• Title/Summary/Keyword: Cone-Beam Computed

Search Result 827, Processing Time 0.023 seconds

Positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (Cone beam형 전산화단층영상을 이용한 상악동저와 상악제1대구치 치근단괴의 위치관계)

  • Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.38 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • Purpose: To assess the positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (CBCT). Materials and Methods: CBCTs from 127 subjects were analysed. A total of 134 maxillary first molars were classified according to their vertical and horizontal positional relationship to the maxillary sinus floor and measured according to the distance between the maxillary sinus floor and the maxillary first molar. Results: Type III (The root projected laterally on the sinus cavity but its apex is outside the sinus boundaries) was dominated between 10 and 19 years and type I (The root apex was not in contact with the cortical borders of the sinus) was dominated (P<0.05) between 20 and 72 years on the vertical relationship between the maxillary sinus floor and the apex of the maxillary first molar. The maxillary sinus floor was located more at the apex (78.2%) than at the furcation (21.3%) for the palatal root. The distance from the root apex to the maxillary sinus floor confined to type I was increased according to the ages (P<0.05). Type M (The maxillary sinus floor was located between the buccal and the palatal root) was most common (72.4%) on the horizontal relationship between the maxillary sinus floor and the apex of the maxillary first molar. Conclusion: CBCT can provide highly qualified images for the maxillary sinus floor and the root apex of the maxillary first molar.

  • PDF

Comparison between cone beam computed tomography and magnetic resonance imaging of the temporomandibular joint (측두하악관절에 대한 cone beam형 전산화단층영상과 자기공명영상의 비교)

  • Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.153-161
    • /
    • 2008
  • Purpose : To compare and evaluate the diagnostic ability of cone beam computed tomography (CBCT) and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ). Materials and Methods : CBCT and MRI of 46 TMJs of 23 patients with TMJ disorders were evaluated. They were divided into 3 groups according to the position of the articular disc of the TMJ at closed mouth position and the reduction of the disc during open mouth position on MRI: no disc displacement group (NDD), disc displacement with reduction group (DDR), and disc displacement without reduction group (DDWR). With PACS viewing soft-wares, position of mandibular condyle in the articular fossa, osseous change of mandibular condyle, shape of articular fossa, and mediolateral and anteroposterior dimensions of mandibular condyle were evaluated on CBCT and MRI. Each value was tested statistically. Results : The position of mandibular condyle in the articular fossa were concentric in the NDD, DDR, and DDWR of CBCT and NDD of MRI. However, condyle was positioned posteriorly in DDR and DDWR of MRI. Flattening, sclerosis and osteophyte of the mandibular condyle were much more apparent on DDR of CBCT than MRI. And the erosion of the condyle was much more apparent on DDWR of MRI than CBCT. Box and Sigmoid types of articular fossa were found most frequently in DDR of MRI. Flattened type was found most frequently in DDR of CBCT and deformed type was found most frequently in DDWR of CBCT. No significant difference in mediolateral and anteroposterior dimensions were shown on CBCT and MRI. Conclusion : Since MRI and CBCT has unique diagnostic imaging ability, both modalities should be used together to supplement each other to evaluate TMJ.

  • PDF

Maxillary sinus pneumatization after maxillary molar extraction assessed with cone beam computed tomography (Cone Beam형 전산화단층영상을 이용한 상악대구치 발치 후 상악동 함기화 평가)

  • Jung, Yun-Hoa;Nah, Kyung-Soo;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.109-113
    • /
    • 2009
  • Purpose : The purpose of this study was to examine the inferior expansion of the maxillary sinus floor following maxillary molar extraction. Materials and Methods : Cone beam computed tomographic images of 59 subjects were used to evaluate the height difference of the maxillary sinus floor between extraction sites and contralateral dentate sites. The height of the maxillary sinus floor was defined as the vertical distance to the Frankfort plane from the level of the anterior nasal spine to the most inferior point of the sinus floor. We examined the difference in sinus pneumatization according to the number of missing teeth and the vertical relationship of the molar roots to the sinus floor. Results : The inferior expansion of the maxillary sinus floor was $1.20{\pm}1.86\;mm$ on the maxillary first molar and $1.90{\pm}2.42\;mm$ on the maxillary second molar. Increased expansion was observed in cases where two proximate molars were extracted. There was no significant difference in sinus pneumatization following extraction according to the vertical relationship of the molar roots to the sinus floor. Conclusion : The results of this study confirm that sinus pneumatization occurs following maxillary molar extraction. In situations where pneumatization can affect treatment after molar extraction, three-dimensional radiography should be considered.

