• Title/Summary/Keyword: Constitutional Engineering

Search Result 94, Processing Time 0.03 seconds

Development and Evaluation of an Self-Operated Face Capturing System (자가 안면영상 촬영장치 개발 및 검증)

  • Jeon, Young-Ju;Do, Jun-Hyeong;Kim, Jang-Wong;Kim, Sang-Gil;Lee, Hae-Jung;Lee, Yu-Jung;Kim, Keun-Ho;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Objectives : The purpose of this study is to develop an apparatus which can take a facial image by self-operated capturing technique. The user can obtain one's facial image immediately after adjusting facial tilt and focusing distance. The system has been designed for classifying Sasang typology based on facial image. Methods : The system is composed of a Webcam, one-way glass mirror and mini LCD. The Webcam takes a facial image which is displayed on the mini LCD. Then the user can see and adjust to the right position in the real time through the image mirror-reflected from the mini LCD. The optical sensor is used to estimate the proper focusing distance. To verify the performance of the system, 11 characteristic points on the facial image are used and compared with high performance DSLR camera(D700) by applying the coefficient of variance and Bland-Altman Plot. Results : The developed system and D700 show enough agreement with the small coefficient of variance to analyse constitutional types with a facial im mage. However, the result of Bland-Altman plot shows that the width parameters have distortions owing to short focusing distance. Conclusions : The system is expected to be utilized on u-healthcare services for home environment after improving the distortion in the width parameters.

A Case Study of Six Sigma Project for Improving Measurement Method of Skin Elasticity (피부탄성 측정 문제점 개선을 위한 6시그마 프로젝트)

  • Lee, Hae-Jung;Kang, Nam-Sik;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Hong-Gie;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.3
    • /
    • pp.135-140
    • /
    • 2010
  • The usefulness of constitutional diagnoses based on skin measurements has been established in oriental medicine. According to Sasang constitutional medicine, humans can be distinguished based on properties of skin's friction, thickness and elasticity. To quantify and standardize skin diagnosis, the present study designed an equipment for measuring skin elasticity of hand. But there were some noises in measuring skin elasticity such as measurement method, environment, operator and conditions of patient. So we considered a six sigma project for reducing the measurement errors. The project was followed to discipline process of five macro phases: Define, Measure, Analyze, Improve and Control(DMAIC). So, we could find the major factors which should be controled for stabilizing measurement system and we revised the SOP(Standard Operating Procedure) of the skin elasticity measurement.

Four Constitution Types Classifier with IndecisionUsing Facial Images (판정불능을 포함한 안면 체질 분류 방법에 관한 연구)

  • Do, Jun-Hyeong;Kim, Sung-Hun;Koo, Im-Hoi;Kim, Keun-Ho;Kim, Jong-Yeol
    • Journal of Sasang Constitutional Medicine
    • /
    • v.21 no.3
    • /
    • pp.39-47
    • /
    • 2009
  • 1. Objectives: In order to classify an individual into four constitution type, an oriental medical doctor utilizes various information such as face, pulse, voice, and questionnaire. When only one type of information is used, one's constitution may not be decided correctly. 2. Methods: In this paper, we propose a novel four constitution types classifier using facial images which classifies subjects into indecision group as well as Taeumin, Soeumin, and Soyangin. 3. Results: Experimental results show that it increases the classification rate though the decision rate is rather decreased, which is more effective and reliable than conventional classifiers without indecision. 4. Conclusion: For the effective classification, we have found that it is more useful to add an indecision group which requires more information to be properly classified into one constitution type.

  • PDF

A Study on Improvement of the O-Ring Measurement System for the Constitutional Diagnosis (체질 진단을 위한 O-링 경근력 계측시스템의 개선에 관한 연구)

  • Kim, Y.Y.;Kim, J.M.;Yang, K.M.;Ko, S.B.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.90-94
    • /
    • 1995
  • In this paper, we improved the O-Ring Measurement System(O-R MS) based on oriental constitutional theory of four classes for objectify constitutional diagnosis by O-Ring test method which is one of effective methods in several constitutional diagnosis. The result of using in a half of year, some problems are pointed out. To settle these problems, we improved the actuator, display module, sensor module, and hardware of controller. Also, the software is supplemented to using the more decision parameters. It is estimated to have a high practical use for the objectified constitutional diagnosis.

