• Title/Summary/Keyword: Cone Beam

Search Result 978, Processing Time 0.031 seconds

Recurrent osteochondroma of the mandibular condyle: A case report

  • Kwon, Young-Eun;Choi, Karp-Shik;An, Chang-Hyeon;Choi, So-Young;Lee, Jae-Seo;An, Seo-Young
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • A 21-year-old woman presented with facial asymmetry. Crepitus and clicking of the temporomandibular joint were noted. The midline deviated 5.5 mm to the left, and secondary malocclusion was observed. Panoramic and cone-beam computed tomographic images showed an irregular and exophytic bony mass on the anteromedial surface of the right mandibular condyle. A 3-phase bone scan revealed increased tracer uptake on the affected side. The lesion was treated with excision and reshaping under the diagnosis of osteochondroma confirmed by a histopathological examination. The lesion recurred after 3 years, and the patient underwent condylectomy. Mandibular condylar osteochondroma is often resected because it causes functional and aesthetic problems, but it rarely recurs. To the best of our knowledge, only 2 cases of recurrent osteochondromas of the mandibular condyle have been reported previously. Surgical treatment of the osteochondroma should be performed considering the possibility of recurrence, and long-term follow-up is recommended.

The Use of Lens Shielding Device(L.S.D.) for a Conjunctival Lymphoma

  • Cho Hyun Sang;Ju Sang Gyu;Song Ki Won;Park Young Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.40-45
    • /
    • 1997
  • When therapeutic irradiation is indicated for the orbital tumors, the greatest concern is the risk of radiation-induced cataract. Conjunctival lymphoma is one of the good examples. We would like to report the procedure of the lens shielding device(L.S.D) and the result of irradiated dose to the lens. L.S.D. consistes of two parts : load alloy to attenuate electron beam, and dental acryl which completely covers the lead alloy to avoid discomfort of cornea from contacting directly with cerrobend and side scattering by cerrobend. And for easy location and removal, side bars were made on each side. Radiation doses were meaured with TLD(TLD 3500 Hawshaw). Markus chamber in a polystyrene phantom. The phantom was irradiated with 9MeV electron beams from Clinac 2100C with $6{\times}6cm$ electron cone. The relative dose at 6mm depth where the lens is located was $4.2\%$ with TLD and $5.1\%$ with Markus chamber clinically when 2600 cGy are irradiated to the eyeball, the mapinary dose to the lens will be 109 cGy or 132 cGy, which will significently reduce the cataract.

  • PDF

IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices

  • Barngkgei, Imad;Halboub, Esam;Almashraqi, Abeer Abdulkareem;Khattab, Razan;Al Haffar, Iyad
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.185-202
    • /
    • 2016
  • Purpose: The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. Materials and Methods: A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. Results: The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). Conclusion: IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices.

Repeated injections of botulinum toxin into the masseter muscle induce bony changes in human adults: A longitudinal study

  • Lee, Hwa-Jin;Kim, Sung-Jin;Lee, Kee-Joon;Yu, Hyung-Seog;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.222-228
    • /
    • 2017
  • Objective: To evaluate soft- and hard-tissue changes in the mandibular angle area after the administration of botulinum toxin type A (BoNT-A) injection to patients with masseteric hypertrophy by using three-dimensional cone-beam computed tomography (3D-CBCT). Methods: Twenty volunteers were randomly divided into two groups of 10 patients. Patients in group I received a single BoNT-A injection in both masseter muscles, while those in group II received two BoNT-A injections in each masseter muscle, with the second injection being administered 4 months after the first one. In both groups, 3D-CBCT was performed before the first injection and 6 months after the first injection. Results: Masseter muscle thicknesses and cross-sectional areas were significantly reduced in both groups, but the reductions were significantly more substantial in group II than in group I. The intergonial width of the mandibular angle area did not change significantly in either group. However, the bone volume of the mandibular gonial angle area was more significantly reduced in group II than in group I. Conclusions: The repeated administration of BoNT-A injections may induce bone volume changes in the mandibular angle area.

