 이용한 실리콘 콘택트렌즈에 관한 연구)

  • Kim, Tae-Hun;Yae, Ki-Hun;Kweon, Young-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.259-265
    • /
    • 2006
  • We polymerized material of AA(Acrylic acid) and BMA(butyl methacrylate) to make up for the weak points of hydrogel contact lens. The synthesis process of silicone synthesis is as follows. Acrylate-PDMS(Polydimethylsiloxane)-Urethane prepolymer was composed after Diisocynate reacted with HEMA(2-hydroxyethylmethacrylate) under the catalyst and it reacted again with bis(hydroxyalkyl) terminated poly(dimethylsiloxane) with high oxygen transmissibility characteristics. HEMA(2-hydroxyethylmethacrylate) was used to make prepolymer that can be polymerized and the urethane was used to improve elasticity and oxygen transmissibility, copolymerization was performed with conventional hydrogel contact lens materials to make silicone hydrogel contact lens with higher oxygen transmissibility. For manufacturing of contact lens, We added BMA(Butyl methacrylate) with better elasticity and flexibility, and AA(Acrylic acid) with higher moisturizing to used contact lens materials. AIBN (Azobis2-methylpropionitrile) as initiator and EGDMA(Ethylene Glycol Dimethacrylat) as crosslinking agent were used and the lens with higher oxygen transmissibility and better moisturizing were manufactured complying with basic contact lens properties, which have several combination trial of each monomer characteristics. Compounding SN which included SILICONE, HEMA, NVP and EGDMA etc was showed by swelling ratio of 9.38% and water content of 23.7%. SN was showed by swelling ratio of 9.38%, water content of 23.7% and a visible ray transmissibility of 89%. SB which added BMA in the SN was showed by swelling ratio of 12.50%, water content of 18.56% and a visible ray transmissibility of 88%. SAB which added both AA and BMA in the SN was showed by swelling ratio of 8.33%, water content of 12.93% and a visible ray transmissibility of 88%.

  • PDF

Synthesis of Polymer Materials Containing Platinum Nanoparticles and Their Application for Contact Lenses (백금 나노입자를 포함한 고분자재료의 합성 및 콘택트렌즈로의 응용)

  • Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • Platinum nanoparticles were added to a mixture of HEMA (2-hydroxyethyl methacrylate), NVP (N-vinyl pyrrolidone) and MMA (methyl methacrylate) in a mould at various concentrations. The resulting mixture was copolymerized by heating at $70^{\circ}C$ for 40 min, $80^{\circ}C$ for 40 min, and $100^{\circ}C$ for 40 min, respectively. The physical properties of contact lens were then measured. The oxygen transmissibility of $9{\sim}15{\times}10^{-9}$ cm/s mL $O_2$/mL ${\times}$ mmHg, water content of 34.22~35.52%, refractive index of 1.432~1.435, visible transmittance of 88.3~91.2% and tensile strength of 0.141~0.152 kgf were obtained. The addition of platinum nanoparticles to the polymer allowed the contact lens to have various colors without artificial coloring agents. The polymer materials satisfied the physical properties required to produce contact lenses, making the material suitable to be applied as a functional material for ophthalmological purposes.

Effectiveness of Overnight Orthokeratology with a New Contact Lens Design in Moderate to High Myopia with Astigmatism

  • Park, Yuli;Kim, Hoon;Kang, Jae Ku;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.229-237
    • /
    • 2021
  • Background and Objectives To assess the effectiveness of overnight orthokeratology (OK) in myopia using a new contact lens design over a one-month wearing period. Materials and Methods Participants were required to have myopia between -3.00 and -7.50D and astigmatism ≤ 2.00 D to participate in the study. The participants underwent OK with the White OK lens® (Interojo, Pyungtek, Korea), which has a 6-curve lens design. Participants were assessed at weeks 1, 2, and 4 using slit-lamp bio-microscopy, and tested for refraction, uncorrected distance visual acuity, and corneal topography. Success was defined as achieving a Logarithm of the Minimum Angle of Resolution (logMAR) ≤ 0.1. Results A total of 46 eligible subjects with a mean age of 23.11 ± 7.89 years were recruited. Baseline logMAR was 1.18 ± 0.30 and a consistent decrease in logMAR was observed from week 1 to week 4. The success rate was 95.35% at week 4. The mean sphere significantly decreased from a mean pre-fitting value of -4.58 ± 1.28 D to a mean value of -0.65 ± 0.69 D at week 4 (p < 0.0001). Statistically significant corneal flattening was detected during keratometry at week 4. Conclusion Overnight OK with the White OK lens is effective for the correction of moderate and high myopia with astigmatism over a one-month wearing period.