  • PDF

Characteristic behaviors of the AIx depending on the palpation positions (맥진 위치에 따른 AIx 변화 특성 연구)

  • Jeon, Young-Ju;Kim, Jae-Uk;Lee, Yu-Jung;Ryu, Hyun-Hee;Lee, Hae-Jung;Woo, Young-Jae;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1966_1967
    • /
    • 2009
  • As an attempt to characterize the pulse behaviors at the three pulse diagnosis positions in the oriental medicine which are called Chon, Gwan, and Cheok, we measure the pluse waveforms by SphygmoCor apparatus, that has been used widely for the evaluation of the arterial stiffness, and examine the Augmentation Index (AIx) at the aorta. For the study, twenty healthy men at the age of twenties have participated as the subject group. The pulse has been measured twice at the three palpation positions, and by two-way repeated measures ANOVA we tested the repeatability and the mean differences in the aortic AIx between Chon, Gwan, and Cheok. The AIx was found to be statistically different between the measurement positions. Duncan's test shows that the AIx is statistically different between Chon and the other two positions. Our study may be used as a reference for further scientific quantification of the pulse diagnosis.

  • PDF

A Literature study on the Sasang Constitutional Tongue Diagnosis based on Experience Prescriptions(經驗方) in the Donguisusebowon (Longevity and Life Preservation in Oriental Medicine) (동의수세보원(東醫壽世保元) 경험방(經驗方)에 근거한 사상체질별 설진(舌診)의 문헌연구)

  • Lee, Jae-Chul;Kim, Jong-Yeol;Ryu, Hyun-Hee;Kim, Keun-Ho
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • 1. Objectives: This study was performed to research the relationship between Sasang Constitution and characteristics of tongue diagnosis based on Donguisusebowon's Experience prescriptions(經驗方). 2. Methods: We searched tongue diagnosis factors in Donguisusebowon and classified this. Based on Donguisusebowon's Experience prescriptions(經驗方), we find tongue diagnosis factors in 6 contemporary Oriental medicine prescription books. 3. Results: Most So-eumin has white thin tongue coating and clear redish tongue color. Yellow tongue coatings are found in symptoms for Yinjinho-tang(Yinchenhao-tang), Soseungki-tang(Xiaochengqi-tang), Daeseungki-tang(Dachengqi-tang). Shortened Tongue is found in So-eumin's experience prescription and So-yangin's treat histroy. It didn't shown that So-eumin's Semen Crotonis included 6 prescritions' factors of tongue diagnosis. So-yangin's white tongue coating is found in Hyungbangpaedok-san(Jingfangbaidu-san), Sipjo-tang(Shizao-tang), Sosiho-tang(Xiaocihu-tang), Shinki-hwan(Shenqi-wan). Most of other So-yangin's tongue coatings are Yellowish and tongue color is deep red. Tae-eumin have thin white tongue coating at the Mahuang-tang(Mahuang-tang). Red tongue color and drying tongue are found at Jowiseungki-tang(Tiaoweichengqi-tang)Daesiho-tang(Dacihu-tang)Saengmaek-san(Shengmai-san) 4. Conclusions: Following So-eumin's Experience prescriptions, So-eumin's tongue color is clear red and tongue coatings are thin white and greasy. Following So-yangin's Experience prescriptions, So-yangin's tongue color is deep red and tongue coatings are yellowish and scarce except Exterior cold disease. And So-yangin has specific symptom of irritability, oral sores. Tae-eumin's tongue has two sides of white thin tongue coatings and Red and drying tongue.

Study for Research Trends on Sasang Constitutional Medicine by Researchers in Other Fields (한의학계 외부의 사상체질의학에 관한 연구동향)

  • Lee, Soo-Jin
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.3
    • /
    • pp.67-74
    • /
    • 2010
  • 1. Objectives: The research papers published by researchers in other fields except Oriental medicine were analyzed to study the research trends and characteristic of Sasang Constitutional medicine. 2. Methods: Systematic searches were performed on KISS, RISS, KISTI and DBPIA and finally 123 papers were selected. The publication year, research field of the first author, title's characteristic, research topic and the classification method of Sasang Constitution were investigated. 3. Results and conclusions: 1) In the analysis of publication year, the number of studies on Sasang Constitution has increased dramatically since 2000. 2) In the analysis of the first author's research field, physical training, nursing, engineering and food and nutrition were the majority. 3) In the analysis of the research topic, the classification method of Sasang Constitution was the majority. 4) In the analysis of the classification method of Sasang Constitution, QSCC II was the most popular method accounted for 68% and interview by specialist of Sasang Constitutional medicine accounted for 42%.

