• Title/Summary/Keyword: Contact Angle Measurement

Search Result 357, Processing Time 0.03 seconds

Characterization of Silk Fibroin/S-carboxymethyl Kerateine Surfaces: Evaluation of Biocompatibility by Contact Angle Measurements

  • Lee, Kuen-Yong
    • Fibers and Polymers
    • /
    • v.2 no.2
    • /
    • pp.71-74
    • /
    • 2001
  • Surface characterization of materials has been considered critical in the development of biomaterials, as many unfavorable responses from the body occur at the interface between a material and the body component. The contact angle measurement is one means to characterize the surface properties and to correlate them to the biocompatibility of materials. In this paper, surface characteristics of silk fibroin/S-carboxymethyl kerateine, representative fibrous proteins, were investigated by contact angle measurements of ESCA. The biocompatibility of the blends was evaluated based on minimal interfacial free energy concept, and compared with other potential biomaterials. It was also hypothesized that the enhanced surface polarity of the blends was generated from the conformational transition of proteins. This approach to evaluate the biocompatibility of materials based on surface characteristics may find wide utility in many biomedical applications.

  • PDF

The Effect of Low Temperature Plasma on the Properties of Foam (저온플라즈마 처리가 발포체의 특성에 미치는 영향)

  • Park, Cha-Cheol;Kim, Ho-Jung
    • Textile Coloration and Finishing
    • /
    • v.17 no.6 s.85
    • /
    • pp.36-41
    • /
    • 2005
  • The effects of low temperature plasma treatment on the properties of three types of foams, polyurethane(PU), injection phylon(IP), and phylon(PH) that used for footwear mid-sole were examined. The change of surface properties of foams were characterized by electron scanning microscope, contact angle measurement, and universal testing machine. Adhesion was tested by T-peel tests of plasma treated foams/polyurethane adhesive joints. The contact angle of three types of foams were decreased dramatically with the plasma treatment time, specifically noticeable in the case of phylon(Ph). It has shown the relationship with the contact angle of phylon(PH) and the distance between electrode and samples. The peel strength of foams were increased with the increase of plasma treatment time.

Nozzle Swing Angle Measurement Involving Weighted Uncertainty of Feature Points Based on Rotation Parameters

  • Liang Wei;Ju Huo;Chen Cai
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.300-306
    • /
    • 2024
  • To solve the nozzle swing angle non-contact measurement problem, we present a nozzle pose estimation algorithm involving weighted measurement uncertainty based on rotation parameters. Firstly, the instantaneous axis of the rocket nozzle is constructed and used to model the pivot point and the nozzle coordinate system. Then, the rotation matrix and translation vector are parameterized by Cayley-Gibbs-Rodriguez parameters, and the novel object space collinearity error equation involving weighted measurement uncertainty of feature points is constructed. The nozzle pose is obtained at this step by the Gröbner basis method. Finally, the swing angle is calculated based on the conversion relationship between the nozzle static coordinate system and the nozzle dynamic coordinate system. Experimental results prove the high accuracy and robustness of the proposed method. In the space of 1.5 m × 1.5 m × 1.5 m, the maximum angle error of nozzle swing is 0.103°.

Measurement of Dynamic Contact Angle of Droplet on Moving Hydrophobic and Hydrophilic Surfaces (이동하는 소수성 및 친수성 표면에서 액적의 동접촉각 측정)

  • Song, Jungyu;Kim, Hyungdae
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.16-22
    • /
    • 2018
  • This study investigates dynamic wetting behaviors of a water droplet placed on surfaces with different wettability and nano-structures. Hydrophobic and hydrophilic properties on as-received silicon wafers were prepared by fabricating thin films of hydrophobic polymer and hydrophilic nanoparticles via layer-by-layer coating. Dynamic advancing contact angle of droplets on the prepared surfaces was measured at various moving velocities of triple contact line with a high-speed video camera. As advancing velocity of triple contact line increased, dynamic advancing contact angle on the as-received silicon and hydrophobic surfaces sharply increased up to $80^{\circ}$ in the range of order of mm/sec whereas the SiO2 nanoparticle-coated hydrophilic surface maintained low contact angles of about $30^{\circ}$ and then it gradually increased in the velocity range of order of hundred mm/sec. The improved dynamic wetting ability observed on the nanostructured hydrophilic surface can benefit the performance of various phase-change heat transfer phenomena under forced convective flow.