  • PDF

Observation of the anterior loop and mental foramen of the mandibular canal using cone beam computed tomograph (Cone beam형 전산화단층영상을 이용한 하악관의 전방고리 및 이공에 관한 연구)

  • Koh, Kwang-Joon;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • v.39 no.2
    • /
    • pp.81-87
    • /
    • 2009
  • Purpose: To evaluate the anteroposterior length and buccal angle of the anterior loop, and the size and location of the mental foramen using cone beam computed tomography (CBCT). Materials and Methods: 100 CBCT images from 87 adults (43 males and 44 females) ranging in age from 20 to 73 years (average 50 years) with edentulous ridge of the mandibular premolar region were obtained. Axial, sagittal, coronal images were reconstructed from Dental and Block Images of CBCT. The anteroposterior length, shape and buccal angle of the anterior loop, and the size and location of the mental foramen were calculated from reconstructed images of axial, sagittal and coronal CBCT. Results: The anteroposterior length and buccal angle of the mental canal was 4.0${\pm}$1.2mm, 37.8${\pm}$11.60$^{\circ}$respectively. The loop type with straight course was the most common shape of the mental canal. The location of the mental foramen below the apex of the lower second premolar (78%) was the most common. The maximum size of the mental foramen was 4.6${\pm}$1.0 mm in width and 3.0${\pm}$0.6 mm in height. The inner size of the mental canal was 2.6${\pm}$0.6 mm in width and 2.1 mm${\pm}$0.4 mm in height. Conclusion: CBCT is useful to evaluate the anterior loop and mental foramen of the mandibular canal. Safe guideline of 4 mm from the most anterior point of the mental foramen is recommended for implant and surgical treatment. (Korean J Oral Maxillofac Radiol 2009; 39: 81-7)

  • PDF

Nutrient canals on mandibular anterior region in cone beam computed tomography (Cone beam형 전산화 단층영상을 이용한 하악전치부 영양관의 연구)

  • Kang Jung-Ho;Kim Gyu-Tae;Choi Yong-Suk;Hwang Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.137-143
    • /
    • 2006
  • Purpose : To evaluate location, distribution, diameter, and length of the nutrient canals on mandibular anterior region using a cone beam computed tomography (CBCT). Materials and Methods : Mandibular CBCT was performed on 33 adults (18 males and 15 females) with no history of systemic disease, and any other dental surgery history Location, distribution, diameter, and length of the nutrient canals on mandibular anterior region were radiographically evaluated. A statistical comparison was done by SPSS. Results : In the location and distribution of nutrient canals, they were found in 6.8% at labial portion above root apex, in 93.28% at lingual portion above root apex in 46.2% at labial portion below root apex, and in 53.6% at lingual portion below root apex. Nutrient canals at lingual portion above root apex were most frequently observed between central and lateral incisors, and those at labial and lingual portion below root apex were most frequently observed between central incisors. The mean diameters of nutrient canals were 0.54 mm at labial portion above root apex, 0.61 mm at lingual portion above root apex, 0.66 mm at labial portion below root apex, and 0.76 mm at lingual portion below root apex. The mean lengths of nutrient canals were 2.63 mm at labial portion above root apex, 3.74 mm at lingual portion above root apex, 4.51 mm at labial portion below root apex, and 6.77 mm at lingual portion below root apex. Conclusion : CBCT is useful device to evaluate the anatomical structure of nutrient canals on mandibular anterior region.

