• 제목/요약/키워드: Cone pressuremeter

검색결과 7건 처리시간 0.015초

Cone Pressuremeter, PMT, Vane 시험을 이용한 지반조사 사례연구 (The practical aprication of Cone Pressuremeter, PMT, Vane tests to site investigation)

  • 이장덕;구자갑;김종수;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.323-330
    • /
    • 1999
  • The concepts of mounting a pressuremeter module behind a cone penetrometer was applied in the early 1980s. The pressuremeter module is of 40mm diameter with length / diameter ratio of 10 inflated by nitrogen gas. This cone pressuremeter(CPM) is used to obtain the ground characteristics consisted of mainly silty, clay and sand. Field tests such as SPT, PMT, Vane tests are also carried out to understand the ground condition. Undisturbed samples are obtained to carried out Lah tests. The results of these field and lab tests are presented, discussed in detail, and compared with each others.

  • PDF

Cone Pressuremeter를 이용한 점성토의 전단 강도 산정 (Determination of Undrained Shear Strength In Clay from Cone Pressuremeter Test)

  • 이장덕
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.49-58
    • /
    • 2004
  • 콘프레셔미터는 피에조콘 시험과 프레셔미터 시험을 동시에 수행할 수 있는 현장시험기로서 본 연구에서는 국내 점토지반에서 수행한 시험결과를 해석적으로 분석하였다. 콘프레셔미터 결과에 대한 이론적인 해는 흙이 비선형 거동을 하는 경우와 전단변형 중 체적변화가 발생하지 않는 경우에 대하여 해석적인 해가 존재한다. 이러한 해석적인 해로부터 콘프레셔미터의 결과중 하중 재하구간과 제하구간에 대해 Curve Fitting 방법을 사용한 콘프레셔미터 결과의 해석 방법을 제안하였다. 20개소의 현장에서 수행한 콘프레셔미터 결과 중 지반교란의 영향을 적게 받는 제하구간에 대하여 Curve Fitting 방법을 적용하여 점성토의 비배수 전단특성을 구하였다. 이렇게 구한 지반의 비배수 전단강도와 현장 Vane, 일축압축, 삼축압축 시험결과로부터 구한 지반의 비배수 전단강도를 서로 비교하여 콘프레셔미터 시험 결과로부터 Curve Fitting 방법을 통한 점성토 지반의 전단강도 특성파악의 적정성에 대해 평가하였다.

Cone Pressuremeter Test를 이용한 미소변형에서 전단변형계수 측정 (Measurement of Shear Modulus at Small Strains using Cone Pressuremeter Test)

  • 이장덕
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.135-145
    • /
    • 2005
  • 공용하중 상태에서 지반이 경험하는 변형률 크기는 0.1%~1% 미만임이 밝혀지고 있다. 변형특성보다 엄밀히 평가하기 위하여는 미소변형률 영역에서의 신뢰성 있는 변형측정을 위해 현장시험장비가 필요한 실정이다. 콘과 공내재하시험기를 혼합한 Cone-pressuremeter test(CPM)을 서해안 연약 해성점토층에 수행하였다. 반교란효과를 최소화시키기 위해 제하-재하 Loop를 이용하여 탄성계수를 측정하였으며 공동확장이론의 공내 재하시험 이론식을 이용하여 지반교란이 최소화된 제하단계에 대한 Curve Fitting 방법으로부터 지반의 비배수 강도와 탄성계수를 측정하였다. 측정된 탄성계수, 비배수 강도의 비를 평가해본 결과 $E_u/S_u$가 589로 다른 삼축시험 등 실내시험보다 크게 평가되어 미소변형하의 탄성계수를 신뢰성 있게 산정할 수 있는 것으로 평가되어 수치해석을 통한 지반물성치 산정에 매우 효과적으로 사용할 수 있을 것으로 기대된다.

