• Title/Summary/Keyword: Cone nail system

Search Result 2, Processing Time 0.017 seconds

Evaluation of Long-Term Behaviors of the Cone Nailing System using Geotechnical Centrifuge Guidelines (원심모형실험을 이용한 방추형 콘 네일링 시스템의 장기거동 특성 평가)

  • Park, Si-Sam;Bae, Woo-Seok;Jung, Woo-Chul;Kim, Hong-Taek;Kim, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.744-751
    • /
    • 2006
  • In case of the Soil Nail System applied to a slope, effects of vibrations from blasting, earthquake and creep of long term behaviors cause reductions of adhesion between grout and soil-nail. There are some reports of nail's pull-out failure by those reasons. In this paper it is suggested that the Cone Nailing System is enable to diminish effects of vibrations and creep. In this study on Cone Nailing System, the cones are installed to each nail by 2m. By such installing cones, the adhesion between nail and grout will increase and the long term creep behavior will decrease. In this study, the centrifuge test is performed to understand the behaviors of the Cone Nail System. For the centrifuge test, the soil tank is 52cm in width, 17cm in length and 35cm in height. In comparison with general soil nail, the centrifuge test of general soil nail(without cone) is performed equally. Additionally, the interface between cone nail and soil through the pull-out test is applied to FLAC 2D version 3.3. and the evaluation of application for the Cone Nail System in slope is performed.

  • PDF

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.