• Title/Summary/Keyword: Construction site operation

Search Result 294, Processing Time 0.022 seconds

Evaluation of seismic performance of road tunnels in operation (운영 중인 도로 터널의 내진 성능 평가)

  • Ahn, Jae-Kwang;Park, Du-Hee;Kim, Dong-Kyu;Kim, Kwang-Yeom
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.69-80
    • /
    • 2013
  • This study evaluates the seismic performance of road tunnels designed before the provisions for seismic design of tunnels were first established in 1999. Extensive design data and site investigation reports are investigated to select tunnels sections that are considered to be most susceptible to seismically induced damage under earthquake loading. Detailed analyses are performed on selected tunnels. The methods used are method of displacement and dynamic analysis. In performing the method of displacement, which is a type of pseudo-static analysis method used for underground structures, full domain and reduced domain modeling were used. The dynamic analyses are performed using finite difference method and using nonlinear constitutive model. Comparisons show that the reduced domain method of displacement match very closely with the dynamic analysis, demonstrating that it is the most suitable method for evaluating the seismic performance of road tunnels built in rocks. It is also shown that road tunnels, for which seismic design were not applied, are safe under the seismic risks corresponding to an earthquake with a return period 1000 years. It is concluded that additional seismic retrofit of tunnels is not necessary.

A Study on the Prevention of Lightning Accidents According to Climate Change Response (기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구)

  • Ju, Suk-won;Kim, Seong-Bin;Rie, Dong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.48-55
    • /
    • 2020
  • The installation of lightning protection system has recently been increasing, but the amount of damage has still been increasing. In this study, survey (interview) and field conditions were conducted to identify the installation and safety standards of the lightning protection system. it was analyzed that the safety management system is non-existent at the stage of the design, manufacturing and construction of the site lightning protection system, and that the safety inspection of the lightning protection facility is not properly managed. It has been shown that lightning protection systems, that can solve these problems, need to be re-established according to the reality so that safety inspection can be carried out in accordance with safety standards such as management of safety certification products, operation of survey institutions, design, manufacturing, and construction of safety standards at a national level.

Effect of the Reactive Power Compensation System on Performance Enhancement in a 900 MW Combined Cycle Power Plant (무효전력보상장치 설치가 900 MW 복합화력발전소의 성능향상에 미치는 효과)

  • Lee, Young Ok;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.2
    • /
    • pp.48-53
    • /
    • 2021
  • In the case of a 900 MW combined cycle power plant, most of the load on the site is a rotating device and is operated at a low power factor, and the power factor decrease increases the reactive power, which causes the efficiency of the device to be consumed and unnecessary unnecessary power consumption. This study intends to present the results by installing and operating a reactive power compensation device that absorbs and removes reactive power, which is a solution to this problem, on a 6.9 kV on-board bus. As a result of application of this system, first, it was confirmed that the power factor of the rotating machine was improved to 0.22 and the load power in the house was reduced by 1.4%, and the thermal efficiency of the generator was increased by 0.1% and the power generation power by 810 kW. Next, it was confirmed that the cost of construction and operation can be reduced in the future due to economic feasibility, with a decrease of 200 million won/year in electricity loss compared to 1.5 billion won in investment, an increase of 1 billion won/year in sales, and a one-year capital recovery period.

A Study on Practicalization of Low Vibration New KINRECKER-II (미진동 발파용 New KINECKER-II 실용화에 관한 연구)

  • Jang, Seung-Ho;Park, Hee-Won;Lim, Jung-Hyuk;Lee, Chang-Yeop;Ahn, Bong-Do;Kang, Dae-Woo;Lee, Ha-Young
    • Explosives and Blasting
    • /
    • v.35 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • Mountain and hill areas occupy by more than 70% in South Korea and Rock drilling should be applied in order to reduce noisy & vibration from massive civil engineering business such as road expansion, high-way construction, subway construction and construction of site renovation such as a newly-built & re-development of apartment, newly-built of high-rising building in downtown area. As Blasting noise & vibration such as vibration, noise, fly rock etc caused by blasting operation from large small scale construction occurs, neighboring residents who demand the compensation file a civil complaint so that the business reach a deadlock. As the excavation method for these areas, There are blasting of micro-vibration, mechanical excavation method(Rock splitter, Breaker etc), similar blasting method(plasma, gel fragmentation etc) to date. In this study, we are trying to find the feature & performance which get improved economic feasibility & construct ability through improving sympathetic detonation of New KINECKER-I used in blasting of micro-vibration & formulation and would provide convenience for use by introducing standard blasting pattern & construction method. Also, checked and confirmed all the blasting with connecting cap has been cleary detonated.

