• 제목/요약/키워드: Confined water

검색결과 230건 처리시간 0.033초

용매증발기반 자기조립을 이용한 단일벽 탄소나노튜브 정렬 및 트랜지스터 응용 (Evaporative Self-Assembly of Single-Walled Carbon Nanotubes for Field Effect Transistor)

  • 강석희;정도영;엄성운;황청석;홍석원
    • 한국재료학회지
    • /
    • 제23권8호
    • /
    • pp.453-461
    • /
    • 2013
  • Controlling the stick and slip motions of the contact lines in a confined geometry comprised of a spherical lens with a flat substrate is useful for manufacturing polymer ring patterns. We used a sphere on a flat geometry, by which we could control the interfaces of the solution, vapor and substrate. By this method, hundreds of concentric ring-pattern formations of a linear conjugated polymer, poly [2-methoxy-5-(2-thylhexyloxy)-1,4-phenylenevinylene] (MEH-PPV), were generated with excellent regularity over large areas after complete solvent evaporation. Subsequently, the MEH-PPV ring patterns played a role as a directed template to organize highly regular concentric rings of single-walled carbon nanotubes(SWCNTs); when a droplet of the SWCNT suspension in water was casted onto the prepared substrate, hydrophobic polymer patterns confined the water dispersed SWCNTs in between the hydrophilicized $SiO_2/Si$ substrate. As the solvent evaporated, SWCNT-rings were formed in between MEH-PPV rings with controlled density. Finally, we used a lift-off process to produce SWCNT patterns by the removal of a sacrificial polymer template with organic solvent. We also fabricated a field effect transistor using self-assembled SWCNT networks on a $SiO_2/Si$ substrate.

평면 충돌제트에서 노즐 깃이 단상 및 비등 열전달에 미치는 영향 (The Effect of Nozzle Collar on Single Phase and Boiling Heat Transfer by Planar Impinging Jet)

  • 신창환;임성환;우성제;조형희
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.878-885
    • /
    • 2005
  • The water jet impingement cooling is one of the techniques to remove the heat from high heat flux equipments. Local heat transfer of the confined water impinging jet and the effect of nozzle collar to enhance the heat transfer are investigated in the fee surface jet and submerged jet. Boiling is initiated from the farthest downstream and increase of the wall temperature is reduced with developing boiling, forming the flat temperature distributions. The reduction in the nozzle-to-surface distance fur H/W$\le$1 causes significant increases and distribution changes of heat transfer. Developed boiling reduces the differences of heat transfer for various conditions. The nozzle collar is employed at the nozzle exit. The distances from heated surface to nozzle collar, Hc are 0.25W, 0.5W and 1.0W. The liquid film thickness is reduced and the velocity of wall jet increases as decreased spacing of collar to heated surface. Heat transfer is enhanced fur region from the stagnation to x/W$\~$8 in the free surface jet and to x/W$\~$5 in the submerged jet. For nucleate boiling region of further downstream, the heat transfer by the nozzle collar is decreased in submerged jet comparing with higher velocity condition. It is because the increased velocity by collar is de-accelerated downstream.

호소수내 암모니아성 질소 및 인 동시 제거를 위한 란탄-제올라이트 복합체 개발 (Development of La(III)-zeolite Composite for the Simultaneous Removal of Ammonium Nitrogen and Phosphate in Confined Water Bodies)

  • 백주헌;김금용;류홍덕;이상일
    • 대한환경공학회지
    • /
    • 제32권8호
    • /
    • pp.761-766
    • /
    • 2010
  • 본 연구에서는 인 및 암모니아 흡착에 효과적인 La(III) 및 제올라이트를 적절히 결합하여 호소수 및 연못 등의 질소 및 인을 동시에 효과적으로 제거할 수 있는 La(III)-zeolite 복합체 개발을 목적으로 하였다. 연구 결과 La(III)-zeolite 복합체 제조 시 최적 결합 비는 0.0048 La(III) g:1 zeolite g 인 것으로 나타났다. 복합체 제조 시 건조 온도는 인 흡착에 결정적인 영향을 주는 것으로 나타났는데 상온 건조가 가장 적합한 것으로 관찰되었다. La(III)-zeolite 복합체 최적 주입량은 4.052 g/L로 나타났다. La(III)-zeolite 복합체 주입 시 최적 흡착 시간은 90 분으로 나타났다. 수용액상에서 알칼리도의 존재는 암모니아 및 인흡착에 긍정적인 영향을 주는 것으로 관찰되었다. 상온에서 건조시킨 La(III)-zeolite 복합체는 용액 내에서 La(III)의 탈리 현상이 관찰되지 않았으며, 이는 La(III)-zeolite 복합체가 인을 흡착하여 바닥에 가라앉은 후 바닥으로부터 용출되는 인을 효과적으로 차단 할 수 있음을 의미한다.