  • PDF

Radiation absorbed doses of cone beam computed tomography (Cone beam형 전산화단층촬영에 의한 흡수선량)

  • Lee, Eui-Tae;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • Purpose: To measure the absorbed doses of cone beam computed tomography (CBCT), which is recently being more frequently used, and to compare them with those of panoramic radiography. Materials and Methods: To measure the absorbed doses of CBCT ($PSR-9000N^{TM}$, Asahi Roentgen Ind. Co., Japan), we placed TLD chips on the skin regions above the parotid and thyroid glands, and on the dorsum of tongue in a dental head phantom. We used two image acquisition modes of the Dental and Panoramic modes of CBCT, which differed in the field of view. Also, panoramic radiographs (Auto IIIN, Asahi Roentgen Ind. Co., Japan) were taken to compare with the absorbed doses of CBCT. Result: In the Dental mode of CBCT, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 3.53, 3.13, and 0.36 mGy, respectively. In the Panoramic mode of CBCT, they were 9.57, 9.15, and 0.85 mGy, respectively. The panoramic mode showed higher absorbed doses than those of the Dental mode. In the panoramic radiography, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 1.21, 1.19, and 0.16 mGy, respectively. And they were about 1/3 of the Dental mode and 1/9 of the Panoramic mode of CBCT. Conclusion: Absorbed doses of CBCT are higher than those of panoramic radiography, and dependent upon the field of view.

  • PDF

Evaluation of danger zone in mesial root of mandibular first molar by cone beam computed tomography (CBCT) (Cone beam형 전산화단층촬영장치를 이용한 하악 제1대구치 근심 치근의 danger zone에 관한 연구)

  • Chang, Yoo-Rhee;Choi, Yong-Suk;Choi, Gi-Woon;Park, Sang-Hyuk
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.103-110
    • /
    • 2007
  • Purpose: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT (cone-beam computed tomography) to avoid the risk of root perforation. Materials and Methods: 20 mandibular first molars without caries and restorations were collected, CT images were obtained by CBCT ($PSR9000N^{TM}$, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea), Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured, Results: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm, Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm, The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D, MB-D is thinner than ML-D although the differences is not significant. Conclusion: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.

  • PDF

Cone Beam Computed Tomography Analysis of Mandibular Anatomical Variation in a Patient with Facial Asymmetry (안면 비대칭 환자에서 Cone Beam Computed Tomography를 이용한 하악골 해부학적 변이의 분석)

  • Park, Seong-Won;Oh, Sung-Hwan;Lee, Jae-In
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.34-40
    • /
    • 2012
  • Purpose: The study was performed to compare patients with anatomical variations in facial asymmetry with patients in the normal range using cone-beam computed tomography (CBCT) and to take the preoperative condition into consideration in the case of a sagittal split ramus osteotomy (SSRO). Methods: The study was conducted on 46 adult patients composed of 2 subdivided groups, an asymmetry group (n=26) and a symmetry group (n=20). The asymmetry group was divided between patients with hemimandibular hyperplasia (HH, n=8) and hemimandibular elongation (HE, n=18). Using cross-sectional computed tomography images, the thickness of cancelleous bone in the buccal area of the mandible, thickness of buccal cortex in the buccal aspect of the mandible, thickness of cancellous bone in the inferior aspect of the mandible, thickness of buccal cortex in the inferior aspect of the mandible, and cross-sectional surface area of the mandible were measured. Results: In the asymmetry group, the cross-sectional area of the mandible including the inferior alveolar nerve positioned on the affected side was significantly different from the symmetry group. Thickness of cancelleous bone in the buccal aspect of the mandible, thickness of cancelleous bone in the inferior aspect of the mandible, and cross-sectional surface area of the mandible in the affected site of hemimandibular hyperplasia was significantly smaller than in the symmetry group. Conclusion: The inferior alveolar nerve runs lower and in a more buccal direction and shows a smaller cross-sectional surface of the mandible in the hemimandibular hyperplasia patients with asymmetry.

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.