Preliminary Assessment Model based on BSC for Evaluating Practical Utilization of 4D CAD System (4D CAD 시스템의 실무적 활용성 평가를 위한 BSC기반의 예비 평가 모델)

  • Kim, HyeonSeung;Moon, HyounSeok;Kang, LeenSeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.2069-2079
    • /
    • 2013
  • Recently, BIM(Building Information Modeling) is on the rise as a customized solution for construction environment, but construction companies rarely introduce and apply BIM in the construction site. Due to such issues, the fact that empirical data for evaluating the quantitative effect of BIM application is insufficient might be an another main reason. In the end, construction companies cannot assure investment effect of BIM and therefore don't make an investment actively. To activate BIM application, the evaluation system that quantitatively assess usability of BIM needs to be developed. This study aims to suggest a methodology that evaluates the usability quantitatively according to introduction and operation of BIM by construction companies. Accordingly, this study analyzes applicability of 4D CAD by developing an evaluation index and its model with BSC(Balanced Score Card) for 4D CAD, which have high practical use among BIM techniques, and verifies the usability as the entire evaluation index of BIM. Therefore, it is expected that the developed assessment model will be utilized as the critical decision-making information in order to introduce related techniques by identifying the usability and operational issues of 4D CAD.

A Deep-Learning Based Automatic Detection of Craters on Lunar Surface for Lunar Construction (달기지 건설을 위한 딥러닝 기반 달표면 크레이터 자동 탐지)

  • Shin, Hyu Soung;Hong, Sung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.859-865
    • /
    • 2018
  • A construction of infrastructures and base station on the moon could be undertaken by linking with the regions where construction materials and energy could be supplied on site. It is necessary to detect craters on the lunar surface and gather their topological information in advance, which forms permanent shaded regions (PSR) in which rich ice deposits might be available. In this study, an effective method for automatic detection of lunar craters on the moon surface is taken into consideration by employing a latest version of deep-learning algorithm. A training of a deep-learning algorithm is performed by involving the still images of 90000 taken from the LRO orbiter on operation by NASA and the label data involving position and size of partly craters shown in each image. the Faster RCNN algorithm, which is a latest version of deep-learning algorithms, is applied for a deep-learning training. The trained deep-learning code was used for automatic detection of craters which had not been trained. As results, it is shown that a lot of erroneous information for crater's positions and sizes labelled by NASA has been automatically revised and many other craters not labelled has been detected. Therefore, it could be possible to automatically produce regional maps of crater density and topological information on the moon which could be changed through time and should be highly valuable in engineering consideration for lunar construction.

A Study on the Correlation between the Building Perimeter and Safety Management Cost (건물의 외주길이와 안전관리비의 상관관계 분석에 관한 연구)

  • Han, Bum-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.4
    • /
    • pp.359-370
    • /
    • 2022
  • Despite continuous efforts to reduce on-site safety accidents, the construction industry remains a high-risk sector with a high rate of fatal accidents. Design for Safety(DFS), which manages safety risk factors at the design stage, is being used as a method to lower the construction safety accident rate. However, due to limited knowledge, designers are unaware of the design-results risks during the different of the project lifecycle, including construction, operation, and maintenance. Effective DFS can be conducted if the designer understands the effect of the building shape on the safety accident rate and corresponding safety management cost(SMC). The cost of safety facilities such as fall prevention nets and safety fences will vary depending on the shape of the building. This study analyzes the outer perimeter length's impact on SMC. Following the data collection from 21 projects for this study, an analysis was conducted using the independent variables of the building perimeter(BP), building shape factor(BSF), and building area(BA), the dependent variable of SMC. The correlation R2 was found to be 0.876, 0.801 and 0.792 between the BP and SMC, BSF and SMC, BA and SMC, respectively, indicating that these factors were closely related.

