A STUDY OF PHOTOELASTIC STRESS ANALYSIS IN THE IMZ IMPLANT-NATURAL 700TH SUPPORTED FIXED PARTIAL DENTURE USING ATTACHMENT WITH OR WITHOUT RIGID CONNECTION (어태치먼트를 이용한 IMZ 임플랜트와 자연치의 연결시 고정유무의 연결형태에 따른 광탄성 응력분석에 관한 연구)

  • Kim, Jeong-Sun;Hwang, Young-Phil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.130-143
    • /
    • 1995
  • The purpose of this study was to analyze the magnitude and distribution of stress using photoelastic model with the rigid connection using T-block attachment and non-rigid connection using key & keyway attachment. The vertical load of 16 Kg was applied on the central fossa of the tooth, the pontic and the implant, and the pattern and distribution under each condition was analyzed. The following results were obtained : 1. In case of vertical load on the central fossa of the implant, the stress was concentrated at the apex of the implant involving the mesial alveolar bone in both fixed partial denture with the rigid connection and that with the nonrigid connection and the stress concentration at the mesial cervical area of the implant was a little more in the nonrigid connection than in the rigid connection. 2. In case of vertical load on the central fossa of the pontic, the stress was concentrated at the apex of 2nd bicuspid in both 3 unit fixed partial denture with nonrigid connection and that with the rigid connection. The stress was more concentrated at the mesial alveolar bone of the implant, but the stress distribution at the natural teeth more favorable at the rigid connection than at the non-rigid connection in case of 4 unit fixed partial denture. 3. In case of vertical load of the central fossa of the 2nd bicuspid, much stress with 3 fringe order was observed at the apex of the 2nd bicuspid in the 3 unit fixed partial denture, but relatively even stress distribution was observed at the apex of the implant, the 1st and 2nd bicuspid, and the adjacent cuspid in the 4 unit fixed partial denture.

  • PDF

An Alternative Unit Root Test Statistic Based on Least Squares Estimator

  • Shin, Key-Il
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.3
    • /
    • pp.639-647
    • /
    • 2002
  • Efforts to obtain more power for unit root tests have continued. Pantula at el.(1994) compared empirical powers of several unit root test statistics and addressed that the weighted symmetric estimator(WSE) and the unconditional maximum likelihood estimator(UMLE) are the best among them. One can easily see that the powers of these two statistics are almost the same. In this paper we explain a connection between WSE and UMLE and suggest a unit root test statistic which may explain the connection between them.

Development of Launch Vehicle Connection Unit and High Pressure Flexible Hose for KSLV-II Ground Operation (우주센터 종합조립동 고압가스 운용을 위한 발사체 접속장치 및 고압유연배관 개발)

  • Nam, Jungwon;Chun, Young-Doo;Jang, Youngsoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1156-1159
    • /
    • 2017
  • The various ground support equipments are necessary for KSLV-II ground operation at the assembly building located in Naro Space Center. Among the various ground support equipments, the launch vehicle connection unit and high pressure flexible hose are important elements, because they are used for connection between the ground compressed gas supply system and the launch vehicle. In this paper, the development progress of the launch vehicle connection unit and high pressure flexible hose are introduced.

  • PDF

Test Result on Embedded Steel Column-to-Foundation Connection for Modular Unit Structural System (유닛 모듈러 기둥 매입형 기초 접합부에 대한 실험 연구)

  • Lee, Sang Sup;Bae, Kyu Woong;Park, Keum Sung;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.537-547
    • /
    • 2014
  • A steel modular unit structural system has been used increasingly for mid and high-rise buildings, since the building can be easily constructed by assembling the pre-made modular unit structures. For this structural system, each modular unit structures have to be properly connected to the foundation to transfer the axial force and the bending moment that are generated from external load to the ground. In this study, a new type of the embedded steel column-to-foundation connection was proposed, and its flexural behavior was evaluated through a series of experimental study. Five full scale specimens for the proposed connections were constructed and tested. The effect of the main parameters that affect the flexural behavior of the proposed connection, such as embedment length and shape of end plate, were studied. From the results, it was found that the flexural stiffness of the proposed connection was higher than that of the semi-rigid connection for all test specimens, and 200 mm of embedment length was proper for the given test specimens in this study.

Analysis for Thermal Effect by an Unheated Housing Unit in Apartment (공동주택에서 비난방세대가 미치는 열적 영향)

  • Lee, Eun-Ju;Koo, Junemo;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.

