Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method (컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1590-1595
    • /
    • 2003
  • Direct drive servovalve(DDV) is a kind of one-stage valve since the rotary motion of DC motor is directly transferred to the linear motion of valve spool through the link. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

  • PDF

Lead-Lag Controller Design of Direct Drive Servo Valve Using Complex Method (컴플렉스법에 의한 직접구동형서보밸브의 진상-지상 제어기 설계)

  • Lee, Seong-Rae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1719-1726
    • /
    • 2004
  • Direct drive servovalve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the DC motor. Since the structure of DDV is simple, it is less expensive, more reliable and offers reduced internal leakage and reduced sensitivity to fluid contamination. However, the flow force effect on the spool motion is significant such that it induces large steady-state error in a step response. If the proportional control gain is increased to reduce the steady-state error, the system becomes unstable. In order to satisfy the system design requirements, the lead-lag controller is designed using the complex method that is one kind of constrained direct search method.

Optimal Design of Hydraulic System Using the Complex Method (컴플렉스법에 의한 유압시스템의 최적 설계)

  • Lee S.R.;Lee Y.B.;Park J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.4
    • /
    • pp.1-8
    • /
    • 2004
  • The optimum design parameters of several hydraulic systems are obtained using the complex method that is one kind of constrained direct search method. First, the parameters of lead-lag controller of the direct drive servovalve is designed using the complex method to satisfy the steady-state error requirement. Second, the optimum locating point of hydraulic cylinder Is determined to minimize the cylinder force in the operation range of rotational sluice gate. For the third application case, the optimum piston area of hydraulic cylinder is determined to minimize the man power to elevate the manually operated sluice gate.

  • PDF

Controller Parameters Design of Direct Drive Servo Valve Using Genetic Algorithm and Complex Method (유전자 알고리즘과 콤플렉스법에 의한 직접구동형 서보밸브의 제어기 상수값 설계)

  • Lee, Seong Rae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.475-481
    • /
    • 2013
  • The control system of a direct drive servo valve is a nonlinear system, and the flow force effect on the spool motion is significant and dependent on the load pressure. To satisfy the control system design requirements, the optimal parameters of the lead-lag controller and the derivative feedback controller are searched for using a genetic algorithm and a complex constrained direct search type method. The obtained controller parameters successfully perform their role to satisfy the control system design requirements.

Design of Optimal Capacity Coefficients of Flow Control Valves in the Hoist Hydraulic System Using the Complex Method (콤플렉스법에 의한 호이스트 유압회로 유량제어밸브의 최적유량계수 설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, two pilot operated check valves, two flow control valves. The capacity coefficients of flow control valves should be adjusted for the hoist to operate at moderate speed and minimize the hydraulic energy loss. However, it is difficult to adjust the four capacity coefficients of flow control valves by trial and error for optimal operation. The steady state model of the hoist hydraulic system is derived and the optimal capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit (카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Optimal Design of a Quick-Acting Hydraulic Fuse using Genetic Algorithm and Complex Method (유전자 알고리즘과 콤플렉스법에 의한 고성능 유압휴즈의 최적 설계)

  • Lee, S.R.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.32-38
    • /
    • 2014
  • The hydraulic fuse, which responds to the suddenly increased flow on rupture of a line and shuts off the fluid flow, would prevent large spillage of liquid. The quick-acting hydraulic fuse, which is mainly composed of a poppet, a seat, and a spring, must be designed to minimize the leaked flow and to prevent high collision speed between the poppet and seat during fuse operation on a line rupture. The optimal design parameters of a quick-acting hydraulic fuse were searched using the genetic algorithm and the complex method that are kinds of constrained direct search methods. The dynamic behavior of a quick-acting hydraulic fuse was researched using computer simulations that applied the obtained optimal design parameters.

Design of Optimal Locating Point of the Hydraulic Cylinder Actuating a Roller-Link Type Rotating Floodgate (콤플렉스법에 의한 롤러-링크 부착형 전도수문 구동용 유압실린더의 최적 설치점 설계)

  • Lee, S.R.
    • Journal of Drive and Control
    • /
    • v.9 no.3
    • /
    • pp.29-36
    • /
    • 2012
  • The hydraulic cylinder is used for actuating the roller-link type rotating floodgate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to the limited space and determined to minimize the cylinder force necessary for actuating the floodgate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the support link. Therefore there exist three design variables to be determined to minimize the cylinder force within the rotating range of floodgate. First, the mathematical model of the roller-link type rotating floodgate is derived to find the cylinder force corresponding to the floodgate angle. Then, the optimal locating point of hydraulic cylinder is searched using the complex method that is one kind of constrained direct search method.

Design of Optimal Locating Points of the Hydraulic Cylinder Actuating a Sluice Gate Using the Complex Method (컴플렉스법에 의한 수문 유압실린더의 최적 설치점 설계)

  • Lee Seong-Rae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.170-176
    • /
    • 2005
  • The hydraulic cylinder is used for actuating the sluice gate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to limited space and determined to minimize the cylinder force necessary for actuating the sluice gate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the gate plate when it is fully opened. Therefore there exist three parameters to be determined to minimize the cylinder force in the operation range of sluice gate. The optimal locating points of hydraulic cylinder are obtained using the complex method that is one kind of constrained direct search m method.

GRID-BASED METHODS FOR LINEARLY EQUALITY CONSTRAINED OPTIMIZATION PROBLEMS

  • Feng, Yan;Zhang, Xuesheng;Liu, Liying
    • Journal of applied mathematics & informatics
    • /
    • v.23 no.1_2
    • /
    • pp.269-279
    • /
    • 2007
  • This paper describes a direct search method for a class of linearly constrained optimization problem. Through research we find it can be treated as an unconstrained optimization problem. And with the decrease of dimension of the variables need to be computed in the algorithms, the implementation of convergence to KKT points will be simplified to some extent. Convergence is shown under mild conditions which allow successive frames to be rotated, translated, and scaled relative to one another.