• 제목/요약/키워드: Construction Capacity

검색결과 2,815건 처리시간 0.031초

중심축압(中心軸壓)을 받는 콘크리트충전(充塡) 각형강관(角形鋼管)기둥의 내력(耐力)에 관한 실험적(實驗的) 연구(硏究) (Experimental Study on Compressive Strength of Centrally Loaded Concrete Filled Square Tubular Steel Columns)

  • 김종성;오윤태;권영환
    • 한국강구조학회 논문집
    • /
    • 제8권4호통권29호
    • /
    • pp.59-76
    • /
    • 1996
  • Concrete filled steel tube column has a large load carrying capacity through its steel and concrete interaction which makes it useful in construction. However, it has not been used often in a practical construction field. This is partly due to the non-destructive inspection method for concrete filling which has yet to be established. Furthermore, there are the lack of test data and a practical method in evaluating the ultimate load carrying capacity of concrete filled steel tube column. This paper will attempt to predict the ultimate strength of short concrete filled square tubular steel columns through conducting several tests. To accumulate the new test data on concrete filled steel tube columns, a total of 42 specimens of steel tubular columns were monotonically tested under concentric axial force, having the slenderness ratio(${\lambda}=10,\;15,\;20$), width-thickness ratio(d/t=25.0, 33.3) and concrete strengths($F_{c}=210,\;240,\;270kg/cm^{2}$). The hollow sections and concrete filled steel columns were compared to check the lateral confinded effects by steel tube. Through these test results, we propose a coefficient k=3.64 for the strength evaluation formula(10) of concrte filled tubular steel short columns.

  • PDF

하이브리드 유기섬유 보강 콘크리트의 제조 및 휨성능 평가 (A Processing and Flexural Performance Evaluation of Hybrid Organic Fiber Reinforced Concrete)

  • Jeon, Chanki;Jeon, Joongkyu;Shim, Jaeyeong
    • 한국재난정보학회 논문집
    • /
    • 제13권2호
    • /
    • pp.213-220
    • /
    • 2017
  • 일반적으로 유기섬유는 섬유 자체의 인장강도 및 탄성계수는 작지만, 내화성 및 내부식성이 우수하고, 콘크리트의 균열 제어 및 내충격 성능 향상에 효과적인 섬유이다. 따라서, 유기섬유는 콘크리트용 보강 섬유로서의 적용성이 매우 높은 재료이다. 본 연구에서는 폴리아미드(PA)섬유와 고강력의 폴리에스터(PET)섬유를 혼입한 하이브리드 유기섬유를 개발하였으며, 하이브리드 유기섬유를 혼입한 섬유보강 콘크리트의 휨성능 시험을 통해 하이브리드 유기섬유 보강 콘크리트의 에너지 흡수능력을 평가하고자 한다.

쐐기형 쏘일 네일의 인발 거동 특성 (Pullout Resistance Characteristics of the Wedge-shaped Soil Nail)

  • 김범주;이용준;윤용수;정민규;윤지남
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1079-1083
    • /
    • 2009
  • In this study, the pullout resistance characteristic of a wedge-shaped soil nail, made by attaching small steel sticks to the tip of a nail in a wedge shape, was investigated. It was developed to improve the overall pullout resistance capacity of the existing soil nail system, composed of nail and grout, by making the wedge provide additional pullout resistance. In order to evaluate the pullout resistance of the wedge shape-soil nail, field pullout tests were conducted, and the results were compared with those for the existing soil nail without the wedge. The field test results showed that the pullout resistance capacity of the wedge-shaped soil nail was 50% larger than that of the existing soil nail without the wedge.

  • PDF

Axial compression behavior of circular recycled concrete-filled steel tubular short columns reinforced by silica fume and steel fiber

  • Chen, Juan;Liu, Xuan;Liu, Hongwei;Zeng, Lei
    • Steel and Composite Structures
    • /
    • 제27권2호
    • /
    • pp.193-200
    • /
    • 2018
  • This paper presents an experimental work for short circular steel tube columns filled with normal concrete (NAC), recycled aggregate concrete (RAC), and RAC with silica fume and steel fiber. Ten specimens were tested under axial compression to research the effect of silica fume and steel fiber volume percentage on the behavior of recycled aggregate concrete-filled steel tube columns (RACFST). The failure modes, ultimate loads and axial load- strain relationships are presented. The test results indicate that silica fume and steel fiber would not change the failure mode of the RACFST column, but can increase the mechanical performances of the RACFST column because of the filling effect and pozzolanic action of silica fume and the confinement effect of steel fiber. The ultimate load, ductility and energy dissipation capacity of RACFST columns can exceed that of corresponding natural aggregate concrete-filled steel tube (NACFST) column. Design formulas EC4 for the load capacity NACFST and RACFST columns are proposed, and the predictions agree well with the experimental results from this study.