율촌 복합화력발전소 공내 재하 시험 (Pressuremeter Test in YULCHON Combined Cycle Power Plant)

  • 이용길;박경호
    • 한국지반환경공학회 논문집
    • /
    • 제2권1호
    • /
    • pp.5-13
    • /
    • 2001
  • 본 논문의 목적은 율촌 복합화력발전소 부지에 대한 지지력 산정 및 지반 특성 파악을 위한 공내재하시험의 결과를 분석하는 것이다. 율촌 복합화력발전소 부지는 인근의 야산 토취장에서 매립토를 채취 운반하여 강제치환공법으로 성토하였으며, 지질은 상부로부터 산토, 준설매립해성점토, 실트집모래, 원지반해성점토층, 풍화대, 풍화암, 연암의 순으로 존재한다. 공내재하시험은 해성점성토층을 제외한 토층에 대하여 토층의 특성에 따라 각각 다른 크기의 Probe와 Membrane을 사용하여 수행하였으며, 콘시험과의 상관성, 내부 마찰각과의 관계 및 토질 특성을 파악하였다.

  • PDF

공내재하시험을 이용한 지반정수 평가 (Evaluation of Soil Properties using Pressuremeter Test)

  • 한상연;장서만;전성곤;이종규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

현장시험에 의한 Smear Zone의 평가 (A Study on the Evaluation of Smear Zone by In-situ Tests)

  • 이장덕;구자갑
    • 한국지반공학회논문집
    • /
    • 제19권6호
    • /
    • pp.207-216
    • /
    • 2003
  • 본 논문에서는 국내 서해안 연약 지반 현장에서 PBD 타설로 인한 교란 영역을 확인하기 위하여 현장지반에 10개의 간극수압계를 PBD 타설 위치로부터 10cm, 20cm, 30cm, 40cm 그리고 50cm 그리고 50cm 떨어져 설치하고 멘드렐을 이용한 PBD 강제 관입시 발생하는 과잉간극수압의 소산과정을 5m, 7m 깊이에서 측정하였다. PBD 타설로 인해 지반교란이 발생하면 연약점토 지반의 투수계수가 감소하게 되어 과잉간극수압의 소산시간에 영향을 미치게 되므로 PBD 타설거리로부터 PBD 타설 전후의 과잉간극수압 소산과정을 측정하여 Smear Zone의 범위를 정하였다. 또한 이러한 과잉간극수압 소산과정을 해석하여 PBD타설 전후의 지반 배수특성저하를 규명하였다. 과잉간극수압 소산을 해석하기 위하여 시험 지반의 강성지수가 필요한데 이러한 강성지수 측정을 위하여 Cone-Pressuremeter(CPM)시험을 병행하였다. 시험결과 멘드렐의 환산직경의 3.0-3.6배에 Smear Zone이 형성되는 것으로 조사되었으며 Teh & Houlsby의 식과 CPM을 이용한 수평압밀계수를 평가한 결과 PBD타설전후로 지반의 배수능력이 3-8배 저하된 것으로 계산되었다.

다양한 시험 방법을 이용한 서해안 송도 지역에 분포하는 실트질 모래의 최대 전단탄성계수 평가 (Evaluation of Maximum Shear Modulus of Silty Sand in Songdo Area in the West Coast of Korea Using Various Testing Methods)

  • 정명훈;이강원;김명모;권형민;정충기
    • 한국지반공학회논문집
    • /
    • 제21권9호
    • /
    • pp.65-75
    • /
    • 2005
  • 흙의 최대 전단탄성계수는 동적/정적 지반구조물 설계에서 중요하게 다루어야 하는 기본 토질상수이다. 본 연구에서는 서해안 송도 지역의 실트질 모래에 대해 표준관입시험, 콘관입시험, 자가굴착식 공내재하시험, 다운홀 시험, 탄성파 탐사 콘관입시험, 공진주 시험 등을 수행하여 최대 전단탄성계수를 구하고 그 결과를 통계적으로 분석하였다. 다운홀 시험을 기준으로 표준관입시험 및 콘관입시험에 대한 경험식으로 구한 최대 전단탄성계수를 비교하고 새로운 경험식물 제안하였다. 제안식으로 구한 전단탄성계수는 다운홀 시험 결과와 비교적 잘 일치하였으며, 제안식을 이용하여 적절히 지반의 최대 전단탄성계수를 평가할 수 있음을 확인하였다.