Characterization of Hydrogel Tinted Contact Lens Containing 4-iodoaniline using Titanium Silicon Oxide Nanoparticles as Additive (티타늄 실리콘 옥사이드 나노입자를 첨가제로 사용한 4-iodoaniline을 포함한 하이드로젤 착색 콘택트렌즈의 특성)

  • Cho, Seon-Ahr;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.315-322
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic tinted contact lens containing titanium silicon oxide nanoparticles and the basic hydrogel contact lens material containing 4-iodoaniline were examined. In this study, the utility of titanium silicon oxide nanoparticles as a UV-blocking material for ophthalmologic devices were investigated by measuring the UV transmittance of the produced polymer. Also, titanium silicon oxide nanoparticles only without the addition of 4-iodoaniline in primary contact lens materials by copolymerizing two groups were compared. Methods: For manufacturing hydrogel lens, HEMA, MA, MMA, 4-iodoaniline and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. Also, the titanium silicon oxide nanoparticles was used as additive. After polymerization the physical properties such as water content, refractive index, contact angle and spectral transmittance of produced contact lenses were measured. Results: Measurement of the physical properties of the copolymerized material showed that the water content, refractive index, UV-B transmittance and contact angle were in the range of 35.01~38.60%, 1.4350~1.4418, $34.15{\sim}57.25^{\circ}$ and 1.0~10.0%, respectively. Titanium silicon oxide nanoparticles is not used as an additive in the experimental group, the results of the measurement showed that the water content, refractive index, contan angle and UV-B transmittance of the hydrogel lens polymer was 34.00~36.80%, 1.4378~1.4420, $40.15{\sim}60.16^{\circ}$ and 1.8~25.0%, respectively. Conclusions: Also, the transmittance for UV light was reduced significantly in combinations containing titanium oxide nanoparticles.

Tool Mark Removal Method of Aspherical Glass tens Mold by Reverse-rotational Eccentric Motion (역회전 편심 운동 방식에 의한 비구면 유리렌즈 금형의 공구마크 제거 방법에 관한 연구)

  • Lee, H.C.;Kim, J.U.;Kang, H.H.;Kim, D.S.
    • Transactions of Materials Processing
    • /
    • v.18 no.2
    • /
    • pp.172-176
    • /
    • 2009
  • In this paper, new aspherical surface polishing mechanism is suggested to polish aspherical glass lens mold by both airbag polishing tool and reverse-rotational eccentric motion. Up to now, conventional aspherical lens polishing method by the small tool polishing uses the aspherical surface profile and the trajectory of the polishing tool is also controlled. However, full contact concept by airbag polishing tool and no position control make the easy polishing setup and does not need aspherical design profile. An aspherical lens polishing machine was made for this study and a tool mark removal experiment fur the fine-grounded lens mold was successfully performed.

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

The Change in Refractive Powers of Soft Contact Lenses Caused by the Deposition of Tear Proteins (누액 단백질 침착에 의한 소프트콘택트렌즈의 굴절력 변화)

  • Choi, Jin-Yong;Park, Jae-Sung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether refractive powers of soft contact lenses were induced by the deposition of tear proteins when wearing soft contact lenses. Methods: The soft contact lenses (material: etafilcon A, hilafilcon A and comfilcon A) with refractive powers of -1.00 D, -3.00 D, -5.00 D and -7.00 D were incubated in artificial tear for 1 day, 3 days, 5 days, 7 days and 14 days, respectively. After incubation, their refractive powers were measured by wet cell method with an auto-lens meter and their protein deposited on the lenses was determined by the method of Lowry. Results: Among three types of soft contact lenses, the most protein deposition was detected in ionic etafilcon A lens material and significant change of its refractive power was manifested. In other words, refractive powers of etafilcon A lenses firstly decreased after 1 day incubation in artificial tear and then gradually increased with increasing incubation period again. The observed change in refractive powers of all diopters of etafilcon A material was beyond the scope of standard error and bigger in the lens with lower optical power. On the other hand, non-ionic hilafilcon A showed less protein deposition as much as about 20% in etafilacon A and statistically significant increase of refractive powers with increasing incubation period in artificial tear. The change in refractive power of hilafilcon A was also beyond the scope of the standard of error when incubating in artificial tear and greater in the lens with lower diopter. The least protein deposit was shown in silicone hydrogel lens material, comfilcon A as approximately 10% of it in etafilcon A, indicating less change in refractive power within the standard range of error. Conclusions: The large change of refractive powers that was beyond the scope of standard error by the deposition of tear proteins on soft contact lenses was differently detected depending on lens materials in the current study. Thus, the deposition of tear proteins induced by longer period of lens wearing may be one of the causes that induces blurred vision, suggesting that soft contact lens wearers with the amount of tear proteins may need to choose proper lens material.

