• 제목/요약/키워드: Contact Frequency

검색결과 1,044건 처리시간 0.026초

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

$ITO/Alq_3/Al$ 소자의 주파수 의존 응답을 이용한 유기 발광소자의 등가회 로 분석 (Equivalent-Circuit Analysis of Organic Light-Emitting Diodes using Frequency-dependent Response of $ITO/Alq_3/Al$ Device)

  • 안준호;정동회;허성우;이준웅;송민종;이원재;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 제6회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.5-8
    • /
    • 2004
  • We have investigated equivalent-circuit analysis of organic light-emitting diodes using frequency-dependent response of $ITO/Alq_3(60nm)/Al$ device at two different bias voltages. Complex impedance Z of the device was measured in the frequency range of 40Hz~1MHz. A Cole-Cole plot shows that there are two dielectric relaxations at the bias below turn-on voltage, and one relaxation at the bias above turn-on voltage. We are able to interpret the frequency-dependent response in terms of equivalent-circuit model of contact resistance $R_s$ in series with parallel combination of resistance $R_p$ and capacitance $C_p$. We have obtained contact resistance $R_s$ around $90{\Omega}$, mainly from the ITO anode.

  • PDF

VIM에 의해 제조된 고주파 유도경화 베어링강의 특성에 관한 연구 (Characteristics of High Frequency Induction-Hardened Bearing Steel Produced by VIM)

  • 최병영;장정석
    • 한국재료학회지
    • /
    • 제8권12호
    • /
    • pp.1176-1181
    • /
    • 1998
  • VIM에 의해 제조된 0.55wt.% C-1.68wt.% Mn강을 사용하여 고주파 유도경화 베어링강의 특성을 조사하였다. 시편의 청정도는 DIN 50602에 의한 K4값이 6.41로 측정되어 높게 나타났다. 고주파 유도경화된 시편은 약 2.7mm의 유효경화층 깊이를 가진 표면경화층이 형성되었으며 불균질한 submicron크기의 lath 마르텐사이트가 표면경화층에 형성되었다. 회전접촉 피로 시험은 최대 헤르쯔 응력 492 kgmm$^{-2}$ 을 가하며 탄성유체 윤활조건에서 실시되었다. 회전접촉 피로시험 후 시편의 궤도면 직하에서 측정된 미소경도는 유도경화한 경우에 비해 표면직하 약 $500\mu\textrm{m}$ 깊이까지 증가하였다. 그 경도증가량의 최대치를 나타내는 위치는 표면에서부터 약 100$\mu\textrm{m}$ 깊이로 밝혀졌으며 백색부식영역 (white etching area)을 나타내었다 회전접촉 피로시험 후 시편의 궤도면 직하, 이 백색 부식영역에서 균열이 생성되고 전파하였다.

  • PDF

중환자실 간호사의 간호행위 전.후 손씻기 수행율 비교 (Rates for Handwashing Adherence Before and After Nursing Contact in Intensive Care Units)

  • 김영중;김희승;장윤영
    • 기본간호학회지
    • /
    • 제18권2호
    • /
    • pp.195-200
    • /
    • 2011
  • Purpose: The purpose of this study was to assess rates for handwashing adherence before and after nursing contact in intensive care units (ICU). Methods: The participants included 90 nurses working in intensive care units of an 800-bed university-affiliated hospital in Gyeonggi Province and 2000-bed university-affiliated hospital in Seoul. Time for handwashing was calculated using the average number of handwashings during an 8-hour day shift. Nursing contact was based on indications as defined by the Centers for Disease Control and Prevention (CDC, 2002). Data were analyzed using frequency, percent, t-test and ${\chi}^2$-test. Results: During an 8-hour day shift, the average number of times that hands were washed was 25.0. The rates were significantly lower before the nursing contact than after the nursing contact when it involved sectioning, observation or contact with a wound, cleaning enteric feeding bag, physical exam, use of gloves, or contact with contaminants. Conclusions: The results indicate that as handwashing rates were significantly lower before nursing contacts than after nursing contacts, there is need to develop strategies to address this deficiency in handwashing.

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

원자력발전소 게이트밸브의 스템 - 벨로우즈 접촉면에 관한 연구 (A Study on the contact surface of Stem and Bellows of Gate Valve in Nuclear Power Plants)

  • 고석훈;심동혁;김대열;최명진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1044-1048
    • /
    • 2006
  • Nuclear power generation is very dangerous in occasion that skirt of structure by earthquake although it is high effective generation that can make a lot of energies with few raw material. when design, it must consider a lot of problems caused by an earthquake. The seismic analysis of the structure has been great concern in the engineering society with an effort to reduce the severe damages from an earthquake. So the earthquake resistant design is one of the crucial design procedures of a gate valve used in nuclear power generation. The gate valve which has the contact area between stem and bellows. Because of the contact area. The gate valve should be given high stress and frictional wear. In this thesis, Considering the gate valve which has some contact distance between stem and bellows. The gate valve which has some contact distance is analyzed by a commercial FEM code of Ansys and Then compared to the gate valve behavior which doesn't have contact distance.