Case Study on the Improvement of Pollutant Removal Efficiency in Sihwa Constructed Wetland (시화호 인공습지의 수질정화기능 향상을 위한 사례연구)

  • Choi, Don-Hyeok;Kang, Ho;Choi, Kwang-Soon
    • Journal of Wetlands Research
    • /
    • v.12 no.2
    • /
    • pp.25-33
    • /
    • 2010
  • Three plans(induction of water flow, supply of oxygen into water, control of fish causing resuspension of solids) proposed to improve the pollutant removal efficiency of Sihwa Constructed Wetland(CW) were estimated by considering the their efficiency and application to the wetland. After construction of facility for induction of water flow in lower part(W 122m${\times}$L 103m) of the wetland, the mean removal efficiencies of BOD, SS, TN and TP were in range of 12.8~37.4% and BOD was showing the highest efficiency. This result indicates that water flows is one of very important factors in the pollutant removal of wetland, especially near the outlet of a large scale wetland such as Sihwa CW. Dissolved oxygen(DO) concentrations after operation of two oxygen supply systems such as Air Bubble Diffuser and Surface Aeration System increased 15.5% and 27.2%, respectively. For maintaining effective DO concentration in Sihwa CW, the operation of oxygen supply system may be desirable during midnight to dawn in the location in which DO concentration is not enough, for instance less than 2 mg/L in CW. In experiments of the fish removal from Sihwa CW, the mean turbidity was lower in test site(6.2 NTU) than control site(10.6). The removal efficiency of thurbidity by th fish removal from the wetland was 41.5%. Therefore, a relevant fish management through a periodical monitoring of fish and turbidity is needed.

A Study on Systematic Risk Assessment Method for LNG Storage Facilities (LNG 저장설비에 대한 체계적인 위험성평가 방법에 관한 연구)

  • Kang, Mee-Jin;Lee, Young-Soon;Lee, Seung-Rim
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • As the consumption of LNG has increased, the capacity and number of LNG facilities are getting bigger and bigger. Such circumstances supports the need for a dedicated risk analysis model to help review and check major issues of the safer construction and operation of LNG storage facilities systematically. Therefore this study suggests an appropriate risk analysis model that enables us to evaluate hazards of LNG storage facilities more easily and systematically, and then to use its result in siting, design and construction stages of the facilities. ill order to develop the model, lots of existing studies and domestic and foreign codes and standards were fully reviewed and a series of case studies also were carried out. The suggested model consists of 4-stage evaluations: in selecting a site, in determining a layout, in designing and constructing the facilities, and in operating them. This model also suggests the weather condition necessary for estimating the consequence of accident-scenarios, and the easy, systematic approach to the analysis of their probability. We expect that the model may help secure LNG storage facilities' inherent safety in determining their site and layout.

  • PDF

A Study on Power Generation Efficiency through the Post Evaluation of Photovoltaic Panels in Complex Type Buildings - Focused on Annual Generation Performance of S-university - (단지형 건물군 내 태양광 패널의 사후 평가를 통한 발전 효율 연구 - S대학의 연간 발전 실적을 중심으로 -)

  • Kim, Heejin;Jung, Hyejin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.5
    • /
    • pp.11-19
    • /
    • 2017
  • The purpose of this study is to analyze the efficiency of PV according to installation condition in the complex type buildings. For this purpose, annual performance of solar power generation in a certain area was investigated and various methods were conducted including post operation evaluation. In addition, we tried to find out influencing factors that affect the efficiency and sought to identify their relative impact of degree through the data analysis and site visits together. In the middle of this process we can draw up major considerations for the efficient photovoltaic power generation installation. In the mean while, previous studies are making something new related with method for efficiency enhancement and individual influential factors based on experimental environment rather than the empirical data site based. As a result of the study, it was confirmed that even if installed in the same area, the power generation efficiency is 1.5 times as high as the installation condition. Furthermore, statistical analyses were performed on azimuth, tilted angle and shade, which are variables affecting conversion efficiency, and it was statistically confirmed that all variables are meaningful factors that affect the conversion efficiency which is a dependent variable. The most influential factor is the azimuth, followed by the tilted angle and the shade factor. From this result, we expect to be able to provide installation guidelines for the solar power generation equipments on the rooftop zone.