A Study on Patterns of Spatial Connection and Visitor's Circulation Path in Museum Exhibition Space (박물관 단위전시실의 공간연결패턴에 따른 관람객 동선특성에 관한 연구)

  • Choi Jun-Hyuck
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.155-162
    • /
    • 2006
  • Space is integrated or segment with organic formation by circulation path. It estimates important problem to grasp as factor that promote movement of visitor and space organization without grasping circulation as connection relation about simple space function from these viewpoint, is a thing which this study does not cause confusion to visitor's circulation path through data that analyze form of space connection and visitor's circulation path as quantitative in museum space and layout form that access by easy each unit exhibition grasps what it is. This study does factor grasping for guideline and inspection circulation path of layout by purpose in exhibition space on the basis of analytical result that grasps connection form between exhibition area that grasp laying stress on visitor's movement and appears in space through follow-up survey for circulation path of museum exhibition area. Space connection form that is expose by sequence of investigation and analysis(II) estimates on constituent affecting to visitor's circulation, and these do not speak for all space connection forms at the museum, but may systematize typology about connection form of unit spaces to utilize by indicator pointer of space planning if continue study to various spatial sphere more than hereafter. Unit exhibition area, divide connection form of space by grid and tree and laying stress on this quantitative data by spectator follow-up survey comparison and Estimate that space connection form provides partial basis of judgement for supposition that can promote direction and circulation path about visitor's movement if summarize result of investigation and analysis (III).

Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket (천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능)

  • Lee, Seung-Jae;Kwak, Eui-Shin;Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

Speech Synthesis using Diphone Clustering and Improved Spectral Smoothing (다이폰 군집화와 개선된 스펙트럼 완만화에 의한 음성합성)

  • Jang, Hyo-Jong;Kim, Kwan-Jung;Kim, Gye-Young;Choi, Hyung-Il
    • The KIPS Transactions:PartB
    • /
    • v.10B no.6
    • /
    • pp.665-672
    • /
    • 2003
  • This paper describes a speech synthesis technique by concatenating unit phoneme. At that time, a major problem is that discontinuity is happened from connection part between unit phonemes, especially from connection part between unit phonemes recorded by different persons. To solve the problem, this paper uses clustered diphone, and proposes a spectral smoothing technique, not only using formant trajectory and distribution characteristic of spectrum but also reflecting human's acoustic characteristic. That is, the proposed technique performs unit phoneme clustering using distribution characteristic of spectrum at connection part between unit phonemes and decides a quantity and a scope for the smoothing by considering human's acoustic characteristic at the connection part of unit phonemes, and then performs the spectral smoothing using weights calculated along a time axes at the border of two diphones. The proposed technique removes the discontinuity and minimizes the distortion which can be occurred by spectrum smoothing. For the purpose of the performance evaluation, we test on five hundred diphones which are extracted from twenty sentences recorded by five persons, and show the experimental results.

Segmentation of region strings using connection-characteristic function (연결특성함수를 이용한 문서화상에서의 영역 분리와 문자열 추출)

  • 김석태;이대원;박찬용;남궁재찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.11
    • /
    • pp.2531-2542
    • /
    • 1997
  • This paper describes a method for region segmentation and string extractionin documents which are mixed with text, graphic and picture images by the use of the structural characteristic of connceted components. In segmentation of non-text regionas, with connection-characteristic functions which are made by structural characteristic of connected components, segmentation process is progressed. In the string extraction, first we organize basic-unit-region of which vertical and horizontal length are 1/4 of average length of connection components. Second, by merging the basic-unit-regions one other that have smaller values than a given connection intensity threshold. Third, by linking the word blocks with similar block anagles, initial strings are cresed. Finally the whold strings are generated by merging remaining word blocks whose angles are not decided, if their height and prosition are similar to the initial strings. This method can extract strings that are neither horizontal nor of various character sizes. Through computer exteriments with different style documents, we have shown that the feasibility of our method successes.

  • PDF

Development of Hybrid FRP-Concrete Composite Pile Connection (하이브리드 FRP-Concrete 복합말뚝의 연결부의 개발)

  • Lee, Hyoung-Kyu;Park, Joon-Seok
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.4
    • /
    • pp.52-57
    • /
    • 2014
  • Due to the advantageous mechanical properties of the fiber reinforced polymeric plastics(FRP), their application in the construction industries is ever increasing trend, as a substitute of structural steel which is highly vulnerable under hazardous environmental conditions (i.e., corrosion, humidity, etc.). In this study, hybrid FRP-concrete composite pile (HCFFT) connection is suggested. The HCFFT is consisted of pultruded FRP unit module, filament wound FRP which is in the outside of mandrel composed of circular shaped assembly of pultruded FRP unit modules, and concrete which is casted inside of the circular tube shaped hybrid FRP pile. Therefore, pultruded FRP can increase the flexural load carrying capacity, filament wound FRP and concrete filled inside can increase axial load carrying capacity. In the study, connection capacity of HCFFT(small and mid size) is investigated throughout experiments and finite element method. From the results of experiments, we suggested the connection methods about HCFFT pile connection.