• 제목/요약/키워드: Conduction-cooled

검색결과 102건 처리시간 0.031초

전도냉각형 저온용기에서 중간냉각의 최적화 (Optimization of intermediate cooling in conduction-cooled cryostat)

  • 장호명;박정수;김성래;김형진;진홍범;이봉근
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.155-158
    • /
    • 2001
  • An intermediate cooling is indispensible to reduce the refrigeration power at superconducting system that is cooled conductively by a cryocooler without liquid cryogens. The cooling load at the intermediate stage is caused by the mechanical supports, the radiation shield and the current lead. From the cooling load calculation, a thermodynamic analysis that take into account the temperature-dependent properties of the materials and the actual performance of the cryocooler is developed. For any given physical dimensions of the various components, it is shown that there exist a unique optimum for the intermediate temperature to minimize the overall refrigeration power. The results of this study can be usefully applied to the selection of the cryocooler as well as the design of the conduction-cooled cryostat.

  • PDF

A study on the breakdown probability distribution of materials for conduction-cooled HTS SMES

  • Choi, J.H.;Kim, W.J.;Kim, H.J.;Seong, K.C.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.17-20
    • /
    • 2011
  • Superconducting magnetic energy storage (SMES) has attracted a great deal of interest from the viewpoint of energy saving. The magnet of conduction-cooled high temperature superconducting (HTS) SMES is cooled down by a cryocooler. One of the most important problems to be assured the protection of magnet and cryocooler is breakdown at cryogenic temperature. In this study, we investigated insulation materials such as Kapton, Aluminum Nitride(AIN), Alumina($Al_2O_3$), glass fiber reinforced plastics(GFRP) and vacuum in cryogenic temperature. Also, we analyzed statistically the Weibull distribution of breakdown voltage.

전도냉각형 초전도시스템의 전류도입선 냉각을 위한 열커패시터의 열적해석 (Thermal analysis of a thermal capacitor for the current lead cooling in conduction-cooled superconducting systems)

  • 권기범;양형석;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • In this study, thermal analysis of a thermal capacitor, which is used to cool the current lead in conduction-cooled superconducting systems, was done. The temperature difference across a thermal capacitor was calculated by using heat conduction equation. Effect of heat load, total thickness, height and length of a thermal capacitor on the temperature difference were show. Using the results in this work, total thickness and heat height of a thermal capacitor can be determined for given heat load and given temperature difference. This work can be used practically in design for every superconduction system using a current lead.

  • PDF

Estimation of surface emissivity for conduction-cooled metal plates at cryogenic temperatures

  • Chang, Ho-Myung;Lee, Gyong-Hyon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.38-41
    • /
    • 2008
  • The relation between surface emissivity and temperature distribution is experimentally and analytically investigated for a conduction-cooled metal plate in vacuum. Experimental set-up consists of a rectangular metal plate placed vertically in a cryostat and thermally anchored to the coldhead of a GM cryocooler at the top. Temperature is measured at a number of locations over the plate with platinum resistors mounted on the plate. A parallel analysis on the balance of heat conduction through the plate and thermal radiation on its surface is performed to numerically calculate the temperature distribution having the same boundary conditions as experiment. By comparing the two results, an average emissivity of the plate is roughly estimated for different metal plates and different surface conditions. The estimated emissivity in present study is less than the listed values for highly polished stainless steel, and meets a fairly good agreement for oxidized copper surface.

극저온 냉동기로 냉각되는 이중전류도입선의 최적설계 (Optimal design of binary current leads cooled by cryogenic refrigerator)

