• Title/Summary/Keyword: Consonant loss profile

Search Result 3, Processing Time 0.017 seconds

A Relationship of Tone, Consonant, and Speech Perception in Audiological Diagnosis

  • Han, Woo-Jae;Allen, Jont B.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.298-308
    • /
    • 2012
  • This study was designed to examine the phoneme recognition errors of hearing-impaired (HI) listeners on a consonant-by-consonant basis, to show (1) how each HI ear perceives individual consonants differently and (2) how standard clinical measurements (i.e., using a tone and word) fail to predict these differences. Sixteen English consonant-vowel (CV) syllables of six signal-to-noise ratios in speech-weighted noise were presented at the most comfortable level for ears with mild-to-moderate sensorineural hearing loss. The findings were as follows: (1) individual HI listeners with a symmetrical pure-tone threshold showed different consonant-loss profiles (CLPs) (i.e., over a set of the 16 English consonants, the likelihood of misperceiving each consonant) in right and left ears. (2) A similar result was found across subjects. Paired ears of different HI individuals with identical pure-tone threshold presented different CLPs in one ear to the other. (3) Paired HI ears having the same averaged consonant score demonstrated completely different CLPs. We conclude that the standard clinical measurements are limited in their ability to predict the extent to which speech perception is degraded in HI ears, and thus they are a necessary, but not a sufficient measurement for HI speech perception. This suggests that the CV measurement would be a useful clinical tool.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • Korean Journal of Audiology
    • /
    • v.25 no.2
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.