• Title/Summary/Keyword: Conservation of mechanical energy

Search Result 185, Processing Time 0.025 seconds

Tuning Exothermic Curing Reaction of Hydrogenated Bisphenol A Epoxy Resins for Stone Conservation (석조문화재 보존.복원에 적용될 에폭시 수지의 경화 시 반응열 제어 및 안정성 향상 연구)

  • Choi, Yong-Seok;Park, You-Jin;Kang, Yong-Soo;Won, Jong-Ok;Kim, Jeong-Jin;Kim, Sa-Dug
    • Journal of Conservation Science
    • /
    • v.28 no.2
    • /
    • pp.131-139
    • /
    • 2012
  • The exothermic cure kinetics of epoxy resin was controlled by hardener containing fast and slow curing agents. The epoxy risen comprises hydrogenated bisphenol A-based epoxide (HBA), fast curing agent (FH) and slow curing agent poly(propyleneglycol)bis(2-aminopropylether) (SH). Talc was used as an inorganic additive. In the process of curing, cure kinetics along with temperature was monitored by differential scanning calorimeter (DSC) and thermocouple to show that the temperature increase was well controlled by adjusting the hardener mixture. Additionally, bending and tensile strengths of the epoxy/talc composites were also measured to be lower and higher with the amount of the talc inorganic additive, respectively. It is thus concluded that the increase in the temperature during exothermic curing reaction and mechanical properties of epoxy resins are tuned by optimizing hardener mixture for successful stone conservation.

A Dynamic Model of a Gas Engine-Driven Heat Pump in Cooling Mode for Real-Time Simulation

  • Shin, Young-Gy;Yang, Hoon-Cheul;Tae, Choon-Seob;Jang, Cheol-Yong;Cho, Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.85-93
    • /
    • 2006
  • The present study has been conducted to simulate dynamics of a gas engine-driven heat pump (GHP) for the design of control algorithm. The dynamic model of a GHP was based on conservation laws of mass and energy. For the control of refrigerant pressures, actuators such as an engine throttle valve, outdoor fans, coolant three-way valves and liquid injection valves were controlled by P or PI algorithm. The simulation results were found to be realistic enough to be applied for the control algorithm design. The model could be applied to build a virtual real-time GHP system so that it interfaces with a real controller for the purpose of developing control algorithm.

Estimate of package crack reliabilities on the various parameters using taguchi's method (다꾸찌방법을 사용한 여러변수들이 패키지균열에 미치는 신뢰도 평가)

  • Kwon, Yong-Su;Park, Sang-Sun;Park, Jae-Wan;Chai, Young-Suck;Choi, Sung-Ryul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.951-960
    • /
    • 1997
  • Package crack caused by the soldering process in the surface mounting plastic package is evaluated by applying the maximum energy release rate criterion. It could be shown that the crack propagation from the lower edge of the ie pad is easily occurred at the maximum temperature during the soldering process, where the pressure acting on the crack surface is assumed by the saturated vapor pressure at maximum temperature. The package crack formation depends on various parameters such as chip size, relative thickness, material properties, the moisture content and soldering temperature etc. The quantitative measure of the effects of the parameters could be easily obtained by using the taguchi's method which requires only a few kinds of combinations with such parameters. From the results, it could be obtained that the more significant parameters to effect the package reliability are the orders of Young's modulus, die pad size, down set, chip thickness and maximum soldering temperature.

Development on the M&V Protocol for DSM Investment Program (수요관리 투자사업의 성과검증(M&V)모형 개발)

  • Cho, Sung-Hwan;Choi, Bong-Ha;Kim, Euy-Kyung;Jeon, Ho-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.237-242
    • /
    • 2008
  • DSM(Demand Side Management) is reducing the load of energy supply utility through energy conservation and energy load distribution. This kind of program is necessary especially to our country which import above 97% of energy source. But the effectiveness of this kind program is not verified well even though our country is executing the various DSM programs. This study suggests M&V(Monitoring & Verification) guideline for DSM programs which are executing in Korea and shows the results which applied to verification of DSM programs.