Molecular-dynamic simulation on the equilibrium and dynamical properties of fluids in a nano-channel

  • Hoang, H.;Kang, S.;Suh, Y.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.208-214
    • /
    • 2008
  • The equilibrium molecular-dynamic simulations have been performed to estimate the properties of the three kinds of fluids (the Lennard-Jones fluid, water and aqueous sodium-chloride solution) confined between two plates that are separated by 1.086 nm; included in the equilibrium properties are the density distribution and the static structure, and the diffusivity in the dynamic property. Three kinds of fluids considered in this study are. The water molecules are modeled by using the SPC/E model and the ions by the charged Lennard-Jones particle model. To treat the water molecules, we combined the quaternion coordinates with Euler angles. We also proposed a plausible algorithm to assign the initial position and direction of molecules. The influence of polarization of water molecules as well as the presence of ions in the solution on the properties will be addressed in this study. In addition, we performed the non-equilibrium molecular-dynamic simulation to compute the flow velocity for the case with the gravitational force acting on molecules.

  • PDF

Molecular-dynamic simulation on the equilibrium and dynamical properties of fluids in a nano-channel

  • Hoang, H.;Kang, S.;Suh, Y.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.208-214
    • /
    • 2008
  • The equilibrium molecular-dynamic simulations have been performed to estimate the properties of the three kinds of fluids (the Lennard-Jones fluid, water and aqueous sodium-chloride solution) confined between two plates that are separated by 1.086 nm; included in the equilibrium properties are the density distribution and the static structure, and the diffusivity in the dynamic property. Three kinds of fluids considered in this study are. The water molecules are modeled by using the SPC/E model and the ions by the charged Lennard-Jones particle model. To treat the water molecules, we combined the quaternion coordinates with Euler angles. We also proposed a plausible algorithm to assign the initial position and direction of molecules. The influence of polarization of water molecules as well as the presence of ions in the solution on the properties will be addressed in this study. In addition, we performed the non-equilibrium molecular-dynamic simulation to compute the flow velocity for the case with the gravitational force acting on molecules.

  • PDF

MOLECULAR-DYNAMIC SIMULATION ON THE STATICAL AND DYNAMICAL PROPERTIES OF FLUIDS IN A NANO-CHANNEL

  • Hoang, Hai;Kang, Sang-Mo;Suh, Yong-Kweon
    • 한국전산유체공학회지
    • /
    • 제14권1호
    • /
    • pp.24-34
    • /
    • 2009
  • The equilibrium molecular-dynamic simulations have been performed to estimate the properties of the three kinds of fluids confined between two plates that are separated by 1.086 nm; included in the statical properties are the density distribution and the static structure, and the autocorrelation velocity function in the dynamic property. Three kinds of fluids considered in this study are the Lennard-Jones fluid, water and aqueous sodium-chloride solution. The water molecules are modeled by using the SPC/E model and the ions by the charged Lennard-Jones particle model. To treat the water molecules, we combined the quaternion coordinates with Euler angles. We also proposed a plausible algorithm to assign the initial position and direction of molecules. The influence of polarization of water molecules as well as the presence of ions in the solution on the properties will be addressed in this study. In addition, we performed the non-equilibrium molecular-dynamic simulation to compute the flow velocity for the case with the gravitational force acting on molecules.

