• 제목/요약/키워드: Constant traction

검색결과 34건 처리시간 0.019초

전기기관차 견인전동기 운전점 특성과 가진주파수를 고려한 프레임 설계 (Frame Design Considering Exciting Frequency and Driving Characteristic of a Traction Motor for Electric Locomotive)

  • 김철수;김재문
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1759-1763
    • /
    • 2014
  • In this paper, we were performed a structural analysis and durability analysis for an integral frame with an axle according to development of the electric locomotive traction motor. In terms of the structural stability, as a result of the analysis modeling with coupling conditions of beam element and an alternative element of three-dimensional, the maximum von-Mises stress of the locking screw mounting frame were similar as 50MPa and 51MPa. Also A comparison of the natural frequency and the exciting frequency while driving of the electric locomotive No. 8200, the natural frequency is 627.05Hz~856.9Hz while the exciting frequency is not more than most 30Hz or 553Hz, 1110Hz. Therefore, it is possible to avoid the resonance.

한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구 (A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train)

  • 이상우;김근웅;윤종학;한성수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

철도 전력공급시스템에서의 고조파전류 확대현상에 관한 연구 (A Study on the Propagation of Harmonic Current in the Traction Power Supply System)

  • 오광해;창상훈;한문섭;이장무;신한순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.908-910
    • /
    • 1998
  • Modern AC electric car has PWM(Pulse Width Modulation) -controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit. As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current. The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF

철도 급전시스템에서의 고조파 해석 및 대책 연구 (A Study on the Countermeasures to Suppress Harmonics in the Traction Power Supply System)

  • 오광해;이장무;창상훈;한문섭;김길상
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.318-325
    • /
    • 1999
  • Modern AC electric car has PWM(Pulse Width Modulation)-controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit, As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF

하이브리드 자동차용 BLDC 전동기 제어 방법 (BLDC motor control method for hybrid electric vehicle)

  • 강신원;장종훈;정지예;원충연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.149-151
    • /
    • 2009
  • Hybrid electric vehicle has three operating mode, depending on the operation of the engine and electric motor. According to the speed range of BLDC motor, In hybrid traction mode, both the engine and electric motor deliver to drive train. Battery charge mode, the electric motor operates as generator and is driven by the engine to charge the batteries. In engine alone traction mode, the electric motor is do-energized, and vehicle is propelled by the engine alone. we propose hysteresis current control technique to maintain constant speed in the motor load torque at the reverse direction. The proposed method is verified by using Matlab Simulink software.

  • PDF

이종재 V-노치 균열의 대수응력특이성과 계수벡터에 관한 연구 (A Study on Logarithmic Stress Singularities and Coefficient Vectors for V-notched Cracks in Dissimilar Materials)

  • 조상봉;김우진
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.159-165
    • /
    • 2003
  • Most engineers interested in stress singularities have focused mainly on the research of power stress singularities for v-notched cracks in dissimilar materials. The logarithmic stress singularity was discussed a little in Bogy's paper. The power-logarithmic stress singularity was reported by Dempsey and Sinclair. It was indicated that the logarithmic singularity is only a special case of power-logarithmic stress singularities. Then, Dempsey reported specific cases which have power-logarithmic singularities even fur homogeneous boundary conditions. It was known that logarithmic stress singularities for v-notched cracks in dissimilar materials occurs when the surfaces of a v-notched crack have constant tractions. In this paper, using the complex potential method, the stresses and displacements having logarithmic stress singularities were obtained and the coefficients vectors were calculated by a numerical program code: Mathematica. It was shown that our analysis models don't have logarithmic stress singularities under the constant tractions, although the coefficient vectors are existing.

6단자망 회로모델을 이용한 전기철도 급전시스템의 고조파 해석 (Harmonic Analysis for Traction Power Supply System Using Four-Port Network Model)

  • 창상훈;오광혜;김주락;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.255-261
    • /
    • 2002
  • Recently, traction motors in trains are supplied with single phase a.c. power. After this power is converted to d.c. power, it is inverted to three phase power to operate traction motors. As going through the process of the conversion, harmonic current is generated in train. The method of conventional analysis on harmonics, studied by RTRI, is modeled with equivalent circuit of ac AT-fed electric railroad system using by the distributed constant circuit. However, this circuit as two-port network model has some difference in comparison with real system. The reason why the conventional method is different from the real system is that the conventional method dose not include three conductor groups, that is catenary, rail, and feeder, and admittance between the conductors for line capacitance. Therefore, this method has a little error. This paper proposes new method to more effectively estimate Harmonic current. In this method, numerous components in electric railway are categorized and each component is defined as a four- port network model. The equivalent circuit for the entire power supply system is also described into a four-port network model with connections of these components. In order to evaluate the efficiency and the accuracy of a proposed method, it is compared with values measured in Kyung-Bu high speed line and ones calculated by the conventional method.

전동기의 최대효율제어에 의한 전기자동차의 주행거리 증대 (The Traveling Distance Increase of Electric Vehicle with Maximum Efficiency Control of Traction Motor)

  • 박영우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2000
  • The purpose of this paper is to evaluate practical advantage in using maximizing efficiency control strategy in induction motor drives for electric vehicles. A maximizing efficiency control strategy consist of a flux estimation with direct field oriented controller is proposed and compared with the general constant flux control strategy. The comparison is carried out by experimental results and simulation of the behavior of electric vehicles. Results are included to show the effectiveness of the proposed strategy in the electric vehicle applications.

  • PDF

전차선 전압제약조건을 고려한 AT 급전계통 해석 (Analysis of AT Feeding Systems considering the Voltage Constraint Conditions of the Catenary.)

  • 김백;정광우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.27-33
    • /
    • 2005
  • Constant load model is generally used for an electric train to perform the static analysis of AT feeding systems. In this model, the train will be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. However there must be some voltage constraints on the catenary in actual operations. These constraints are established for the reason of protecting the feeding facilities from excessive rise of regenerative braking voltage or guaranteeing the minimum traction power of train. In normal operating situation, the pantagraph voltage of the train should be maintained within these limits. Keeping these facts in minds, we suggest new methods of analyzing AT feeding systems using the constant power models with the conditions of voltage constraints. The simulation results from a sample system using the proposed method illustrate both the states of system variables and the supply-demand relation of power among the trains and the systems very clearly, so it is believed that the proposed method yields more accurate results than conventional methods do. The proposed methods are believed to contribute to the assessment of TCR-TSC for compensating reactive powers too.

  • PDF

팬타그래프 전압제약조건을 고려한 AT급전계통 해석 (Analysis Of AT Feeding Systems Considering The Voltage Constraint Conditions Of The Pantagraph)

  • 문영현;김백
    • 한국철도학회논문집
    • /
    • 제9권6호
    • /
    • pp.652-656
    • /
    • 2006
  • Constant load model is widely used for an electric train to perform the static analysis of AT (Auto Transformer) feeding systems. In this model, the train will be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. However there must be some constraints imposed on the pantagraph voltage in actual operations. These constraints are established for the reason of protecting the feeding facilities from excessive rise of regenerative braking voltage or guaranteeing the minimum traction power of train. In normal operating situation, the pantagraph voltage of the train should be maintained within these limits. Keeping these facts in minds, we suggest new methods or analyzing AT feeding systems using the constant power models with the conditions of voltage constraints. The simulation results from a sample system using the proposed method illustrate both the states of system variables and the supply-demand relation of power among the trains and the systems very clearly, so it is believed that the proposed method yields more accurate results than conventional methods do. The proposed methods are believed to contribute to the assessment of TCR-TSC for compensating reactive powers too.