• Title/Summary/Keyword: Contact Angle Image

Search Result 59, Processing Time 0.033 seconds

A Kinematic Analysis of Gait Patterns between the Normal Men and the Lower Limb Handicapped (정상인과 하지장애자의 보행형태에 대한 운동학적 분석)

  • Kim, Moo-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.163-180
    • /
    • 2003
  • This paper aims at collecting the guantitative data of kenematic variables by analysing the gait patterns of the normal adult men and the handicapped. The gait motions were taped with 4 video cameras, the cinematographic analyses were performed by the DLT technique of three dimensional image treatment. The following results were obtained in the analysis of the variables: 1. The ratio of stance time and swing time did not show any significant difference in the groups of the normal men and the handicapped when both foot of the former and the right feet of the latter were compared. The stride peeriod time of these two groups were 1.12 and 1.11 second, respectively. 2. In the handicapped group, the step width was wider, the step length and stride length were shorter, and especially, the step length of the right foot was shorter, 3. The small vertical displacement of left toes of the handicapped group showed that the heal contact and the left midstance are almost simultaneous. 4. The two groups have almost the same horizontal displacement of the center of gravity and the same vertical rate of extension. In view of the velocity of the center of gravity the normal adults showed the constant speed of movement. However, the handicapped adults were reduced from the right midstance to the right toe-off. 5. The handicapped showed prominently low angle on the left toe-off in the ankle joint angle, they also had the tendency to walk in the patterns of extended knee in the knee joint angle. Both the handicapped and the normal had the hyperextension on the toe-off in the hip joint angle. In the back and front angle of body, both showed the slightly back-sided walking positions. 6. Both groups had the abduction of both feet in foot placement angle, but the handicapped did not show serious abduction of left midstance.

Opticla Angle Sensor Using Pseudorandom-code And Geometry-code (슈도 랜덤 코드와 기하학 코드를 이용한 광학적 Angle Sensor)

  • 김희성;도규봉
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.2
    • /
    • pp.27-32
    • /
    • 2004
  • Absolute optical angle sensor is described that is an essentially digital opto-electronic device. Its purpose is to resolve the relative and absolute angle position of coded disk using Pseudorandom-code and Geometry-code. In this technique, the angular position of disk is determined in coarse sense first by Pseudorandom-code. A further fine angular position data based on Pixel count is obtained by Geometry-code which result 0.006$^{\circ}$ resolution of the system provided that 7 ${\mu}{\textrm}{m}$ line image sensor are used. The proposed technique is novel in a number of aspects, such that it has the non-contact reflective nature, high resolution of the system, relatively simple code pattern, and inherent digital nature of the sensor. And what is more the system can be easily modified to torque sensor by applying two coded disks in a manner that observe the difference in absolute angular displacement. The digital opto-electronic nature of the proposed sensor, along with its reporting of both torque and angle, makes the system ideal for use in intelligent vehicle systems. In this communication, we propose a technique that utilizes Pseudorandom-code and Geometry-code to determine accurate angular position of coded disk. We present the experimental results to demonstrate the validity of the idea.

Surface Modification of Poly(vinylidene fluoride) Membranes using Surface Modifying Macromolecules (SMMs) and Their Application to Pervaporation Separation (SMMs을 이용한 고분자막의 표면개질과 이의 투과증발분리 연구)

  • Rhim, Ji-Won;Lee, Byung-Seong;Kim, Dae-Hoon;Lee, Bo-Sung;Yoon, Seok-Won;Im, Hyeon-Soo;Moon, Go-Young;Nam, Sang-Yong;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.206-213
    • /
    • 2008
  • Poly(vinylidene fluoride) (PVDF) membrane surfaces were modified using surface modifying macromolecules (SMMs). The Zonyl BA-L as SMM was used and the various PVDF membranes containing 0 to 2 wt% SMM were prepared. The resulting membranes were characterized through SEM, contact angle measurements and pervaporation separation of water-ethanol system. SMM layers were created in the surface regions of PVDF membranes by SEM images and the contact angles were increased more than untreated PVDF membranes. The pervaporation was carried out at 50, 60 and $70^{\circ}C$, and the PVDF membranes containing 1 and 2 wt% SMM were used for 10, 20, 50 wt% water in the binary water/ethanol mixtures and pure water. PVDF/2 wt% Zrlnyl BA-L membrane showed the permeability 5.3 $g/m^2hr$ and separation factor 287 at $50^{\circ}C$ for water : ethanol = 10 : 50 solution.

Machining Characteristics according to Electrochemical Polishing (ECP) Conditions of Stainless Steel Mesh (스테인리스 망의 전기화학 폴리싱(ECP) 조건에 따른 가공 특성)

  • Kim, Uk Su;Park, Jeong Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.41-48
    • /
    • 2015
  • Stainless steel mesh has been used as a filter in various fields, including domestic, medical, etc. However, the surface before machining may have an adverse effect the product quality and performance because it is not smooth. Especially, adsorbed impurities in the surface result in difficulty in cleaning. Therefore, in this paper, we propose an improved surface quality through electrochemical polishing (ECP). Two electrodes, composed of STS304 (anode) and copper (cathode) underwent machining with two conditions according to polishing time and current density. As the polishing time and current density increase, the surface of curvature decreases, and roughness and material removal rate (MRR) improves. The machined surface roughness and image were obtained through the atomic force microscope (AFM) and stereoscopic microscope. The study also analyzed hydrophilic effect through contact angles. This obtains corrosion resistance, smoothness, hydrophilic property, etc.

