• Title/Summary/Keyword: Constant Current

Search Result 2,611, Processing Time 0.027 seconds

Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(1) Stray Current Drainage System (직류전기철도 전식대책 실증실험(1) 누설전류 배류시스템)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Jeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.220-222
    • /
    • 2007
  • With the wide spread of direct current (DC) electric railroads in Korea, the stray currents or leakage currents from negative return rails become a pending problem to the safety of nearby underground infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). Although this method inherently possesses some drawbacks, its cost effectiveness and efficiency to protect the interfered structures has been the main reason for the wide adoption. In this paper, we show the field test results for the application of stray current drainage system to a city gas pipeline paralleling a depot area of a metropolitan rapid transit system. The process for optimal positioning is briefly illustrated. The effectiveness of constant voltage, constant current, and constant potential drainage schemes was also described.

  • PDF

Study of the Constant Current Fuzzy Control System Design using CRS Algorithm during Inverter DC Resistance Spot Welding Process (인버터 DC 저항점용접 공정에서 CRS 알고리즘을 이용한 정전류 퍼지 제어시스템 설계에 관한 연구)

  • Park, Hyoung-Jin;Park, Pyeong-Won;Yu, Ji-Young;Kim, Dong-Cheol;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.28 no.6
    • /
    • pp.76-83
    • /
    • 2010
  • The purpose of this study is to propose a method to decide near-optimal settings of the constant current fuzzy control parameters using a controlled random search. This method tries to find the near-optimal settings of the constant current fuzzy control parameters through experiments. It has an advantage of being able to carry out searches in the search domain which includes some irregular points. The method suggested in this study was used to determine the fuzzy control parameters by which the desired welding current were formed during inverter DC resistance spot welding. The output variable was the ITAE (integral of time multiplied by the absolute error). This output variable was determined according to the input variables, which are the GE, GDE, and GDU. This study described how to obtained near-optimal welding current condition over a wide search space conducting a relatively small number of experiments.

Dielectric properties with heat-input condition of PZT thin films for ULSI's capacitor -1- A study on the improvement of leakage current of PZT thin films using a amorphous PZT layer (초고집적회로의 커패시터용 PZT박막의 입열 조건에 따른 유전특성 -1- 비정질 PZT를 사용한 PZT 박막의 누설전류 개선에 관한 연구)

  • 마재평;백수현;황유상
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.101-107
    • /
    • 1995
  • To improve the leakage current, we developed two step sputtering method where PZT thin film in first deposited at room temperature followed by 600.deg. C deposition. The method used an amorphous PZT layer deposited at room temperature to keep a stable interface during sputtering at high temperature. PZT thin films were deposited on Pt/Ti/SiO$_{2}$/Si substrate at room temperature and 600.deg. C sequentially. The effect of the layer deposited at room temperature was investigated with regard to I-V characteristics and P-E hysteresis loop. In the case of the sample with the layer deposited at room temperature, both leakage current and dielectric constant were decreased. The thicker the layer deposited at room temperature was, the lower dielectric constant was. However, leakage current was indepenent of the variation of the thickness ratio. The sample with 200$\AA$ of the layer deposited at room temperature showed the most promising results in both dielectric constant and leakage current.

  • PDF

High-Efficiency Full-Bridge DC-DC Converter with Current-Doubler Rectifier with Asymmetric Pulse-Width Modulation (비대칭 펄스 폭 변조 방식의 배전류 정류기 회로를 적용한 고효율 풀-브릿지 DC-DC 컨버터)

  • Yang, Min-Kwon;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.280-289
    • /
    • 2015
  • A high-efficiency full-bridge DC-DC converter with a current-doubler rectifier and an asymmetric pulse-width modulation is proposed. Through the asymmetric pulse-width modulation, the proposed converter achieves zero-voltage switching of power switches without the circulating currents. The proposed converter reduces the output current ripple through the current-doubler rectifier. A control strategy is suggested for the proposed converter to charge battery banks. A constant current and constant voltage charging is performed. The proposed converter achieved a higher efficiency compared with the conventional full-bridge DC-DC converter with a phase-shift modulation. The performance of the proposed converter is evaluated by the experimental results for a 1.0 kW prototype circuit.

