• Title/Summary/Keyword: Constant Current Controller

Search Result 217, Processing Time 0.027 seconds

Electronic Ballast with Constant Power Output Controller for 250W MH Lamp

  • Jung Dong-Youl;Park Jong-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.332-337
    • /
    • 2006
  • In this paper, an electronic ballast was developed to control a 250W metal halide lamp. To avoid acoustic resonance phenomenon, we calculated the acoustic resonance band and determined the driving frequency from 70kHz to 100kHz. Due to the switching loss of MOSFET, many problems are caused in the inverter circuit during lamp lighting, so we reduced the loss by connecting the capacitor that minimizes the magnitude of the impulsive voltage. In this paper, the main point of research is to find the methods to operate the lamp on the rated output power. After detecting the current and the voltage of the lamp, we changed the driving frequency by adjusting the DC voltage level of the VCO input.

Improved Direct Torque Control for Sensorless Matrix Converter Drives with Constant Switching Frequency and Torque Ripple Reduction

  • Lee Kyo-Beum;Blaabjerg Frede
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.113-123
    • /
    • 2006
  • In this paper, an improved direct torque control (DTC) method for sensorless matrix converter drives is proposed which enables to minimize torque ripple, to obtain unity input power factor, and to achieve good sensorless speed-control performance in the low speed operation, while maintaining constant switching frequency and fast torque dynamics. It is possible to combine the advantages of matrix converters with the advantages of the DTC strategy using space vector modulation and a flux deadbeat controller. To overcome the phase current distortion by the non-linearity of a matrix converter drive, the simple non-linearity compensation method using PQR power theory are presented in the proposed scheme. Experimental results are shown to illustrate the feasibility of the proposed strategy.

Single-stage Dimmable PFC DCM Flyback Converter without Electrolytic Capacitor (전해 커패시터를 제거하고 디밍이 가능한 고수명 단일단 PFC DCM 플라이백 컨버터)

  • Jin, Dal-Rae;Kim, Choon-Taek;Chae, Min-Cheol;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1550-1559
    • /
    • 2013
  • Light emitting diode(LED) lighting has been applied various industry fields because of its high efficiency, low power consumption, long life time, and environment friendly characteristics. Generally, LED lighting needs a driver to maintain constant current. Most popular driver is the switching converter. In the converter, there are several electrolytic capacitors. However the lifespan of the electrolytic capacitor is much shorter than LED. Therefore the lifespan of LED lighting with electrolytic capacitor is decreased. Also, LED lighting needs dimming control because of various needs and energy saving. This paper presents the dimmable single-stage PFC DCM flyback converter without electrolytic capacitor and parallel LC resonant filter for reducing 120[Hz] ripple on the output. The type 2 controller is used to maintain constant current and the analog dimming control is used. The proposed converter is verified through simulation and experimental works.

Simple Structure LED-Driving Power Converter with High Power Factor (높은 역률을 가지는 단순 구조 LED 구동 전력컨버터)

  • Jeong, Gang-Youl
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.767-773
    • /
    • 2018
  • This paper proposes the simple structure LED-driving power converter with high power factor. As the proposed power converter combines the PFC boost converter and the conventional flyback converter into only one power conversion circuit, it simplifies the structure of LED-driving power converter. Thus the proposed converter is controlled using only one PWM controller IC, and it achieves high power factor, constant output voltage/current and cost-effectiveness. Therefore the proposed converter is suitable for the industry production and utilization of LED-light-system. In this paper, the operation analysis and design example of the proposed converter are explained, briefly. Also experimental results of the prototype that is implemented based on the designed circuit parameters are shown to validate operation characteristics of the proposed converter.

Two Vector Based Direct Power Control of AC/DC Grid Connected Converters Using a Constant Switching Frequency

  • Mehdi, Adel;Reama, Abdellatif;Benalla, Hocine
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1363-1371
    • /
    • 2017
  • In this paper, an improved Direct Power Control (DPC) algorithm is presented for grid connected three phase PWM rectifiers. The new DPC approach is based on two main tasks. First the optimization of the look-up table, which is well-known in conventional DPC, is outlined for selecting the optimum converter output voltage vectors. Secondly a very simple and effective method is used to directly calculate their duty cycles from the power errors. Therefore, the measured active and reactive powers are made to track their references using hysteresis controllers. Then two vectors are selected and applied during one control cycle to minimize both the active and reactive power ripples. The main advantages of this method are that there is no need of linear current controllers, coordinates transformations or modulators. In addition, the control strategy is able to operate at constant switching frequencies to ease the design of the power converter and the AC harmonic filter. The control exhibits a good steady state performance and improves the dynamic response without any overshoot in the line current. Theoretical principles of the proposed method are discussed. Both simulation and experimental results are presented to verify the performance and effectiveness of this control scheme.

