• 제목/요약/키워드: Connection rotation capacity

검색결과 79건 처리시간 0.022초

Evaluation of Three Support Shapes on Behavior of New Bolted Connection BBCC in Modularized Prefabricated Steel Structures

  • Naserabad, Alifazl Azizi;Ghasemi, Mohammad Reza;Shabakhty, Naser;Arab, Hammed Ghohani
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1639-1653
    • /
    • 2018
  • Bolted connections are suitable due to high quality prefabrication in the factory and erection in the workplace. Prefabrication and modularization cause high speed of erection and fabrication, high quality and quick return of investment. Their technical hitches transportation can be removed by prefabrication of joints and small fabrication of components. Box-columns are suitable members for bolted structures such as welded steel structures with moment frames in two directions etc., but their continual fabrication in multi-story buildings and performing the internal continuity plate in them will cause some practical dilemmas. The details of the proposal technique introduced here, is to remove such problems from the box columns. Besides, some other advantages include new prefabricated bolted beam-to-column connections referred to BBCC. This connection is a set of plates joined to columns, beams, support, and bolts. For a better understanding of its fabrication and erection techniques, two connection and one structural maquettes are made. The present work aims to study the cyclic behavior of connection numerically. To verify the accuracy of model, a similar tested connection was modelled. Its verification was then made through comparison with test results. The behavior of connection was evaluated for an exterior connection using three different support shapes. The effects of support shapes on rigidity, ductility, rotation capacity, maximum strength, four rad rotation strength were compared to those of the AISC seismic provision requirements. It was found that single beams support has all the AISC seismic provision requirements for special moment frames with and without a continuity plate, and box with continuity plate is the best support in the BBCC connection.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

개선된 엑세스 홀 형상을 갖는 WUF-W접합부의 실험을 통한 내진성능평가 (Experimental Evalutation of the Seismic Performance of WUF-W Moment Connections with a Modified Access Hole)

  • 한상환;정진;문기훈;김진원
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.21-28
    • /
    • 2012
  • Welded Unreinforced Flange-Welded Web (WUF-W) connection is one of Special Moment Frame (SMF) specified in ANSI/AISC-358. From the experimental test of WUF-W connection specimens conducted by the previous study, fracture occurred in the beam flange before achieving total inter-story drift angle of 0.04radian required for Special Moment Frames (SMF) system even though the specimens satisfied the design and detailing requirement specified in ANSI/AISC-358. These results are estimated as problem of the access hole geometry. In this study, a full-scale WUF-W connection specimen was made with a modified access hole geometry, and tested with the same test setting and loading as the previous test. From test results, the deformation capacity of the tested WUF-W connection specimen exceeded 4%, which is required for connections in SMF system. Comparing with the WUF-W specimens of the previous study, the strain demand of the beam flange in the tested specimen was decreased and energy dissipation capacity of the specimen was improved.

상·하부 ㄱ형강 반강접 CFT 기둥-보 접합부의 단조 및 이력거동 (Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Top-Seat Angle)

  • 이성주;김주우
    • 한국강구조학회 논문집
    • /
    • 제26권3호
    • /
    • pp.191-204
    • /
    • 2014
  • 본 논문에서는 반복하중을 받는 CFT 합성골조에서 부분강접 접합부인 상 하부 ㄱ형강 접합부의 휨모멘트 내력을 구하기 위하여 체계적인 수치해석이 수행되었다. 고강도강 연결봉으로 조립된 합성 부분강접 CFT 접합부의 회전강성, 휨모멘트 내력 및 파괴모드를 연구하기 위하여 3차원 비선형 유한요소 해석이 수행되었다. 부가적인 다양한 구조적 거동은 ㄱ형강의 두께 및 고강도 강봉 게이지 거리로 상 하부 ㄱ형강 접합의 파라미터에 대한 영향을 설명하고 있다. 해석모델의 적합성은 유한요소해석 결과로부터 얻은 모멘트-회전각 곡선을 Richard의 회귀분석을 통하여 비교 분석하였다.

