• 제목/요약/키워드: Constant current source

검색결과 252건 처리시간 0.029초

An Improved Control Approach for DSTATCOM with Distorted and Unbalanced AC Mains

  • Singh, Bhim;Solanki, Jitendra
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.131-140
    • /
    • 2008
  • This paper presents a new control approach of DSTATCOM (distribution static compensator) for compensation of reactive power, unbalanced loading and harmonic currents under unbalanced non-sinusoidal ac mains. The control of DSTATCOM is achieved using Adaline based current estimator based on LMS algorithm to maintain source currents real and undistorted. The dc bus voltage of voltage source converter (VSC) working as DSTATCOM is maintained at constant voltage using a proportional-integral (PI) controller. The DSTATCOM system alongwith proposed control scheme is modeled in MATLAB to simulate the behavior of the system. The practical implementation of the DSTATCOM is carried out using dSPACE DS1104 R&D controller having TMS320F240 as a slave DSP. Simulated and implementation results are presented to demonstrate the effectiveness of the DSTATCOM with Adaline based control to meet the severe load perturbations with different types of loads (linear and non-linear) under distorted and unbalanced AC mains.

DSP를 이용한 3상 태양광 인버터의 SPWM 전력변환기술에 대한 연구 (A Study on the SPWM based Power Conversion Technology of the Three-Phase Photovoltaic Inverter Using DSP)

  • 김효성;유호성;이유정;정훈;고윤석
    • 한국전자통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1099-1106
    • /
    • 2017
  • 본 논문에서는 신재생 에너지원인 태양광 발전을 위한 3상 인버터의 전력변환기술을 연구하였다. 태양광 인버터로는 정전압 공급 방식의 전압형 인버터, 제어기법으로는 SPWM 제어기법이 채택되었다. 태양광 인버터의 SPWM 제어기로는 강력한 고속 데이터 연산능력을 가지는 DSP가 채택되었으며, 배터리의 충전에 일정량의 전류를 공급하기 위해서 태양광 컨트롤러가 사용되었다. 끝으로, DSP를 주제어장치로 하는 소용량 3상 태양광 인버터 시스템이 시험, 제작되었으며, 실험을 통해서 SPWM 기반의 전력변환기능이 검증되었다.

ESL-𝚪-Z- Source Inverter

  • Pan, Lei;Sun, Hexu;Wang, Beibei;Dong, Yan;Gao, Rui
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.589-599
    • /
    • 2014
  • On the basis of the traditional ZSI (Z-source inverter), this paper presents a ESL-${\Gamma}$-ZSI, which uses a unique ${\Gamma}$-shaped impedance network and an extended SL network for boosting its output voltage in addition to their usual voltage-buck behavior. The inverter can increase the boost factor through adjusting shoot-through duty ratio and increasing the number of inductors. Capacitor voltage stress of ESL-${\Gamma}$-ZSI is a constant when 1>D>0, and ESL-${\Gamma}$-ZSI has small inductor current stress. The working principle of ESL-${\Gamma}$-ZSI and comparison with the classical ZSI and SL- ZSI are analyzed in detail. The power loss comparison between ESL-${\Gamma}$-ZSI and Cuk converter is analyzed detailedly. Simulation and experimental results are given to demonstrate the operation features of the inverter.

초고속 소형 BLDC의 순시 전압 제어에 의한 토크 리플 억제 (A Torque Ripple Reduction of Miniature BLDC using Instantaneous Voltage Control)

  • 이동희
    • 전력전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.191-198
    • /
    • 2007
  • 소형 BLDC(Brushless DC) 전동기는 높은 운전효율과 고토크 특성으로 인하여, 산업용 기계와 가전기기 및 특히 의료용 장비에 널리 사용되고 있다. 일반적인 BLDC 전동기의 경우에 전류(commutation) 구간에서의 토크 리플 억제에 대한 다양한 연구가 이루어져 왔다. 하지만, 초고속 BLDC 전동기의 경우 설계 특성상 전기적 시정수가 매우 짧아서 전류 구간에서의 토크 리플 보다 통전 구간에서의 토크 리플이 더 큰 영향을 미치게 된다. 본 논문에서는 40000rpm급 초고속 소형 BLDC 전동기의 전기적 시상수에 따른 통전구간에서의 토크리플을 해석하고, 토크 리플 억제를 위하여, 순시 전압 제어기와 고속 히스테리시스 전류 제어기를 제안한다. 제안된 순시 전압제어기는 통전구간에서의 토크 리플 억제를 위하여 운전속도와 부하전류에 적합한 전압을 순시적으로 제어하여 BLDC 전동기에 공급하고, 고속 히스테리시스 전류 제어기는 DSP의 지령전류에 따라, 제어 주기의 샘플링 지연없이 부하전류를 제어하는 시스템이다. 제안된 초고속 소형 BLDC 전동기의 토크 리플 억제를 위한 제어 시스템은 시뮬레이션 및 실험을 통하여 그 타당성을 증명하였다.