A Study on the Super-hydrophobicity of Poly(ethylene terephthalate) Fabric by TiO2 Nano-particles Coating (TiO2 나노입자 코팅에 의한 PET섬유의 초발수성에 관한 연구)

  • Park, Sung-Min;Kwon, Il-Jun;Kim, Ji-Yeon;Kim, Chang-Nam;Yeum, Jeong-Hyun;Yoon, Nam-Sik
    • Textile Coloration and Finishing
    • /
    • v.21 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Studies on plants such as lotus leaf suggested that dual-scale structure could contribute to super-hydrophobicity. We introduced super-hydrophobicity onto poly(ethylene terephthalate)(PET) fabric with dual-scale structure by assembling $TiO_2$ nano sol. PET fabric was treated with $TiO_2$ sol, water-repellent agent using various parameters such as particle size, concentration. Morphological changes by particle size were observed using field emmission scanning electron microscopy(FE-SEM) and AFM measurement, contact angle measurement equipment. The contact angle of water was about 138.5$^{\circ}$, 125.8$^{\circ}$, 125.5$^{\circ}$ and 108.9$^{\circ}$ for PET fabric coated with 60.2nm, 120.1nm, 200nm and 410.5nm $TiO_2$ particles, compared with about 111.5$^{\circ}$ for PET fabric coated with water repellent. When we mixed particle sizes of 60.2nm and 120.1nm by 7:3 volume ratio, the contact angle of water was about 132.5$^{\circ}$. And we mixed particle sizes of 60.2nm and 200nm by 7:3 volume ratio, the contact angle of water was about 141.8$^{\circ}$. Also we mixed particle sizes of 60.2nm and 410.5nm by 7:3 volume ratio, the best super-hydrophobicity was obtained. In this paper, we fabricated various surface structures to the water-repellent surfaces by using four types of $TiO_2$ nano-particles, and we found that the nanoscale structure was very important for the super-hydrophobicity.

Characterization of Fluorocarbon Thin Films by Contact Angle Measurements and AFM/LFM (접촉각 측정과 AFM/LFM을 이용한 불화 유기박막의 특성 평가)

  • 김준성;차남구;이강국;박진구;신형재
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 2000
  • Teflon-like fluorocarbon thin film was deposited on various substrates by vapor deposition using PFDA (perfluorodecanoic acid). The fluorocarbon films were characterized by static/dynamic contact angle analysis, VASE (Variable-angle Spectroscopic Ellipsometry) and AFM/LFM (Atomic/Lateral Force Microscopy). Based on Lewis Acid/Base theory, the surface energy ($S_{E}$) of the films was calculated by the static contact angle measurement. The work of adhesion (WA) between de-ionized water and substrates was calculated by using the static contact data. The fluorocarbon films showed very similar values of the surface energy and work of adhesion to Teflon. All films showed larger hysteresis than that of Teflon. The roughness and relative friction force of films were measured by AFM and LFM. Even though the small reduction of surface roughness was found on film on $SiO_2$surface, the large reduction of relative friction farce was observed on all films. Especially the relative friction force on TEOS was decreased a quarter after film deposition. LFM images showed the formation of "strand-like"spheres on films that might be the reason far the large contact angle hysteresis.

