• 제목/요약/키워드: Conduction Velocity

검색결과 241건 처리시간 0.027초

수평 사각밀폐공간내의 전도열전달 기구에서 열모세관효과 (The Thermocapillary Effect on Pure Conduction Mechanism in a Closed Square Cavity)

  • 유재봉;안도원;유주식;엄용균
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1209-1219
    • /
    • 2005
  • In a closed square cavity filled with a liquid, a cooling horizontal upper wall and a heating lower wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In this mechanism, Ra=1534, Temperature and velocity fields near an air-bubble in silicon-oil under a cooled upper wall were investigated. Temperature and velocity fields is visualized using the thermo-sensitive liquid-crystal and light sheet visualization technique. The quantitative analysis fer the temperature and the flow fields were carried out by applying the image processing technique to the original data. The symmetry shape of two vortexes near an air bubble was observed. As the bubble size increased, the size of vortex and the magnitude of velocity increased. In spite of elapsed time, a pair of vortexes was the unique and steady-state flow in a square cavity and wasn't induced to the other flow in the surround region.

석탄입자가 존재하는 공기중에서의 화염전파에 관한 모사 (Simulation of flame propagation in suspension of coal particles)

  • 윤길원;백승욱
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.36-43
    • /
    • 1988
  • 본 연구에서는 공기중에 석탄 또는 곡식가루 등과 같은 고체미립자가 섞여있는 반응물에서의 화염전파에 관한 모델을 수립하여 고체미립자 농도 및 가루의 입자크기 변화에 따른 화염전파 속도와 예열거리를 예측한다. 이와 아울러 모델을 수립함에 있어 화염면으로부터의 복사열 전달에 의한 고체입자의 가열, 고체입자로부터의 대류와 화염면으로부터의 전도에 의한 가열과 같은 고체와 기체간의 상호 열전달 관계를 밝히며, 최종적으로 이상유동에서의 화염전파에서 가장 중요한 요인을 밝히는데 목적이 있다.

Laminar Burning Velocities of Atmospheric Coal Air Mixtures

  • Park, Ho Young;Park, Yoon Hwa
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.89-96
    • /
    • 2016
  • The mechanism for laminar dust flame propagation can only be elucidated from a comprehensive mathematical model which incorporates conduction and radiation, as well as the chemical kinetics of particle devolatilization and gas phase and char reaction. The mathematical model for a flat, laminar, premixed coal-air flame is applied to the atmospheric coal-air mixtures studied by Smoot and co-workers, and comparisons are made with their measurements and predictions. Here the principal parameter for comparison is the laminar burning velocity. The studies of Smoot and co-workers are first reviewed and compared with those predicted by the present model. The effects of inlet temperature and devolatilization rate constants on the burning velocities are studied with the present model, and compared with their measurements and predictions. Their measured burning velocities are approximately predicted with the present model at relatively high coal concentrations, with a somewhat increased inlet temperature. From the comparisons, their model might over-estimate particle temperature and rates of devolatilization. This would enable coal-air mixtures to be burned without any form of preheat and would tend to increase their computed values of burning velocity.

저신장율 대향류확산화염에서 진동불안정성을 갖는 에지화염의 동적거동 (Dynamic Behaviors of Oscillating Edge-Flame in Low Strain Rate Counterflow Diffusion Flames)

  • 박준성;김현표;박정;김정수;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.65-72
    • /
    • 2006
  • Experiments in methane-air low strain rate counterflow diffusion flames diluted with nitrogen have been conducted to study the behavior of flame extinction and edge flame oscillation in which flame length is less than the burner diameter and thus lateral conduction heat loss in addition to radiative heat loss could be remarkable at low global strain rates. Critical mole fraction at flame extinction is examined with velocity ratio and global strain rate. Onset conditions of edge flame oscillation and flame oscillation modes are also provided with global strain rate and added nitrogen mole fraction to fuel stream (fuel Lewis number). It is seen that flame length is closely relevant to lateral heat loss, and this affects flame extinction and edge flame oscillation considerably. Edge flame oscillations in low strain rate flames are experimentally described well and are categorized into three: a growing oscillation mode, a decaying oscillation mode, and a harmonic oscillation mode. The regime of flame oscillation is also provided at low strain rate flames. Important contribution of lateral heat loss even to edge flame oscillation is clarified.

  • PDF

저신장율 대향류화염에서 화염소화에 있어서 천이에 대한 연구 (A Study on Transition of Flame Extinction at Low Strain Rate Counterflow Flames)

  • 박대근;박정;김정수;배대석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.197-201
    • /
    • 2009
  • 대향류확산화염에서 수축하는 화염디스크로부터 화염구멍으로 천이에 대한 실험 연구가 수행되었다. 이러한 연구는 버너직경, 전체신장율 그리고 속도비에 따라 묘사된다. 적절히 작은 버너 직경을 사용한 경우 고신장율 화염임에도 반경방향의 전도 열손실의 효과가 기여하는 것을 실험적으로 입증하였다. 그리고 화염소화 모드는 세 가지로 분류되며 특히, 충분히 큰 고신장율 화염의 표면에서 화염구멍 또는 줄무늬로 나타났다. 그리고 버너직경에 따라 화염소화모드를 구분 짓는 임계화염반경이 존재한다.