  • 송성재;장호명
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.552-560
    • /
    • 1997
  • Analysis is performed to determine the optimal lengths or cross-sectional areas of refrigerator-cooled current leads that can be applied to the conduction-cooled superconducting systems. The binary current lead is composed of the series combination of a normal metal at the upper(warm) part and a high $T_c$ superconductor(HTS) at the lower(cold) part. The heat conduction toward the cold end of HTS part constitutes a major refrigeration load. In addition, the joint between the parts should be cooled by a refrigerator in order to reduce the load at the low end and maintain the HTS part in a superconducting state. The sum of the work inputs required for the two refrigeration loads needs to be minimized for an optimal operation. In this design, three simple models that depict the refrigeration performance as functions of cooling temperature are developed based on some of the existing refrigerators. By solving one-dimensional conduction equation that take into account the temperature-dependent properties of the materials, the refrigeration works are numerically calculated for various values of the joint temperature and the sizes of two parts. The results show that for given size of HTS, there exist the optimal values for the joint temperature and the size of the normal metal. It is also found that the refrigeration work decreases as the length of HTS increases and that the optimal size of normal metal is quite independent of the size of HTS. For a given length of HTS, there is an optimal cross-sectional area and it increases as the length increases. The dependence of the optimal sizes on the refrigerator models employed are presented for 1kA leads.

  • PDF

액체/전도냉각형 초전도 시스템에서 전류도입선의 열적 해석 (Thermal analysis of Current lead for Liquid/Conduction cooling on Superconducting system)

  • 권기범;김형진;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.178-181
    • /
    • 2003
  • Intermediate cooling for current lead is used of thermal link in conduction cooling and cooled of itself in liquid cooling because it is put in liquid. If a existing formula for cooling load and optimal diameter-length of current lead is applied, it generate some more cooling load. Therefore, variation of thermal link height and holding depth in liquid is considered. This result is used of reducing cooling load of current lead occupying most of superconducting system load and applying liquid/conduction cooling systems.

  • PDF

극저온냉동기로 전도냉각되는 초전도시스템의 열적 안정성 (Thermal stability of superconducting systems conduction-cooled by cryocooler)

  • 권기범;장호명
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.56-63
    • /
    • 2001
  • The thermal stability conditions are investigated for superconducting magnet systems cooled conductively by cryocooler without liquid cryogens. The worst scenario in the systems is that the heat generation in the resistive state exceeds the refrigeration. causing a rise in the temperature of the magnet winding and leading to the burnout. It is shown by an analytical solution that in the continuous resistive state, the temperature may increase indefinitely or a stable steady-state may be reached, depending upon the relative size of the magnet with respect to the refrigeration capacity of the cryocooler. The stability criteria include the temperature-dependent Properties of the magnet materials and the refrigeration characteristics of the cryocooler. A useful graphical scheme is Presented and discussed to demonstrate the physical importance of the results.

  • PDF

The Effect of Ambient Air Condition on Heat Transfer of Hot Steel Plate Cooled by an Impinging Water Jet

  • Lee, Pil-Jong;Park, Hae-Won;Lee, Sung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.740-750
    • /
    • 2003
  • It has been observed that the cooling capacity of an impinging water jet is affected by the seasonal conditions in large-scale steel manufacturing processes. To confirm this phenomenon, cooling experiments utilizing a hot steel plate cooled by a laminar jet were conducted for two initial ambient air temperatures (10$^{\circ}C$ and 40$^{\circ}C$) in a closed chamber, performing an inverse heat conduction method for quantitative comparison. This study reveals that the cooling capacity at an air temperature of 10$^{\circ}C$ is lower than the heat extracted at 40$^{\circ}C$. The amount of total extracted heat at 10$^{\circ}C$ is 15% less than at 40$^{\circ}C$ , These results Indicate the quantity of water vapor, absorbed until saturation, affects the mechanism of boiling heat transfer.

원통 용접부의 온도분포 해석 (An Analysis on the Temperature Distribution at the Circumferential Weld Zone)

  • 남궁재관
    • 한국공작기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.221-227
    • /
    • 2009
  • The study of the solidification process of welded metal is carried out using the finite element method, which is the basic study for optimal design. In the analysis of temperature, the welded zone is cooled as the result of heat conduction to the base metal and heat transfer to the circumference. In the early phase of the temperature in base metal zone is little changed. But after the rise in temperature the whole area is cooled gradually and uniformly with the lapse of 10 seconds, and a temperature change is hardly occurred in the radial direction but in the axial direction.