General Digital Fuzzy Logic Controller Design For Resonant Inverter (공진형 인버터를 위한 범용 퍼지 논리 제어기 설계)

  • 김태언;김남수;임영도
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.60-65
    • /
    • 2004
  • Induction heating system is time varying system around curie point. So, it has many troubles which are system shut down and change the load impedance. In this paper has been designed the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses and solve it's many troubles. The current full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy logic controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

A Novel MPPT Control of a Photovoltaic System using an FLC Algorithm

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.17-25
    • /
    • 2014
  • This paper proposes a novel maximum power point tracking (MPPT) system using a fuzzy logic control (FLC) algorithm for robust in-environment changing. The power available at the output of a photovoltaic (PV) cell continues to change with radiation and temperature because a solar cell exhibits nonlinear current-voltage characteristics. Therefore, the maximum power point (MPP) of PV cells varies with radiation and temperature. The MPPT methods are used in PV systems to make full utilization of the PV array output power, which depends on radiation and temperature. The conventional MPPT control methods such as constant voltage (CV), perturbation and observation (PO) and incremental conductance (IC) have been studied but these methods are problematic in that they fail to take into account the changing environment. The proposed FLC controller is based on the fuzzy control algorithm and facilitates robust control with the environmental changes. Also, the PV systems applied FLC controller is modeled by PSIM and the response characteristics of the FLC method according to environmental variations are analyzed through comparison with the performance of conventional methods. The validity of this controller is shown through response results.

A Solid State Controller for Self-Excited Induction Generator for Voltage Regulation, Harmonic Compensation and Load Balancing

  • Singh Bhim;Murthy S. S.;Gupta Sushma
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.109-119
    • /
    • 2005
  • This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self­excited induction generators (SEIGs) supplying balanced/unbalanced and linear/ non-linear loads. In practice, most of the loads are linear. But the presence of non-linear loads in some applications injects harmonics into the generating system. Because an SEIG is a weak isolated system, these harmonics have a great effect on its performance. Additionally, SEIG's offer poor voltage regulation and require an adjustable reactive power source to maintain a constant terminal voltage under a varying load. A three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC- VSI) known as STATCOM is used for harmonic elimination. It also provides the required reactive power an SEIG needs to maintain a constant terminal voltage under varying loads. A dynamic model of an SEIG-STATCOM system with the ability to simulate varying loads has been developed using a stationary d-q axes reference frame. This enables us to predict the behavior of the system under transient conditions. The simulated results show that by using a STATCOM based voltage regulator the SEIG terminal voltage can be maintained constant and free from harmonics under linear/non linear and balanced/unbalanced loads.

Microprocessor Based Permanent Magnet Synchronous Motor Drive (마이크로 프로세서에 의한 영구자석동기 전동기의 구동)

  • Yoon, Byung-Do
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.12
    • /
    • pp.541-554
    • /
    • 1986
  • This paper presents the results of driving performance analysis of permanent magnet synchronous motor using a microprocessor based control system. The system consists of three phase power transistor inverters, three phase controlled rectifier, three central processing units, and sensors. The three CPUs are, respectively, used to generate PWM control signals for the inverter generating three phase sine wave, to generate the gate control signals for firing the converter, and to supervise other two CPUs. The supervisor is used to compute PI control algtorithm to three phase reference sine wave for the inverter. It is also used to maintain a constant voltage frequency ratio for the converter operating as a constant torque controller. The inverter CPU retrieves precomputed PWM patterns from look up tables because of computation speed limitations found in almost available microprocessors. The converter CPU also retrieves precomputed gate control patterns from another look-up tables. For protecting the control ststem from any damage by extraordinary over currents, the supervisor receives the data from current sensor, CT, and break down the CB to isolate the circuits from source. A resolver has a good performance characteristics of overall speed range, especially on low speed range. Therefor the speed control accuracy is impoved. The microprocessor based PM synchronous motor control system, thus, has many advantages such as constant torque characteristics, improvement of wave, limitation on extraordinary over currents, improvement of speed control accuracy, and fast response speed control using multi-CPU and look-up tables.

  • PDF

Effect of Initial (Reference) Welding Current for Adaptive Control and It's Optimization to Secure Proper Weld Properties in Resistance Spot Welding

  • Ashadudzzaman, Md.;Choi, Il-Dong;Kim, Jae-Won;Nam, Dae-Geun;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.33 no.6
    • /
    • pp.13-20
    • /
    • 2015
  • Many automotive companies are endeavoring to improve the quality of resistance spot welding by updating body-in-white (BIW) production line with adaptive control spot welding system to compensate the process disturbances such as gap, electrode wear, oxidized surfaces, poor fit up and adhesive etc. Most of the commercial adaptive weld controllers require proper "Initial Welding Schedule" or "Reference weld" to achieve compensation in welding parameters during real time welding. In this study, the compensation of a commercial adaptive weld controller had been observed and analyzed thoroughly for various process disturbances to find optimal initial welding schedule. It was observed that 90 percent of the expulsion current in constant current control as reference welding schedule conferred the maximum button diameter in adaptive control welding. Finally, effects of each disturbance in combined field disturbances system with adaptive control had also been confirmed with the design of experiment (DOE) by minitab(R)16 for combined disturbances situation and suitability of optimum initial weld current had also established with real body part validation test.