Democratic Deepening and Constitutional Engineering in Thailand (태국 민주주의의 심화와 헌정공학)

  • KIM, Hong Koo
    • The Southeast Asian review
    • /
    • v.23 no.1
    • /
    • pp.45-87
    • /
    • 2013
  • This paper aims to study Thai democratic deepening and the constitutional engineering with the analytical concepts of 'power sharing' and 'accountability' focusing on the 1997 and 2007 Constitution. With regard to power sharing, the 1997 Constitution had the characteristics of majoritarian principle including a two-party system, strengthening of prime minister and the executive's power etc. It enhanced significantly the aspects of accountability compared with the previous constitutions. The institutions such as Constitutional Court, Commission on Election, Administration Court, Commission on Human Right, Ombudsman, Commission on Anti-corruption, and the Measure for Anti-money Laundering were established by the 1997 Constitution. However, such empowered accountability system were often abused by the political power groups in the political process. The 2007 Constitution has the characteristics of consensual principle including a multiparty system, proportional representation system, weakened prime minister's power, balancing of cabinet and parliament's power, pushing ahead with decentralization. However, the consensual principle of the 2007 Constitution came, in part, from the factional interests. It is similar to the 1997 Constitution in terms of accountability system, which enhanced in law but abused often in practice. One of the critical reasons for the failure of the 1997 and 2007 constitutions to consolidate democratic system was the political game played around the so-called network for the monarchy composed by the military, the civilian bureaucracy, Constitutional Court and the privileged classes. The future of the Thai democratic deepening depends on the constitutional engineering in which the factional interests should be excluded, and the rules of power sharing and accountability which traditionally played around the network for the monarchy should be effectively institutionalized.

Clinical Study of the Floating-Sinking Pulse Quantification Analysis on Ages, Left/Right, and Palpation Positions (20/60대 여성을 중심으로 살펴본 좌우 촌관척 부/침맥 정량화 임상연구)

  • Kim, Jae-Uk;Kim, Sung-Hun;Jeon, Young-Ju;Ryu, Hyun-Hee;Lee, Yu-Jung;Lee, Hae-Jung;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1193-1198
    • /
    • 2009
  • Pulse diagnosis is a central diagnosis method used in traditional Oriental medicine. To standardize and modernize the pulse diagnosis method, it is essential to develop an instrument-based reinterpretation of the clinically used pulse images in terms of the physical quantities such as the strength, period, width, length, and depth of the pulse. As a step towards such standardization, we conducted a clinical study on the floating/sinking pulses based on an automated palpation instrument (3D-MAC, Daeyo Medi, Korea) for 213 female subjects in their 20s and 174 female subjects in their 60s. The floating/sinking pulses are the two representative pulse images depending only on the depth of the pulse, and can be conveniently scaled by the coefficient of the floating-sinking pulse ($C_{fs}{\in}(0,1)$), which represents how strong one should apply the hold-down pressure to obtain the maximal pulse strength. As a result, primarily we found that it tends to appear more floating-like pulse ($C_{fs}{\rightarrow}0$) at Gwan and more sinking-like pulse ($C_{fs}{\rightarrow}1$) at Cheek, at both age groups and at both wrists. This result is consistent with a previous study on the geometrical structure of the blood vessel by an ultrasonograph. Second, the pulse tends to be more sinking-like in the age group of 60s than 20s. Finally, the pulses at the right palpation positions were found to be more sinking-like than the left, at both age groups.

A study for Oriental Medicine Pulse diagnosis of pulse wave analysis on left/right blood vessel (좌우 맥파분석을 통한 혈관특성 및 한의맥진연구)

  • Lee, Yu-Jung;Woo, Young-Jae;Lee, Hae-Jung;Jeon, Young-Ju;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1968_1969
    • /
    • 2009
  • 한의학에서 맥진을 하는 위치인 좌, 우 요골동맥상의 촌(寸), 관(關), 척(尺) 위치는 손목에 있는 요골 경상돌기(styloid preocess) 부근의 볼록한 지점인 고골(高骨)을 기준으로 맥이 느껴지는 위치를 검지, 중지, 약지를 이용해 찾는다. 각각의 위치는 한의학적인 관점에서 각기 다른 장부의 기능과 연결되며 그 차이를 인지하여 맥을 진단하는데 그 결과에 따라 병증을 진단하는 요소로 활용되게 된다. 그러나 생리학적으로 좌, 우 요골동맥의 차이는 크지 않다고 알려져 있으며 차이에 대한 연구도 많지 않다. 본 연구에서는 기존연구에서 밝혀진 좌, 우 요골동맥의 혈류속도의 차이를 근거로 한의사 맥진시 센서 역할을 하는 손가락에서 감지된 좌, 우 맥진위치의 차이가 실제 맥진기에서도 나타나는지를 측정을 통해 확인 해 보고자 한다. 건강한 20대 남자 135명을 대상으로 맥파를 측정하여 맥파 파라메터 중 차이를 보이는 파라메터를 통계분석하였다. 그 결과, 11개의 파라메터가 좌, 우 맥진위치에서 차이를 보이는 것을 확인하였다. 차이를 보이는 변수는 특정 변수로 한정되지 않고 맥압과 관련된 (h1~5) 변수와 피크가 나타나는 시간의 변수, 맥파 파형의 면적 등 다양한 변수에서 차이를 확인할 수 있었다.

  • PDF