Basic Performance Evaluation of the First Model of 4-Dimensional CT-Scanner

  • Mori, Shinichiro;Endo, Masahiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuzi;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.376-378
    • /
    • 2002
  • This work was carried out to evaluate the basic performances for 4D CT, which employed continuously rotating conebeam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D CT has not yet been established, and we think this result was helpful to establish it. 4D CT can give dynamic volume imaging data continuously and with high-speed. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in longitudinal direction.

  • PDF

Simulation Study of Optimizing Multicusp Magnetic Line Configurations for a Negative Hydrogen Ion Source

  • Kim, Jae-Hong;Hong, Seong-Gwang;Kim, Jong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.1-250.1
    • /
    • 2014
  • A multicusp ion source has been used widely in negative hydrogen cyclotrons mainly for radioisotope productions. The ion source is designed to have cusp geometries of magnetic field inside plasma chamber, where ions are confining and their mean lifetimes increase. The magnetic confinement produced a number of permanent magnetic poles helps to increase beam currents and reduce the emittance. Therefore optimizing the number of magnets confining more ions and increasing their mean lifetime in plasma has to be investigated in order to improve the performance of the ion source. In this work a numerical simulation of the magnetic flux density from a number of permanent magnets is carried to optimize the cusp geometries producing the highest plasma density, which is clearly indicated along the full-line cusp geometry. The effect of magnetic fields and a number of poles on the plasma structure are investigated by a computing tool. The electron confinement effect becomes stronger and the density increases with increasing the number of poles. On the contrary, the escape of electrons from the loss cone becomes more frequent as the pole number increases [1]. To understand above observation the electron and ion's trajectories along with different cusp geometries are simulated. The simulation has been shown that the optimized numbers of magnets can improve the ion density and uniformity.

  • PDF

Influence of surface morphology and thickness of molecular thin films on the performance of SubPc-$C_{60}$ photovoltaic devices

  • Kim, Jin-Hyun;Gong, Hye-Jin;Yim, Sang-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.336-336
    • /
    • 2011
  • Over the past decades, organic semiconductors have been investigated intensely for their potential in a wide range of optoelectronic device applications since the organic materials have advantages for very light, flexible and low cost device fabrications. In this study, we fabricated small-molecule organic solar cells (OSCs) based on chloro[subphthalocyaninato]boron(III) (SubPc) as an electron donor and $C_{60}$ as an electron acceptor material. Recently SubPc, a cone-shaped molecule with $14{\pi}$-electrons in its aromatic system, has attracted growing attention in small-molecule OSC applications as an electron-donating material for its greater open-circuit voltage (VOC), extinction coefficient and dielectric constant compared to conventional planar metal phthalocyanines. In spite of the power conversion efficiency (PCE) enhancement of small-molecule OSC using SubPc and $C_{60}$, however, the study on the interface between donor-acceptor heterojunction of this system is limited. In this work, SubPc thin films at various thicknesses were deposited by organic molecular beam deposition (OMBD) and the evolution of surface morphology was observed using atomic force microscopy (AFM) and field emission scanning electron microscopy (FE-SEM). We also investigated the influence of film thickness and surface morphology on the PCE of small-molecule OSC devices.

  • PDF

Surface Characteristics of Metallic 3D Printed Dental Framework (금속 3D printing으로 제작한 치과보철물의 표면특성)