전단력을 받는 더블 앵글 접합부의 비선형 거동에 관한 해석적 연구 (An Analytical Study on the Nonlinear Behavior of Double Angle Connections Subjected to Shear)

  • 이수권;홍갑표
    • 한국강구조학회 논문집
    • /
    • 제12권1호통권44호
    • /
    • pp.65-73
    • /
    • 2000
  • 상용 유한요소해석 프로그램인 ABAQUS(ver5.8)를 이용하여 전단력을 받는 더블앵글 접합부의 3D 해석을 수행하여 접합부의 모멘트-회전 관계곡선을 구하고 앵글과 볼트의 응력분포를 관찰한다. 해석시 주요 매개변수로는 볼트수, 게이지거리, 앵글의 두께로 하였으며 유한요소해석 결과로 구한 모멘트-회전곡선을 Richard가 제시한 예측식에 적용한 후 회귀분석을 통하여 접합부 거동을 예측하는 데 필요한 매개변수인 초기강성, 소성강성, 참조모멘트, 곡선형태변수를 구한다. 또한 매개변수들이 게이지거리, 앵글의 두께 및 볼트 수 변화에 따른 그래프를 작성하고 또한 이 그래프를 이용하여 접합부의 모멘트 및 LRFD의 접합부 분류에 따른 소성모멘트에 대한 접합부 모멘트의 비를 계산한다.

  • PDF

Strength upgrading of steel storage rack frames in the down-aisle direction

  • El Kadi, Bassel;Cosgun, Cumhur;Mangir, Atakan;Kiymaz, Guven
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.143-152
    • /
    • 2017
  • This paper focuses on the seismic performance of pallet-type steel storage rack structures in their down aisle direction. As evidenced by experimental research, the seismic response of storage racks in the down-aisle direction is strongly affected by the nonlinear moment-rotation response of the beam-to-column connections. In their down-aisle direction, rack structures are designed to resist lateral seismic loads with typical moment frames utilizing proprietary beam-to-column moment-resisting connections. These connections are mostly boltless hooked type connections and they exhibit significantly large rotations resulting in large lateral frame displacements when subjected to strong ground motions. In this paper, typical hooked boltless beam-to-column connections are studied experimentally to obtain their non-linear reversed cyclic moment-rotation response. Additionally, a compound type connection involving the standard hooks and additional bolts were also tested under similar conditions. The simple introduction of the additional bolts within the hooked connection is considered to be a practical way of structural upgrade in the connection. The experimentally evaluated characteristics of the connections are compared in terms of some important performance indicators such as maximum moment and rotation capacity, change in stiffness and accumulated energy levels within the cyclic loading protocol. Finally, the obtained characteristics were used to carry out seismic performance assessment of rack frames incorporating the tested beam-to-column connections. The assessment involves a displacement based approach that utilizes a simple analytical model that captures the seismic behavior of racks in their down-aisle direction. The results of the study indicate that the proposed method of upgrading appears to be a very practical and effective way of increasing the seismic performance of hooked connections and hence the rack frames in their down-aisle direction.

Numerical analysis of the mechanical behavior of welded I beam-to-RHS column connections

  • Rosa, Rosicley J.R.;Neto, Juliano G.R.
    • Coupled systems mechanics
    • /
    • 제8권2호
    • /
    • pp.185-197
    • /
    • 2019
  • Considering the increasing use of tubular profiles in civil construction, this paper highlights the study on the behavior of welded connections between square hollow section column and I-beam, with emphasis on the assessment of the joint stiffness. Firstly, a theoretical analysis of the welded joints has been done focusing on prescriptions of the technical literature for the types of geometries mentioned. Then, a numerical analysis of the proposed joints were performed by the finite element method (FEM) with the software ANSYS 16.0. In this study, two models were evaluated for different parameters, such as the thickness of the cross section of the column and the sizes of cross section of the beams. The first model describes a connection in which one beam is connected to the column in a unique bending plane, while the second model describes a connection of two beams to the column in two bending planes. From the numerical results, the bending moment-rotation ($M-{\varphi}$) curve was plotted in order to determine the resistant bending moment and classify each connection according to its rotational capacity. Furthermore, an equation was established with the aim of estimating the rotational stiffness of welded I beam-to-RHS column connections, which can be used during the structure design. The results show that most of the connections are semi-rigid, highlighting the importance of considering the stiffness of the connections in the structure design.

Investigation on the monotonic behavior of the steel rack upright-beam column connection

  • Cao, Yan;Alyousef, Rayed;Jermsittiparsert, Kittisak;Ho, Lanh Si;Alaskar, Abdulaziz;Alabduljabbar, Hisham;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.103-115
    • /
    • 2020
  • The cold-formed steel storage racks are extensively employed in various industries applications such as storing products in reliable places and storehouses before distribution to the market. Racking systems lose their stability under lateral loads, such as seismic actions due to the slenderness of elements and low ductility. This justifies a need for more investigation on methods to improve their behavior and increase their capacity to survive medium to severe loads. A standardized connection could be obtained through investigation on the moment resistance, value of original rotational stiffness, ductility, and failure mode of the connection. A total of six monotonic tests were carried out to determine the behavior of the connection of straight 2.0 mm, and 2.6 mm thickness connects to 5 lug end connectors. Then, the obtained results are benched mark as the original data. Furthermore, an extreme learning machine (ELM) technique has been employed to verify and predict both moment and rotation results. Out of 4 connections, increase the ultimate moment resistance of connection by 13% and 18% for 2.0 mm and 2.6 mm upright connection, respectively.