A Study on High Temperature Operation of SOI-MOSFET (SOI-MOSFET의 고온 동작에 관한 연구)

  • Choi, Chang-Yong;Moon, Kyung-Sook;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.706-710
    • /
    • 2008
  • The substrate bias effect on the current level of SOI-MOSFETs for high temperature operation has been investigated. In this work, we demonstrate the current level of SOI-MOSFETs can be controlled at different temperatures by applying a control bias to the substrate, showing that all current levels below T=150$^{\circ}C$ can be adjusted to a constant current level. 2D numerical simulation results show that substrate bias effectively controls the current conduction; as the substrate bias effectively lower the potential of the channel, inversion carrier generation is effectively controlled and consequently a constant current conduction level is achieved up to T=150$^{\circ}C$. We also demonstrate that the device simulated in this work has same operation at any temperature below T=150$^{\circ}C$ through mixed mode simulation.

Transient Phenomena in the Temperature rise of p-n Junctions (p-n Junction에서의 온도상승의 과도현상)

  • Lee, U-Il;Son, Byeong-Gi;Lee, Geon-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.4
    • /
    • pp.14-19
    • /
    • 1970
  • Transient phenomena in the p-n junction due to the selfheating effect of microplasma current have been investigated for the cases of small current and of large current. For the small current case, the temperature rise of the microplasma site is proportional to the current decrease and a unique time constant could be defined. However, the situation was complicated for the case of large current, and the time constant was not uniquely defined.

  • PDF

Energization method of Superconducting Magnet System with Persistent Current Mode (영구전류모드를 가지는 초전도 마그네트 시스템의 여자방법)

  • Ye, Jung-Hee;Nah, Wan-Soo;Joo, Jin-Ho;Hong, Gye-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.305-307
    • /
    • 1998
  • One of the merits of superconducting magnet system is that it has persistent current mode, in which the current can be constant without any external power supply. The problem is that when we energize the magnet we can not reach the target current with constant current source, in principle. It needs another energization methods, in which it can be energized with reasonable accuracy and time. This paper suggests two energization methods for a superconducting magnet with persistnet current mode and the comparisons of the two are made with respect to the accuracy and the time.

  • PDF

Large-Scale Current Source Development in Nuclear Power Plant (원전에 사용되는 직류전압제어 대전류원의 개발)

  • Jong-ho Kim;Gyu-shik Che
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.3
    • /
    • pp.348-355
    • /
    • 2024
  • A current source capable of stably supplying current as a measurement medium is required in order to measure and test important facilities that require large-scale measurement current, such as a control element drive mechanism control system(CEDMCS), in case of dismantling a nuclear power plant. However, it can provides only voltage power as a source, not current, although direct voltage controlled constant current source is essential to test major equipment. That kind of source is not available to supply stable constant current regardless of load variation. It is just voltage supplier. Developing current source is not easy other than voltage source. Very large-scale current source up to ampere class more than such ten times of normal current is inevitable to test above mentioned equipment. So, we developed large-scale current source which is controlled by input DC voltage and supplies constant stable current to object equipment according to this requirement. We measured and tested nuclear power plant equipment using given real site data for a long time and afforded long period load test, and then proved its validity and verification. The developed invetion will be used future installed important equipment measuring and testing.

Real time Compensation Algorithm of Rotor time Constant for Vector Controlled Induction Machine (백터제어 유도전동기의 회전자 시정수 실시간 보상 알고리즘)

  • Jeong, Jin-Uk;Kim, Jin-Kyu;Lee, Deuk-Kee;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1039-1041
    • /
    • 2000
  • To obtain a high performance in a vector controlled induction machine, it is essential to know the instantaneous position of the rotor flux which depends on the rotor time constant. But the rotor time constant mainly varies due to the temperature rise in the motor winding, so real time compensating algorithm is necessary. This paper proposes that it uses short duration pulses added to the constant flux command current and then resultant torque command current produced by speed controller is utilized for the rotor resistance estimation. This method has advantages with a low computational requirement and does not require voltage sensors. The proposed method is proved by simulations.

  • PDF