Studies on the Secondary Battery Application of the Surface Fluorinated Microporous PE Separator Membranes (표면 불소화된 미세다공성 PE 격리막의 이차전지 적용을 위한 연구)

  • Byun, Hong-Sik;Kim, Dae-Hoon;Cho, Hyun-Il;Lee, Byung-Seong;Hong, Byung-Pyo;Lee, Sang-Yun;Nam, Sang-Yong;Seo, Myung-Su;Rhim, Ji-Won
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.75-83
    • /
    • 2008
  • In this research, the research for enhancing the stability at the mechanical strength and thermal stability and high power through the Direct Fluorination of the Polyethylene (PE, Asahi) for secondary battery was conducted. The surface of according to the fluorine gas exposure time and constructional change were observed through the scanning electron microscope image, and the contact angle. The mechanical property was confirmed through the tensile strength and surface hydrophilic property experiment. Charge and discharge experiment, the lifetime property, and the overcharge test were performed in order to confirm the electrochemical characteristic of produced and we confirmed at the high power that the stability about a temperature was improved.

Process Characteristics of Atmospheric Pressure Plasma for Package Substrate Desmear Process (패키지 기판 디스미어 공정의 대기압 플라즈마 처리 특성)

  • Ryu, Sun-Joong
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.5
    • /
    • pp.337-345
    • /
    • 2009
  • When the drill hole diameter for the package substrate is under $100{\mu}m$, the smear in the drill hole cannot be eliminated by wet desmear process only. We intended to change the substrate's hydrophobic characteristics to hydrophilic characteristics by adapting the atmospheric pressure plasma prior to the wet desmear process. Atmospheric pressure plasma process was made as the inline type equipment which is adequate for the package substrate's manufacturing process and remote DBD type electrodes were used for the equipment. As the result of atmospheric pressure plasma processing, the contact angle of the substrate was enhanced from 71 degree to 30 degree. Dielectric film thickness, drill hole diameter and surface roughness were measured to evaluated the characteristics of the wet desmear process in case of plasma processing and in case of none. By the measurement, it was analyzed that the process uniformity within the whole panel was largely enhanced. Also, it was verified that the smear in the drill hole was eliminated efficiently which was analyzed by the SEM image of the drill hole.

Surface characteristics and bioactivity of an anodized titanium surface

  • Kim, Kyul;Lee, Bo-Ah;Piao, Xing-Hui;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.198-205
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Methods: Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse $MC_3T_3-E_1$ cells. Results: The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide ($TiO_2$) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized $TiO_2$ surface showed significantly enhanced alkaline phosphatase activity (P<0.001). Conclusions: These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.

A Study of the Shaft Power Measuring System Using Cameras (카메라를 이용한 축계 비틀림 계측 장치 개발)

  • Jeong, Jeong-Soon;Kim, Young-Bok;Choi, Myung-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.72-77
    • /
    • 2010
  • This paper presents a method for measuring the shaft power of a marine main engine. Usually, in traditional systems for measuring shaft power, a strain gauge is used even though it has several disadvantages. First, it is difficult to set up the strain gauge on the shaft and acquire the correct signal for analysis. Second, it is very expensive and complicated. For these reasons, we investigated alternative approaches for measuring shaft power and proposed a new method that uses a vision-based measurement system. For this study, templates for image processing and CCD cameras were installed at the both ends of the shaft. Then, in order for the cameras to capture the images synchronously, we used a trigger mark and a optical sensor. The position of each template between the first and the second camera images were compared to calculate the torsion angle. The proposed measurement system can be installed more easily than traditional measurement systems and is suitable for any shaft because it does not contact the shaft. With this approach, it is possible to measure the shaft power while a ship is operating.

Texture Feature Analysis of Machined Surface Image Using Intensity Gradient (광 강도변화를 이용한 가공면 영상의 텍스쳐 특징분석)

  • 사승윤
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.49-56
    • /
    • 1998
  • Super precision working technique and machine tool have been continually developed thanks to advanced electronic field. To obtain good result. it is necessary to investigate surface in grinding with $mu extrm{m}$ level. There were quite many researches to satisfy these demands by using non-contact methods through the computer vision. In this study, the texture of working surface was analyzed. co-occurrence matrices was obtained from the surface roughness. Texture parameter was obtained using position operator composed of $ heta$, d according to variation of angle direction and distance. As a result, it was found that surface texture was more affected by direction($\theta$) than distance(d).

  • PDF

Experimental Study on Micro PIV Measurement using a Micro Liquid Lens (마이크로 유체렌즈를 이용한 마이크로 PIV 측정에 관한 실험적 연구)

  • Jeong, S.R.;Dang, T.D.;Choi, J.H.;Kim, G.M.;Park, C.W.
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.22-28
    • /
    • 2010
  • In the present study, we performed the velocity field measurement in a microchannel using a focal length variable micro liquid lens. The liquid lens is used as a beam expander in a micro-PIV system to acquire the scatter image of the seeded particle. A thin film-type micro liquid lens was made of PDMS material and it was attached on top of the 700-micron-wide working fluid supply channel trench. As a result, the focal length and contact angle of the liquid lens changed with variations in applied pressure.