  • PDF

Heat Transfer Characteristics of Aluminium and FeCrAlY Foam

  • Jin, Meihua;Kim, Pil-Hwan;Lee, Hae-Jong;Jeong, Hyo-Min;Chung, Han-Shik
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.395-401
    • /
    • 2008
  • Since metallic foam will increase the performance of heat exchanger, it have caused many researcher's attention recently. Our research base on the model that metallic foams applied to heat exchanger. In this case, there is three kind of heat transfer mechanisms, heat conduction in fibers, heat transfer by conduction in fluid phase, and internal heat change between solid and fluid phases. In this paper we study both the hydraulic and thermal aspect performance. Pressure drop along air flow direction will be presented. As thermal aspect, we first discuss the acceptance of applying thermal equilibrium among the two phases. then to calculate the dimensionless temperature profile, the heat transfer coefficient and Nu number in 14 metallic foams(7 Aluminium foams, 7 FeCrAlY foams). All these discussion is based on the same velocity u=2 m/s.

  • PDF

Miller Fisher 증후군1예에서 일련의 신경생리학적 소견 (Serial Electrophysiological Studies in Miller Fisher Syndrome)

  • 전동철;박춘강;이규용;이영주;김주한
    • Annals of Clinical Neurophysiology
    • /
    • 제3권2호
    • /
    • pp.156-159
    • /
    • 2001
  • Miller Fisher syndrome(MFS) has been the focus of conflicting opinions regarding the peripheral versus the central nature of the site of major neural injury. We present our electrophysiological findings in one case of MFS to help clarify the pattern of peripheral nerve injury in this syndrome. A 45-year-old man visited our hospital due to sudden diplopia. Initial examination revealed internuclear opthalmoplegia. The next day, his symptoms rapidly aggravated to complete external ophthalmoplegia, ataxia, and areflexia with hand and foot numbness. Serial electrophysiological studies were performed. The results of brainstem evoked potential(BAEP) and blink reflex were normal in the serial studies. Motor and sensory nerve conduction study(NCS) were normal findings in second hospital day, but ulnar sensory nerve shows no sensory nerve action potential(SNAP) and sural sensory conduction velocity was delayed in 7th hospital day. Our patient's clinical presentation began to improve on 15th hospital day, and his electrophysiologic study showed improvement on 29th hospital day. We believe that all the manifestations of MFS can be explained by the involvement of peripheral nerves without brainstem or cerebellar lesion with the serial electrophysiological studies.

  • PDF

PTC형 집열기의 원관형 흡수기에서의 복합열전달 (Conjugate Heat Transfer for Circular Absorber in Parabolic Trough Concentrator)

  • 정종만;서태범;강용혁
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.81-89
    • /
    • 2000
  • In the present study, the characteristics of conductive and convective heat transfer occurred in a circular absorber of PTC (parabolic trough concentrator) for medium temperature solar energy utility were numerically investigated. A circular tube was considered as an absorber and the shape of PTC modeled in this study was based on the system that was installed in Korea Institute of Energy Research. Not only convection inside the tube but also conduction through the wall of the tube were analyzed, simultaneously. Circumferentially non-uniform heat flux that was simulated from the non-uniform solar disc model proposed by Jose was applied as thermal boundary condition on the tube surface. And, hydrodynamically fully developed laminar velocity profile was used as the inlet boundary condition and it was assumed that the working fluid was water. And, local heat fluxes at the interface of the tube and the working fluid were calculated for different wall thickness and thermal conductivity of the tube at various Reynolds number. Based on the results, the effects of thermal conduction of the tube on the local heat transfer were investigated.

  • PDF

손목터널증후군 환자에서 당뇨병이 수술 후 전기생리학적 결과에 미치는 영향 (The Effect of Diabetes Mellitus on Postoperative Electrodiagnostic Outcomes of Carpal Tunnel Syndrome)

  • 곽중민;정영하;강석;윤준식
    • 대한근전도전기진단의학회지
    • /
    • 제20권2호
    • /
    • pp.91-97
    • /
    • 2018
  • Objective: The aim of this study was to compare the electrodiagnostic outcomes of carpal tunnel release in patients with and without diabetes with carpal tunnel syndrome (CTS), and to evaluate the effect of diabetes mellitus (DM) on electrodiagnostic outcomes. Method: We conducted a retrospective analysis of 67 patients with electro-diagnostic evidence of CTS. Patients were classified into two groups according to the presence of DM. Both groups were evaluated using nerve conduction studies preoperatively and 3 weeks and 3 months postoperatively. Results: There were no statistical differences in any of the electrodiagnostic parameters between groups 3 weeks postoperatively. However, there were statistical differences in the amplitude and the latency of compound muscle action potential, and sensory nerve conduction velocity 3 months postoperatively. Conclusion: Patients with DM did not show a significantly different outcome 3 weeks after surgery but showed a worse electrodiagnostic outcome 3 months after surgery than those without DM.

Axonal Charcot-Marie-Tooth case with a novel heterozygous variant in MFN2 assessed by the MutationDistiller

  • Ryu, Ho-Sung;Lee, Yun-Jeong;Lee, Jong-Mok
    • Journal of Genetic Medicine
    • /
    • 제17권2호
    • /
    • pp.89-91
    • /
    • 2020
  • Charcot-Marie-Tooth (CMT) disease can be divided mainly into demyelination and axonopathy based on the results of the electrophysiological study. Mitofusin 2, encoded by MFN2 gene, has a crucial role in the fusion of mitochondria, which is known to associate with CMT type 2A as one of the axonal forms. We describe a 44-year-old man with progressive weakness on bilateral legs after noticing foot drop in his early teen. When we examined him at 45 years of age, he presented atrophy on entire legs and with distal muscle weakness on limbs. The nerve conduction study revealed severely decreased amplitude on motor nerve ranging from 0.2 to 4.5 mV, while conduction velocity remained more than 30.4 m/s. The whole-exome sequencing revealed a novel variant c.2228G>T in MFN2 by efficient genetic analysis tool, MutationDistiller. This report will not only expand the mutation spectrum of CMT2A but also introduce a time-saving genetic analysis tool.