폐 난연성 EPS의 혼합조건에 따른 재생골재 블록의 물성에 관한 실험적 연구 (The Physical Properties of the Block Using Flame Resistant EPS Wastes)

  • 조광현;김지현;정철우;이재용;이수용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.152-153
    • /
    • 2013
  • Based on the Fire Service Act of mandatory provision, new buildings are strictly forced to use fire protection materials. Flame resistant EPS is one of those materials. Unlike conventional EPS that can be fused to make EPS ingot and be recycled for various purposes, flame resistant EPS waste cannot be recycled due to the presence of protective coating that is applied to increase the fire protection properties of EPS. A suitable alternative that can process large amount of flame resistant EPS wastes needs to be developed, and one of the possible alternative is to use them as construction materials. In this research, experiments were designed to observe whether the flame resistant EPS wastes can be utilized as partial replacements of fine aggregates in cement mortar. The replacement ratio of waste EPS was varied, and its effect on compressive strength and absorption capacity was investigated. According to the experimental results, both compressive strength and absorption capacity met the Korean Standard specification for cement bricks and blocks, indicating that flame resistant EPS wastes can be used for construction purposes.

  • PDF

비탄성 국부좌굴을 고려한 철골 모멘트 접합부 회전능력 평가를 위한 모델 개발 (Evaluation of Rotation Capacity of Steel Moment Connections ConsideringInelastic Local Buckling - Model Development)

  • 이경구
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.617-624
    • /
    • 2008
  • 잘 설계된 철골 모멘트 접합부의 경우, 유효회전능력에 도달하기 전에 국부좌굴이 발생하고 비탄성 후좌굴 변형이 접합부 회전능력을 정의하는데 중대한 역할을 한다. 이 연구에서는 국부좌굴로 인한 강도저하와 보 소성힌지의 회전을 모델링하여, 단조증가하중 및 반복하중이 작 용하는 특별철골모멘트골조의 강접합 보-기둥 접합부의 회전능력을 예측하기 위한 근사적 해석모델을 제안한다. 제안된 항복선 소성힌지 모델은 좌굴된 소성힌지부의 형상에 기초하여 항복선과 소성존으로 구성되고, 소성메커니즘을 통해 국부좌굴후의 거동까지 포함한 모멘트-회전각 관계를 제 공한다. 향상된 WUF-W 와 RBS 접합부를 위해 제안된 모델을 개발한 후 실험결과와 비교를 통해 검증하였다. 동반논문(변수연구)에서는 광범위 한 H-형강의 기하학적 변수 따른 접합부 회전능력에 대하여 논의하였다.

벽식 구조체 적용을 위한 구조용단열패널 성능 평가 (Evaluation on Structural Performance of Structural Insulated Panels in Wall Application)

  • 나환선;이현주;이철희;황성욱;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.

전단력을 받는 선설치 앵커볼트의 콘크리트 파열파괴강도 평가 연구 (A Study on the Concrete Breakout Capacity of CIP Anchor Bolts under Shear Loading)

  • 박용명;전명희;최명국;김철환;김인기
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.207-215
    • /
    • 2012
  • 전단하중을 받는 앵커볼트의 설계에 $45^{\circ}$ 콘파괴 이론이 그동안 적용되어 왔으나, 2,000년 이후부터 CCD(Concrete Capacity Design) 방법이 새로운 설계법으로 도입되었다. 그러나, 본 방법은 주로 소형 앵커볼트에 대한 실험 결과에 근거한 관계로 앵커볼트의 직경이 50mm 이하인 경우에 한해 적용이 허용되고 있다. 따라서 큰 연단거리를 갖는 중대형 앵커볼트에 대한 합리적인 콘크리트 파열파괴강도식의 도출이 필요한 실정이다. 본 연구에서는 M56 선설치 단일 앵커볼트로 연단거리 350mm에 대해 콘크리트 파열파괴강도 평가를 위해 4개의 시험체에 대해 실험을 수행하였다. 그리고, 본 실험 결과와 타 연구의 실험 결과를 종합하여 연단거리 750mm까지의 큰 연단거리에 대해 새로운 전단파괴강도식을 제안하였다.