3차원 콜로이드 광결정의 고속 제작 및 응용 (Quick Fabrication of Three Dimensional Colloidal Crystals and Their Applications)

  • 이수진;임상혁
    • Korean Chemical Engineering Research
    • /
    • 제51권5호
    • /
    • pp.640-643
    • /
    • 2013
  • 폴리스티렌 콜로이드 에멀젼 용액에서 물이 증발하게 되면 순간적으로 폴리스티렌 콜로이드 입자들이 물 표면으로 튀어나오게 되며 이러한 입자들 간의 모세관력에 의해 자기조립이 일어나게 되는데, 폴리스티렌 입자의 경우 유효밀도가 물 보다 작아 물 표면 위에 3차원 광결정을 형성하게 된다. 본 논문에서는 이러한 현상을 젖음성이 있는 제한된 공간을 가지는 구조를 가지는 유리기판 위에서 일어나도록 함으로써, 3차원의 폴리스티렌 콜로이드 결정이 고속으로 생성되고 기판위로 옮겨질 수 있도록 고안하였다. 고속으로 제작된 폴리스티렌 콜로이드 광결정은 폴리스티렌 입자의 크기 및 광결정 필름의 입사각을 조절하여 가시광 전체 영역의 빛을 선택적으로 반사하는 광필터로 적용해 보았다.

다중 환경추적자를 이용한 제주도 지하수 유동 및 수질 특성 분석

  • 고동찬;김용재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.138-141
    • /
    • 2004
  • The environmental tracers tritium/helium-3 (3H/3He) and chlorofluorocarbons (CFCs) were investigated in ground water from Jeju Island, Korea, a basaltic volcanic island. The apparent 3H/3He and CFC-12 ages were in relatively good agreement in samples with low concentrations of terrigenic He. Ground water mixing was evaluated by comparing 3H and CFC-12 concentrations with mixing models, which distinguished old water with negligible 3H and CFC-12, young water with piston flow, and binary mixtures of the two end members. The ground water CFC-12 age is much older in water from wells completed in confined zones of the hydro-volcanic Seoguipo formation in coastal areas than in water from the basaltic aquifer. Comparison of major element concentrations in ground water with the CFC-12 age shows that nitrate contamination processes contribute more solutes in young water than are derived from water-rock interactions in non-contaminated old water. Chemical evolution of ground water resulting from silicate weathering in basaltic rocks reaches the zeolite-smectite phase boundary. The calcite saturation state of ground water increased with the CFC-12 apparent (piston flow) age. In agricultural areas, the temporal trend of nitrate concentration in ground water was consistent with the known history of chemical fertilizer use on Jeju Island, but the response of nitrate concentration in ground water to nitrogen inputs follows an approximate 10-year delay. Based on mass balance calculations, it was estimated that about 40% of the nitrogen applied by fertilizers reached the water table and contaminated ground water resources when the fertilizer use was at the highest level.

  • PDF

Thermal Effluent through Extruded Side Channel

  • Yoon, Tae-Hoon;Yook, Woon-Soo;Yi, Young-Kon
    • Korean Journal of Hydrosciences
    • /
    • 제6권
    • /
    • pp.67-79
    • /
    • 1995
  • The reattachment of buoyant efflluent to a shore in a crossflow is investigated experimentally. The effluent is prodeced by discharging heated water through a projected side channel into a confined crossflow of the same depth. In the projecting effluent, the size of recirculating region, which is formed by deflected thermal plume on the lee of the effluent, tends to increase, but the maximum temperature decreases in the direction of the crossflow and it has more uniform transverse spreading compared to non-projected type. The heat flux across the crossflow is found to be independent of the projceted length of the side channel under relatively high buoyancy flux on the contrary to low buoyancy flux. The reattachment of th effluent can be specified by both velocity ratio and densimetric Froude number, whereas only the velocity ratio is governing factor to the reattachment of the effluent in the case of non-projecting type.

  • PDF

The Monitoring Comparative Results of Floodplain Ecosystems in Regulated and Natural Part of the Danube River (Geisling-Passau)

  • Kouzmina, Janna;Treshkin, Sergey;Henrichfreise, Alfons
    • The Korean Journal of Ecology
    • /
    • 제27권4호
    • /
    • pp.211-216
    • /
    • 2004
  • The complex ecological researches were made in the broad-leaved forest zone of Central Europe in nature reserves and national parks located on the banks of the river (hydrology, vegetation, soils, unconfined ground waters). The natural conditions of terrestrial ecosystems and natural sites were compared along the course of the rivers. The significant negative influence of low-dammed (low-confined hydrotechnic) construction and small reservoirs on vegetation and soils of floodplain was revealed. On the basis of analysis of mean annual water level and flow trends on the multi-years series (60-100 years) of the hydrometric stations on the rivers under consideration the significant influence of natural long-term variability of watering on vegetation dynamics in the floodplains was revealed.