• Title/Summary/Keyword: Connector

Search Result 835, Processing Time 0.033 seconds

Highly Accelerated Life Tests for Auto-Connector in Use-Environment (자동차 환경을 고려한 커넥터의 가속시험에 관한 연구)

  • Kim Jong-Gurl;Kim Jin-Hawn
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.229-235
    • /
    • 2004
  • This paper treats accelerated life tests for automotive connector. The contact resistance of connector is explained by some factors; the use time(calender time, real cycle), stresses and loads adapted in auto test. The relationships between contact resistance and some factors are compared and analyzed by regression models in various test conditions; field use-environment, manufacturer's test environment, and accelerated test condition. The consistency between of manufacturer's test and field test is examined. Finally, the future study on accelerated test for automotive connector is presented.

  • PDF

Active Damping of an Electric Connector with Piezoelectric Materials (압전 재료를 이용한 전기 차단기의 능동제진)

  • 노용래
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.92-97
    • /
    • 1992
  • Undesired vibratory motion of an electric connector is controlled in an active method with piezoelectric sensors and actuators. A special electric control box is developed which is suitable for the purpose. Experimental results show that the system can effectively reduce amplitude responses connector to external forces.

  • PDF

Investigation of natural modes of moduled floating structure considering connector stiffness (모듈형 부유구조물의 커넥터 강도에 따른 고유모드 고찰)

  • Kim, Byoung-Wan;Hong, Sa-Young;Kyoung, Jo-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.348-351
    • /
    • 2007
  • This paper investigates the natural modes of moduled floating structure with module unit connector. As an example structure, a floating parking place($120m{\times}60m$) is considered. In the evaluation of natural modes, numerical equations are formulated by FEM(Finite Element Method) and the natural modes are solved by the subspace iteration method. By comparing results for various stiffness of module unit connector, the effect of stiffness of unit connector is examined.

  • PDF

Investigation of Natural Modes of Moduled Floating Structure Considering Unit Size and Connector Stiffness (모듈형 부유구조물의 유닛 크기 및 커넥터 강도에 따른 고유모드 고찰)

  • Kim, Byoung-Wan;Hong, Sa-Young;Kyoung, Jo-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.356-360
    • /
    • 2008
  • This paper investigates the natural modes of moduled floating structure with module unit connector. As an example structure, a floating parking place($120m\;{\times}\;60m$) is considered. In the evaluation of natural modes, numerical equations are formulated by FEM(finite element method) and the natural modes are solved by the subspace iteration method. By comparing results for various sizes of module unit, the effect of unit size is investigated. By comparing results for various stiffness of module unit connector, the effect of stiffness of unit connector is also examined.

Design of Variable Power Distributor and Waveguide Connecting Structure for Wireless Microwave Power Transmission in a Building (실내 마이크로파 배전 전송계를 위한 가변전력분배기와 도파관의 결합구조 설계)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1477-1482
    • /
    • 2012
  • This paper deals with a new variable microwave power distributor and a connector between a deck plate and a input power waveguide for indoor microwave wireless power transmission. We design a new type connector built in the 3-stage coaxial line structure, and calculate the return loss of the connector at 2.45GHz. Newly designed connector shows the excellent return loss performance less than -30dB at the operating frequency of 2.45GHz. And we show a power distributor in which the dividing ratio of the power is controlled mechanically by three rotary fins. The distributor can control the dividing power from 4.5% to 58% with the variance of 5% output power. The experimentally tested results of the distributor are good agreement with the simulation within the return loss of 1%.

A Study of Bridge Connector Development on Wiring Harness Improvement in Vehicles (차량용 와이어링 하네스 개선을 위한 브릿지 커넥터 개발에 관한 연구)

  • Ryu, Su-uk;Park, Kyoung-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.66-72
    • /
    • 2010
  • Recently a large number of electronic control devices are abruptly increasing in vehicles as the electronic industry advances. Also the number of wiring harnesses and complexity of wiring is proportionally increased to the devices. A newly developed connector named bridge connector is introduced in this study for the purpose of the wiring structure changes. A wiring structure among distributed control systems by using serial communication is proposed with the bridge connector in this paper. The bridge connector contains a auto-recovery fuse made by PTC thermistor material for the protection of the over-currents on local control devices. The auto-recovery function of the fuse is needed for the maintenance free system in the distributed controls. The PTC fuse characteristics organized in this study is tested and the results are showed in detail for the real application.

Root cause analysis on the phenomenon of voltage drop of connector used in the automotive throttle body control (스로틀 바디 제어신호 전달용 커넥터의 이상전압 강하 현상 원인 규명)

  • Cho, Young-Jin;Chang, Seog-Weon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1792-1797
    • /
    • 2007
  • This paper try to find root-cause of failure in a connector used in transmitting signals for throttle body control in automotives by analyzing possible failure causes and performing experiments to simulate the cable failure in field. The connector comprises fins, wires, and case moldings. The failure is due to degradation of initial clamping force required fixing fins and wires in the connector. Expansion and compression of the case molding material surrounding fins would cause the degradation. Investigations of strict initial claming force and control of thermal expansion property of the molding are required to prevent the failure.

  • PDF

The question at issue of connector wire in High Speed Railway Catenary System of France (프랑스 고속철도 전차선로 시스템에서 균압선의 문제점)

  • 안영훈
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.636-651
    • /
    • 2000
  • In these days, SNCF replace the connector wire (M-T type) with a dropper has a equivalent role and function of the one in general lines of TGV, and change the connector wire (T-T-M-M-T-T, T-T-M-M-T type, etc) into a New one has more flexible cable in parallel lines (air section air joint, etc) of TGV. The Connector wire has many problems according to a flow of excessive circulation current (or traction current) and a sudden rise of temperature on catenary when electric locomotive is running in high speed. To solve the question at issue of the connector wire in high speed railway catenary system of Fiance, SNCF return their operating experience in TGV lines to design and execution of catenary system Therefore, we have to deal with the question in design and execution of catenary system for kyoungbu HSR line because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

Connector Design and Automatic Creation for Components Assembly (컴포넌트 조립을 위한 커넥터 설계 및 자동 생성)

  • Han Jung-Soo;Chae Eun-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.2
    • /
    • pp.275-281
    • /
    • 2005
  • In view of component based development, system development has replaced by assembling existent software components instead of coding and now component assembly research has progressed. In this paper, we formalized the specification using relationship between components for component assembly. If components are assembled through connector, the assembly is available without method call or modification. Therefore in this paper, we formalized the specification and constraint condition for creation of connector which connects components so that the connector is created automatically through the specification and constraint condition.

  • PDF

Effects of Design Variables on Compression Rate of Wire in Connector Crimping Process of Wire Harness Using FEM (와이어 하네스의 압착공정에서 설계변수가 압축률에 미치는 영향 연구)

  • Gu, S.M.;Choi, H.S.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.5
    • /
    • pp.305-310
    • /
    • 2010
  • Recently industry of motor vehicle is making a gradual progress of automotive electric components. According to this step, wire harness equipped at motor vehicle is also increased. The most important component at the wire harness is electric connector. At the manufacturing process of electric connector, exactly at the crimping process, design variables, such as clamping-height, clamping-width and clamping die shape are critical parameters to assure satisfactory harness shape in clamping process of electric connector. In this study we have performed FEM simulation for clamping process and clarified the effect of design variables on compression rate of wire.