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.21-21
    • /
    • 2018
  • 다양한 소재(금속, 세라믹, 고분자 소재 등)들이 3차원 형상기반 적층제조법에 적용되고 있는데, 금속 소재를 이용하여 3D 프린팅 법으로 치과용 수복물을 제조하는 연구가 많이 보고되고 있다. 하지만, 티타늄 또는 티타늄 합금 분말을 이용하여 3D 프린팅 법으로 제작한 치과용 보철물에 관한연구 보고는 많지 않다. Kanazawa 등 (2014)은 Ti-6Al-4V 합금분말을 이용하여 SLM법으로 총의치 용 framework를 제작하여 주조법으로 제작한 것과 비교 평가하였고, Mangano 등(2013)은 Ti-6Al-4V 합금분말로 지름이 작은 일체형 (1-piece narrow-diameter) 임플란트를 SLS법으로 제작하여 16명의 환자에게 식립한 다음, 2년간 관찰하였고, Mangano 등 (2014)은 cone-beam computed tomography (CBCT) data를 3D이미지로 변환시켜 DLMS법으로 치근 형상의 임플란트를 제작하여 15명의 환자에게 식립한 다음, 1년간 관찰하였다. 또한 서울대학교 및 연세대학교 치과생체재료과학교실 (2016)에서는 3D 프린팅 법으로 제작한 티타늄 시편과 기계 가공한 티타늄 시편의 물성을 비교하였다. 그러나 티타늄 합금 분말을 이용하여 3D 프린팅 법으로 제작한 치과용 보철물을 실제 임상에 적용하는 단계에서 기존 기계가공 방식으로 제작한 티타늄 보철물과 3D 프린팅 법으로 제작한 티타늄 보철물의 물성과 표면특성을 다양하게 비교 평가하는 것이 필요하여 본 연구에서는 3D 프린팅 법으로 제작한 티타늄 시편과 기계 가공한 티타늄 시편의 물성특성과 표면특성을 비교하여 조사하였다.

  • PDF

Hard tissue augmentation to minimize a risk of buccal gingival recession in lower anterior teeth associated with orthodontic treatment: case report (교정 치료와 관련된 하악 전치부 협측 치은 퇴축의 위험성을 최소화하기 위한 골이식 : 증례보고)

  • Yoo, Ji-Soo;Baek, Seung-Jin;Jung, Jae-Suk;Ji, Suk
    • The Journal of the Korean dental association
    • /
    • v.56 no.4
    • /
    • pp.208-216
    • /
    • 2018
  • Patients with malocclusion may present with preexisting mucogingival problems susceptible to attachment loss during or after orthodontic treatment. Lower anterior teeth especially show a high prevalence of gingival recession following orthodontic treatment. This case report demonstrates hard tissue augmentation of labially thin or deficient alveolar bone (dehiscences and fenestrations) to prevent attachment loss during or after orthodontic treatment. Three patients presented clinically prominent root surfaces and dehiscences and fenestrations on cone-beam computed tomography (CBCT) in lower anterior teeth. Labial hard tissue augmentation of lower anterior teeth was performed with deproteinized bovine bone mineral and collagen membrane. Six months later, hard tissue augmentation reduced root prominence and created a greater volume of hard tissue on lower anterior area in clinical and radiographic findings. Hard tissue augmentation using xenograft could prevent attachment loss associated with orthodontic treatment and maintain stability of healthy periodontium.

  • PDF

Orthodontic treatment of a transposed maxillary canine and first premolar in a young patient with Class III malocclusion

  • Gracco, Antonio;Siviero, Laura;Perri, Alessandro;Favero, Lorenzo;Stellini, Edoardo
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.322-332
    • /
    • 2015
  • A 12-year-old girl was referred to our clinic for evaluation of an unaesthetic dental appearance. All permanent teeth were erupted, while the deciduous maxillary right canine was retained. Cone-beam computed tomography revealed a complete transposition of the maxillary left canine and first premolar involving both the crowns and the roots. Initial cephalometric analysis showed a skeletal Class III pattern, with a slight maxillary retrusion and a compensated proclination of the upper incisors. The patient's teeth were considered to be in the correct position; therefore, we decided to attempt treatment by correcting the transposition and using only orthodontic compensation of the skeletal Class III malocclusion. After 25 months of active orthodontic treatment, the patient had a Class I molar and canine relationship on both sides, with ideal overbite and overjet values. Her profile was improved, her lips were competent, and cephalometric evaluation showed acceptable maxillary and mandibular incisor inclinations. The final panoramic radiograph showed that good root parallelism was achieved. Two-year follow-up intraoral photography showed stable results.