  • PDF

고강도 알루미늄 합금의 프레팅 피로거동 (Fretting Fatigue Behavior of High Strength Aluminum Alloys)

  • 최성종;이학선;이철재;김상태
    • 대한기계학회논문집A
    • /
    • 제31권2호
    • /
    • pp.197-204
    • /
    • 2007
  • Fretting is a contact damage process that occurs between two contact surfaces. Fretting fatigue reduces fatigue strength of the material due to low amplitude oscillatory sliding and changes in the contact surfaces of strongly connected machine and structure such as bolt, key, pin, fixed rivet and connected shaft, which have relative slip of repeatedly extreme low frequency amplitude. In this research, the fretting fatigue behavior of 2024-T3511 and 7050-T7451 aluminum alloys used mainly in aircraft and automobile industry were experimentally estimated. Based on this experimental wort the following results were obtained: (1) A significant decrease of fatigue lift was observed in the fretting fatigue compared to the plain fatigue. The fatigue limit of 2024-T3511 aluminum alloy decreased about 59% while 7050-T7451 aluminum alloy decreased about 75%. (2) In 7050-T7451 specimen using ATSI4030 contact pad, crack was initiated more early stage than using 2024-T3511 contact pad. (3) In all specimens, oblique cracks were initiated at contact edge. (4) Tire tracks and rubbed scars were observed in the oblique crack region of fracture surface.

모아의 조기 접촉이 모성의 애착행위에 미치는 영향 (Effects of Early Contact on Maternal Infant Attachment)

  • 성미혜;최명란;엄옥봉
    • 여성건강간호학회지
    • /
    • 제16권2호
    • /
    • pp.177-185
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effects of early contact between mothers and infants on attachment behaviors. Methods: The participants were purposely allocated to an experimental group (n=20) and a control group (n=20). For the experimental group, early contact between mothers and newborns took place for 10 minutes. Mother-infant attachment was assessed in the nursery. Data analysis was done using frequency, percentage, $x^2$ test, mean, standard deviation, and t-test with the SPSS/WIN program. Results: The experimental group practicing early mother-infant contact, showed a higher degree of identifying behaviors (p<.05), modalities of interaction (p<.05), and caretaking behaviors (p<.05) than the control group. Conclusion: The early mother-infant contact at 2 hours post-delivery had positive effects on mother-infant attachment. Therefore an early contact can be recommended for all mothers-to-be as a way of improving mother-infant relationships.

COVID-19 팬데믹 시기 간호대학생의 사회접촉과 자살사고: 우울, 외로움의 매개효과 (Influence of Social Contact on Suicidal Ideation among Nursing Students during the COVID-19 Pandemic: The Mediating Effects of Depression and Loneliness)

  • 김남이;김지은
    • 한국학교보건학회지
    • /
    • 제36권2호
    • /
    • pp.31-39
    • /
    • 2023
  • Purpose: Over the past two years, most Korean nursing students had to go through distance learning due to the COVID-19 pandemic. During the pandemic, amental health crisis has emerged among nursing students in South Korea. The study aimed to examine the relationships among social contact, depression, loneliness, and suicidal ideation. Methods: A cross-sectional survey design was used to collect data from nursing students. The survey was conducted onlinein South Korea. A total of 184 nursing students were recruited from December 2021 to April 2022. For data analysis,the frequency, percentage, mean and standard deviation of the general characteristics of the subjects were calculated using IBM/SPSS Statistics 25.0. To examine the mediating effect of depression and loneliness on the relationship between social contact and suicidal ideation, multiple linear regression was used to analyze associations among social contact, depression, loneliness, and suicidal ideation. Results: The average age was 22.69±5.66 years (range=18~54), and the sex distribution was 155 females among 184 nursing students. Lower social contact among nursing students was significantly associated with higher depression and loneliness. Loneliness significantly mediated the relationship between social contact and suicidal ideation innursing students. Conclusion: The findings suggest that strategies for enhancing social contact and reducing depression and loneliness should be considered to improve suicidal ideation among nursing students.

콘택트 렌즈의 탄성에 관한 연구(I) : 진동에 의한 영향 (Elastic Behavior of Contact Lense(I) : Effect of Vibration)

  • 김대수
    • 한국안광학회지
    • /
    • 제4권2호
    • /
    • pp.1-16
    • /
    • 1999
  • 주기적으로 변하는 압력이 탈수상태의 HEMA 콘택트 렌즈에 작용하여 진동이 발생하는 경우, 렌즈상의 임의의 위치에서 파형과 평균진폭을 예측할 수 있는 미분방정식과 컴퓨터 프로그램을 유도하였다. 중심부분의 두께 0.08mm, 직경 14mm, 곡율반경 8mm 렌즈의 고유 공진진동수는 추가질량감소법에 의해 5730 Hz으로 측정되었다. 진동에 주로 관여하는 렌즈의 유효반경의 측정값과 고유 공진 진동수값으로부터 base curve를 가지고 있는 상태에서 렌즈의 탄성율(Young's modulus)을 구할 수 있었으며, 본 실험에 사용한 렌즈에서는 그 값이 $4{\times}10^9$ Pa으로 구해졌다. 파동방정식과 탄성이론에 기초를 두고 유도한 컴퓨터 모델을 작동하여 렌즈의 유효 반경, 렌즈두께, damping, 압력진폭, driving 압력의 진동수 등의 변수가 진동에 미치는 영향을 모사하였다. 렌즈의 유효반경이 클수록, 렌즈의 두께가 얇아 질수록 공진진동수는 낮아지며, 공진진동수 감소에 따라 평균진폭의 급격한 증가가 예측되었다. 외부 압력의 진동수가 렌즈의 고유진동수의 정배수에 접근하는 경우 diaphram의 진동 파형은 원호형에서 파도 또는 종(bell)형으로 전환되며 결과적으로 중심부근의 진폭이 갑자기 상승하게 될 것으로 예상된다.

  • PDF