LED 광원에서 잡음 및 돌입전류 방지를 위한 스위칭모드 전원공급 장치 (SMPS) 개발 연구 (The Developed Study for SMPS to Protect the Noise and Inrush Current at LED Lighting Source)

  • 정찬수;홍규장;위성복;유건수;김미진
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.577-582
    • /
    • 2016
  • 최근 급속한 녹색환경 정책으로 LED를 이용한 조명 광원들이 설치 운용하고 있으나, 이들 광원의 전원 공급은 안정된 직류 전원 공급을 위해서 스위칭 모드 전원 공급(SMPS) 장치로 전원을 공급하고 있다. 그러나, 이들 전원 공급 장치는 공급 단가 때문에 설계 및 설치과정에서 스위칭에 따른 전력과 변환역률, 전기적 노이즈 및 돌입전류들은 간과하고 있다. 따라서, 본 연구에서는 SMPS는 고품질의 전원을 LED 조명 부하에 공급하기 위하여 스위칭 시에 다음과 같은 3가지 관점에서 회로를 연구하였다. 첫 번째, 역률과 효율을 약 85% 확보하고, 두 번째, 노이즈(고조파 포함) 최소화, 세 번째는 스위치-온 시 3A 돌입전류를 $100{\mu}sec$ 후 최소 0.3 A로 감소하여 돌입 전류 침입을 최소화 하고자 하였다. 본 연구에서는 IC형 구동기(LNK 409)를 적용하여 입력전압과 출력상황을 귀환 형태로 감시하도록 하였으며, 정전류 출력을 위하여 정전압을 유지할 수 있는 제어회로와 시상수를 개발하였다. 그러나, 부하 변동 시 미세한 전류의 불규칙으로 인한 발열 문제는 해결하지 못하고 있다. 이를 증명하고자 LED 조명 부하 46 W급을 대상으로 효과를 검증하였다.

Experimental Results of New Ion Source for Performance Test

  • 김태성;정승호;장두희;이광원;인상열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

마이크로 프로세서에 의한 영구자석동기 전동기의 구동 (Microprocessor Based Permanent Magnet Synchronous Motor Drive)

  • Yoon, Byung-Do
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.541-554
    • /
    • 1986
  • This paper presents the results of driving performance analysis of permanent magnet synchronous motor using a microprocessor based control system. The system consists of three phase power transistor inverters, three phase controlled rectifier, three central processing units, and sensors. The three CPUs are, respectively, used to generate PWM control signals for the inverter generating three phase sine wave, to generate the gate control signals for firing the converter, and to supervise other two CPUs. The supervisor is used to compute PI control algtorithm to three phase reference sine wave for the inverter. It is also used to maintain a constant voltage frequency ratio for the converter operating as a constant torque controller. The inverter CPU retrieves precomputed PWM patterns from look up tables because of computation speed limitations found in almost available microprocessors. The converter CPU also retrieves precomputed gate control patterns from another look-up tables. For protecting the control ststem from any damage by extraordinary over currents, the supervisor receives the data from current sensor, CT, and break down the CB to isolate the circuits from source. A resolver has a good performance characteristics of overall speed range, especially on low speed range. Therefor the speed control accuracy is impoved. The microprocessor based PM synchronous motor control system, thus, has many advantages such as constant torque characteristics, improvement of wave, limitation on extraordinary over currents, improvement of speed control accuracy, and fast response speed control using multi-CPU and look-up tables.

  • PDF

인입 전류에 따른 실리콘(Silicon) 다이오드의 극저온 p-n 접합의 문턱 전압 특성 (Properties of p-n junction threshold voltage of Silicon diode by transport current in cryogenic temperature)

  • 이안수;이승제;이응로;고태국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.864-867
    • /
    • 2003
  • Since the development of semiconductors, various related research has been conducted. During research, silicon diodes have been commonly used because of their simplicity and low cost in the manufacturing process. This research deals with p-n junction threshold voltages from silicon diodes due to transport current at a cryogenic temperature. At a cryogenic temperature(77K) we could get minimum current which junction threshold voltage becomes constant. This is experimented on GPIB communication and it consist of programmable current source, multimeter which gauge the threshold voltage in a very low temperature caused by transport current from 5nA to 1mA and $LN_2$(77K) for coolant. This experiment is programmed all process using Measurement studio(Lab window) tool.

  • PDF

Dielectric properties of Pr$_2$O$_3$ high-k films grown by metalorganic chemical vapor deposition on silicon

  • Nigro, Raffaella-Lo;Vito Raineri;Corrado Bongiomo
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제16권9호
    • /
    • pp.65.2-65
    • /
    • 2003
  • Praseodymium oxid ($Pr_2$$O_3$) thin films have been deposited on Si(100) substrates by metalorganic chemical vapor deposition using praseodymium tris-2,2,6,6-tetramethyl-3,5-heptandionate as source material. Film structural, morphological, and compositional characterizations have been carried out. Dielectric properties have been studied as well by capacitance-voltage and current-voltage measurements on metal-oxide-semiconductor capacitors of several areas. The $Pr_2$$O_3$ films have shown a dielectric constant = 23-25 and a leakage current density of $8.8{\times}10$-e $A/\textrm{mm}^2$ at +1 V.

  • PDF

고주파 발진형 근접 센서 시스템의 집적화를 위한 CMOS 회로 설계 (CMOS Circuit Designs for High Frequency Oscillation Proximity Sensor IC System)

  • 성정우;최평
    • 센서학회지
    • /
    • 제3권1호
    • /
    • pp.46-53
    • /
    • 1994
  • 본 논문에서는 FA용 센서 중의 하나인 고주파 발진형 근접 센서 시스템을 CMOS를 이용하여 설계하였다. 금속 물체의 원근에 따라 발생되는 크기가 다른 두 정현파를 전파정류부와 평활회로부를 통하여 DC 전압으로 전환하여 정전류회로의 출력단에 전류를 흐르게 한다. 슈미트 트리거를 사용하여 전압 레벨의 노이즈를 제거한다. 이를 통하여 고주파 발진형 근접 센서 시스템이 소형, 경량화, 저 소비 전력의 이점을 갖도록 하였다.

  • PDF