  • PDF

PSYCHO-PHYSICS

  • Oh, Hung-Kuk
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.35-38
    • /
    • 2000
  • Conventional atom model must be criticized on the following four points.(1) natural motions between positive and negative entities are not circular motions but linear going and returning ones, for examples sexual motion, tidal motion, day and night etc.(2) Potential energy generation was neglected when electron changes its orbit from outer one to inner one. The hv is the kinetic energy of the photo-electron. The total energy difference between orbits comprises kinetic and potential energies. (3) The structure of the space must be taken into consideration because the properties of the electron do not changed during the transition from outer orbit to inner one even though it produces photon. (4) Total energy conservation law applies to the energy flow between mind and matter because we daily experiences a interconnection between mind and body.New atomic model 9the crystallizing $\pi$-bonding) was proposed in the journal of material processing technology since 1997 for the explanation of the mechanical behaviors in terms of physics. $\prod$-ray physics proved that the electrons can come out from in the nucleus and modern chemistry corresponds to the $\pi$-bonding by the nuclear electrons. The $\pi$-bonding structure of the protons outside the nucleus is that electrons move between protons of the different atoms. The perception step and the characteristic frequency in signal transduction is due to the accumulation of the $\pi$-rays outside of the proton before their absorption to the nucleus.

  • PDF

PSYCHO-PHYSICS

  • Oh, Hung-Kuk
    • Proceedings of the Korean Society for Cognitive Science Conference
    • /
    • 2000.05a
    • /
    • pp.71-75
    • /
    • 2000
  • Conventional atom model must be criticized on the following four points. (1) Natural motions between positive and negative entities are not circular motions but linear going and returning ones, for examples sexual motion, tidal motion, day and night etc. (2) Potential energy generation was neglected when electron changes its orbit from outer one to inner one. The hv is the Kinetic energy of the photo-electron. The total energy difference between orbits comprises kinetic and potential energies. (3) The structure of the space must be taken into consideration because the properties of the electron do not change during the transition form outer orbit to inner one even though it produces photon. (4) Total energy conservation law applies to the energy flow between mind and matter because we daily experiences a interconnection between mind and body. New atomic model (the crystallizing $\pi$-bonding) was proposed in the journal of material processing technology since 1997 for the explanation of the mechanical behaviors in terms of physics. $\prod$-ray physics proved that the electrons can come out from in the nucleus and modern chemistry corresponds to the $\pi$-bonding by the nuclear electrons. The $\pi$-bonding structure of the protons outside the nucleus is that electrons move between protons of the different atoms. The perception step and the characteristic frequency in signal transduction is due to the accumulation of the $\pi$-rays outside fo the proton before their absorption to the nucleus.

  • PDF

Control of the Absorption Air Conditioning System by Using Steepest Descent Method (최속 강하법을 이용한 흡수식 냉동공조시스템 제어)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.495-501
    • /
    • 2003
  • Control algorithms for the absorption air conditioning system may be developed by using dynamic models of the system. The simplified effective dynamic models, which can predict the dynamic behaviors of the system, may help to develop effective control algorithms for the system. In this study, control algorithms for an absorption air conditioning system were developed by using a dynamic simulation program. A cooling water inlet temperature control algorithm, a chilled water outlet temperature control algorithm, and a supply air temperature control algorithm, were developed and analyzed. The steepest descent method was used as an optimal algorithm. The simulation results showed energy savings and the effective controls of an absorption air conditioning system.

Numerical Analysis of an Arc Plasma in a DC Electric Furnace

  • Lee, Yeon-Won;Lee, Jong-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1251-1257
    • /
    • 2004
  • In order to analyze the heat transfer phenomena in the plasma flames, a mathematical model describing heat and fluid flow in an electric arc has been developed and used to predict heat transfer from the arc to the steel bath in a DC Electric Arc Furnace. The arc model takes the separate contributions to the heat transfer from each involved mechanism onto account, that is radiation, convection and energy transported by electrons. The finite volume method and a SIMPLE algorithm are used for solving the governing MHD equations, that are conservation equations of mass, momentum and energy together with the equations describing a standard k-${\varepsilon}$ model for turbulence. The model predicts heat transfer for different currents and arc lengths. Finally these calculation results can be used as a useful insight into plasma phenomena of the industrial-scale electric arc furnace. From these results, it can be concluded that higher arc current and longer arc length give high heat transfer

Two-Dimensional Analysis Model for Tapered Pulse Tubes (테이퍼를 갖는 맥동관의 2차원 해석모델)

  • Baek, Sang-Ho;Jeong, Eun-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.668-676
    • /
    • 2000
  • A two-dimensional model for pulse tubes with tapered cross-section was proposed. Net enthalpy flow and steady mass streaming were investigated by two-dimensional analysis of mass, momentum and energy equations of the gas as well as energy conservation of the tube wall. Steady mass flux profiles show good agreement with the previous approximate solution. It was shown that steady mass streaming can be reduced by tapering a pulse tube and by increasing the length of a pulse tube. Effects of the velocity phase angle and frequency on steady mass streaming were shown.

Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System (복합 열원 공조시스템의 최적 제어 알고리즘)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.