비보강 확장단부판 접합부의 에너지소산능력 평가 (Evaluation of the Energy Dissipation Capacity of an Unstiffened Extended End-plate Connection)

  • 이수권;양재근
    • 한국강구조학회 논문집
    • /
    • 제27권2호
    • /
    • pp.243-250
    • /
    • 2015
  • 확장단부판(extended end-plate) 접합부는 보-기둥 모멘트 접합부의 한 형태로 접합부를 구성하는 단부판(end-plate)의 두께 및 길이, 고장력볼트의 개수 및 직경, 고장력볼트의 게이지 거리, 용접부의 치수 및 길이 등에 따라서 상이한 거동특성과 에너지소산능력을 발현한다. 이러한 확장단부판(extended end-plate)는 미국 및 유럽 등지에서는 다양한 기하학적 형상으로 기둥-보 접합부에 적용되고 있다. 그러나 현재 우리나라에서는 강구조 보-기둥 접합부에 적극적으로 적용되고 있지 못한 상황이다. 이렇게 적용성이 높지 않은 이유로는 기하학적 형상변화에 따른 설계강도식 제안, 에너지소산능력 평가 및 시공지침의 제공이 적절하게 이루어지지 못하고 있기 때문이다. 따라서 이 연구에서는 단부판(end-plate) 두께가 상대적으로 얇은 기하학적 형상을 갖는 비보강 확장단부판(unstiffened extended end-plate) 접합부의 에너지소산능력을 평가하여 에너지소산능력 예측모델을 제안하기 위한 기초자료를 제공하기 위하여 진행하였다. 이를 위하여 비보강 확장단부판(unstiffened extended end-plate) 접합부에 대한 3차원 비선형 유한요소해석을 단부판(end-plate)의 두께를 변수로 하여 수행하였다.

패널존 강도 및 보 웨브 접합방식이 RBS 철골 모멘트접합부의 내진거동에 미치는 영향에 관한 연구 (Cyclic Seismic Performance of Reduced Beam Section Steel Moment Connections: Effects of Panel Zone Strength and Beam Web Connection Type)

  • 이철호;전상우;김진호
    • 한국지진공학회논문집
    • /
    • 제7권3호
    • /
    • pp.69-77
    • /
    • 2003
  • 본 연구는 8개의 RBS(reduced beam section) 내진 철골모멘트접합부의 실물대 실험결과를 요약한 것이다. 실험의 주요변수는 보 웨브 접합법 및 패널존 강도를 택하였다. 균형 패널존 시험체는 접합부의 내진성능을 감소시키지 않으면서, 보와 패널존이 함께 균형적으로 지진에너지를 소산시키도록 설계하여 값비싼 패널존 보강판(doubler plates)의 수요를 줄이고자 시도한 것이다. 보 웨브를 용접한 시험제는 모두 특별 연성모멘트골조에서 요구되는 접합부 회전능력을 충분히 발휘하였다. 반면 보 웨브를 볼트 접합한 시험체는 조기에 스캘럽을 가로지르는 취성파단이 발생하는 열등한 성능을 보였다. 보 그루브 용접부 자체의 취성파괴가 본 연구에서와 같이 양질의 용접에 의해 방지되면, 스켈럽 부근의 취성파단이 다음에 해결해야 할 문제로 대두되는 경향을 보인다. 보 웨브를 볼팅한 경우에 접합부 취성파단의 빈도가 월등히 높은 이유를 실험 및 해석결과를 토대로 제시하였다. 측정된 변형도 데이터에 의할 때, 접합부의 전단력 전달메카니즘은 흔히 가정하는 고전 휨이론에 의한 예측과 전혀 다르다. 이는 전통적 보 웨브 설계법을 재검토할 필요가 있음을 시사하는 것이다. 아울러, 접합부에서 요구되는 바람직한 거동기준을 제시하고 이를 근거로 균형 패널존의 강도범위에 대한 예비적 추정치를 제시하였다.