  • PDF

Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer (3종의 자가부식 프라이머의 상아질계면 접촉각 및 미세인장결합강도에 관한 연구)

  • Chang, Seok-Woo;Kwon, Ho-Beom;Yoo, Hyun-Mi;Park, Dong-Sung;Oh, Tae-Seok;Bae, Kwang-Shik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • The purpose of this study was to evaluate the contact angle made by 3 kinds of self etching primers (Clearfil SE Bond, AdheSE, and Tyrian) on dentin and to measure the microtensile bond strength of resin composite to dentin using these self-etching primers. Contact angle between each of 3 self etching primers and polished dentin surface was measured (n=30) by contact angle analyzer and the result was analyzed by One-way ANOVA. For the measurement of microtensile bond strength, polished dentin surface was treated with each of 3 self etching primers and dentin adhesives. Z-250 composite resin was built-up with a height of 5 mm on the adhesive-treated surface and light cured for 40s with a halogen light curing unit. Thereafter, each tooth was sectioned into slabs perpendicular to the bonded interface and trimmed (n=45). The microtensile bond strength was measured with universal testing machine and the result was analyzed with Kruskal-Wallis test. AdheSE group showed the highest contact angle followed by Clearfil SE group and Tyrian group (p<0.05). AdheSE group and Clearfil SE group showed significantly higher microtensile bond strength than Tyrian group (P<0.05).

Measuement of Apparent Contact Angle in Yarn Using Microscope (광학 현미경을 이용한 실에서의 접촉각 측정)

  • 오동원;이광배
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.04a
    • /
    • pp.127-133
    • /
    • 1997
  • Authors measured the apparent contact angle in a yarn using microscope because it gives a useful information in the evaluation of comfort factors in fabrics. The mechanical stage of microscope was designed and built to facilitate this measurement. Variables examined were the fiber type, the twisting number, and the fluid type. All produced significant effect most of which could be rationalized based on the known concepts. The methodology used and the results obtained are discussed in detail.

  • PDF

Analysis of the Surface Characterisitics of Microstickies by Contact Angle Measurement (접촉각 측정을 통한 스틱키의 표면화학적 특성 분석)

  • Park, Il;Lee. Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.2 s.110
    • /
    • pp.21-29
    • /
    • 2005
  • Increase in the utilization rate of recycled paper has significantly increased the problem associated with stickies. Despite the effort to eliminate contaminants from recycled furnishes, stickies are still the most serious obstacle in using recycled paper. The amount of micro stickies that are too small to be eliminated by screening, tends to increase significantly as the closure level of white water system is increased and the quality of raw material deteriorates. To establish a process efficient in removing micro stickies is strongly required. In this study, the surface characteristic of micro stickies was investigated with contact angle measurement. Surface energies of MCC, PSA film and model micro stickies were 53.37 mN/m, 29.75mN/m, and 29.63mN/m, respectively. This indicates that the surface characteristic of MMS is very similar to PSA. Thus, solvent coating of PSA and evaporation of the solvent provided excellent model micro stickies for flotation experiment.

Analysis of the Surface Degradation in UV-irradiated High-Temperature Vulcanized Silicone Rubber (자외선 조사된 HTV 실리콘 고무의 표면열화 분석)

  • 연복희;이태호;허창수;이종한
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.411-419
    • /
    • 2000
  • In this paper we have investigated the surface degradation by ultraviolet-irradiation in high-temperature vulcanized silicone rubber. Through the measurement of surface potential decay by corona-charging and of contact angle it is found that the change of surface electrostatic properties and the decrease of contact angle under UV-radiation. For the changes in micro-morphological and chemical structure of the UV-treated silicone rubber we utilized several analytical techniques such as SEM, ATR-FTIR,XPS. From this study it is shown that the chemical reactions(scissoring of side chain(S-$CH_3$) cross-linking and branching) occur on the surface of silicone rubber during the UV-irradiation. Also we obtained the results of the loss of low molecular weight chain by cross-linking and oxidation reaction.

  • PDF