The Change of Blink Rate by Wearing Soft Contact Lens (소프트콘택트렌즈 착용에 의한 순목 횟수 변화)

  • Lee, Youn-Jin;Park, Sang-Il;Lee, Heum-Sook;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.173-179
    • /
    • 2006
  • We investigated the change of the blink rate by wearing soft contact lens(SCL). Eight types of soft contact lenses were worn by twelve asymptomatic contact lens wearers. When wearers were worn SCLs for 15 min, the average blink rate was 20.0 blinks/min, which was a statistically significant increase compared to 13.3 blinks/min, the average blink rate of non-SCL-worn eye. After 8 hr of lens wear, the average blink rate was 24.3 blinks/min, and it was 11 blinks/min more than that of non-SCL-worn eye and 4 blinks/min more than that of 15 min SCL-worn eye. There were a little difference of the blink rate in types of lens, which the blink rate range of all lens after 15 min of lens wear was 18.1~20.9 blinks/min and that after 8 hr of lens wear was 22.9~24.9 blinks/min. When wearing A lens(vifilcon, 0.06 mm) having thin center thickness, wearers showing difference of 10.0~11.9 blinks/min between non-SCL-worn eye and 15 min SCL-worn eye reached 16.7% and it was more than that of relatively thick B lens(0.17 mm) and C lens(0.14 mm). This result suggest that the center thickness was not unique factor of the blink rate change and other factors would have synthetically influence on the blink rate change. In the case of B lens and C lens of hilafilcon material but having different center thickness and water content, wearers increasing more than 4.0 blinks/min after 8 hr of lens wear was 58.3% and 41.7%, respectively. This result have provided information that the lenses of similar materials but different center thickness and water content could cause individually the different change of the blink rate.

  • PDF

Influence of Wetting Agents on Physical Properties of Soft Contact Lens (친수성 소프트 콘택트렌즈의 물리적 특성에 미치는 습윤성 재료의 영향)

  • Lee, Min-Jae;Sung, A-Young;Kim, Tae-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic contact lens polymerized with addition of glycerin and PVP(polyvinylpyrrolidone) in the basic hydrogel contact lens material were evaluated. Methods: This study used glycerin and PVP(polyvinylpyrrolidone) with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Results: Measurements of the physical characteristics of the copolymerized material including PVP(polyvinylpyrrolidone) showed the refractive index of 1.4382~1.4288, tensile strength of 0.3446~2542 kgf and water content and contact angle of sample showed the increase of 13.49% and decrease of 21.44% independently. And also, the physical characteristics of the copolymerized material including glycerin showed the refractive index of 1.4330~1.4328, tensile strength of 0.2974~0.2854 kgf, water content 35.58~36.53% and contact angle of sample showed the decrease of 37.64%. Conclusions: Based on the results of this study, the produced copolymers is suitable for conventional lens with high wettability. Also, glycerin minimized the changes of water content and refractive index at the same time, increased the wettability of the hydrogel lens materials.

Preparation and Analysis of Functional Hydrogel Lenses Using Cerium Iron Hydroxide Nanoparticles

  • Shin, Su-Mi;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.13 no.1
    • /
    • pp.13-18
    • /
    • 2020
  • This study used cerium iron hydroxide nanoparticle with HEMA (2-hydroxyethyl methacrylate), the cross-linker EGDMA (ethylene glycol dimethacrylate), NVP (N-vinyl-2-pyrrolidone) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Also, the physical properties of the prepared lenses were compared, and their applicability as polymers for ophthalmic materials was experimented. The results of the measurement showed that the UV blocking rate and the wettability increased with the cerium iron hydroxide nanoparticles addition ratio, and the refractive index and water content were not affected. Thus, the produced copolymer is expected to be useful as a functional contact lens material while satisfying the basic physical properties of the hydrogel contact lens.