• 제목/요약/키워드: Conduction Parameter

검색결과 119건 처리시간 0.029초

Oxygen Interstitial Defects and Ion Hopping Conduction of $X ThO_2 + (1-X) Gd_2O_3 $Solid Solutions: $O.O8{\le}X{\le}0.12$

  • Park, Sung-Ho;Kim, Yoo-Young;Kim, Keu-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • 제11권4호
    • /
    • pp.339-342
    • /
    • 1990
  • $Gd_2O_3-ThO_2$ solid solutions containing 8,10 and 12 mol % $ThO_2$ were synthesized with spectroscopically pure $Gd_2O_3,$ and $ThO_2$ polycrystalline powders. X-ray diffraction revealed that all synthesized specimens have the modified fluorite structure, and the lattice parameter of $Gd_2O_3$ is nearly unchanged with increasing $ThO_2$ mol %. Both ac and dc conductivities were measured in the temperature range $500-1100^{\circ}C$ under $Po_2's$ from $10^{-6}$ to $10^{-1}$ atm. The dc conductivities are nearly independent of $Po_2,$ and agree with the ac values. This implies that the solid solutions are ionic conductors. The conductivity increases with increasing $ThO_2$ mol % with an average activation energy of 1.23 eV. An oxygen interstitial defect and ionic hopping conduction are suggested.

Electric Therapy System Based on Discontinuous Conduction Mode Boost Circuit

  • Chen, Wenhui;Lee, Hyesoo;Jung, Heokyung
    • Journal of information and communication convergence engineering
    • /
    • 제18권4호
    • /
    • pp.245-253
    • /
    • 2020
  • The human body and nervous system transmit information through electric charges. After the electric charge transmits information to the brain, we can feel pain, numbness, comfort, and other feelings. Electric therapy is currently used widely in clinical practice because the field of examination is more representative of electrocardiogram, and in the field of treatment is more representative of electrotherapy. In this study, we design a system for neurophysiological therapy and conduct parameter calculation and model selection for the components of the system. The system is based on a discontinuous conduction mode (DCM) boost circuit, and controlled and regulated by a single-chip microcomputer. The system does not only have a low cost but also fully considers the safety of use, convenience of the human-computer interface, adjustment sensitivity, and waveform diversity in the design. In future, it will have strong implications in the field of electrotherapy.

리튬 이온 전지용 리튬 코발트 산화물 양극에서의 삽입 전압과 리튬 이온 전도 (Intercalation Voltage and Lithium Ion Conduction in Lithium Cobalt Oxide Cathode for Lithium Ion Battery)

  • 김대현;김대희;서화일;김영철
    • 전기화학회지
    • /
    • 제13권4호
    • /
    • pp.290-294
    • /
    • 2010
  • 본 연구는 밀도 범함수 이론을 이용하여 Li이온전지에 사용되는 Li코발트 산화물에서의 Li이온 삽입 전압과 전도에 관한 것이다. Li이온은 Li코발트 산화물 원자구조의 각 층을 1개씩 채우거나 한 층을 다 채우고 다음 층을 채울 수 있다. 평균 삽입 전압은 3.48V로 동일하나, 전자가 후자보다 더 유리하였다. 격자상수 c는 Li농도가 0.25보다 작을 때는 증가하였으나, 0.25보다 클 때는 감소하였다. Li농도가 증가하면, Li코발트 산화물에서의 Li이온 전도를 위한 에너지 장벽은 증가하였다. Li이온전지가 방전 중 출력 전압이 낮아지는 현상은 Li농도 증가에 따른 삽입 전압의 감소와 전도 에너지 장벽의 증가로 설명할 수 있었다.

NASICON 고체 전해질의 이온 전도도 계산 (II) Na1-Na2 전도 경로에 미치는 mid-Na의 영향 (Computation of Ionic Conductivity at NASICON Solid Electrolytes (II) Effects of mid-Na Sites on Na1-Na2 Conduction Paths)

  • 최진삼;서양곤;강은태
    • 한국세라믹학회지
    • /
    • 제32권11호
    • /
    • pp.1292-1300
    • /
    • 1995
  • The ionic conductivity of NASICON solid electrolytes was simulated by using Monte Carlo Method (MCM). There were included two conduction paths: (1) Na1-Na2 and (2) Na1-Na2 including Na2-Na2. We assumed that mid-Na ions provde an additional driving force for Na mobile ions due to the interionic repulsion between Na1 and Na2 ions. The inflection point of vacancy availability factor, V has been shown at nearby x=2, the maximum mid-Na ions. The inflection point of vacancy availability factor, V has been shown at nearby x=2, the maximum mid-Na sites are occupied. The effective jump frequency factor, V has been shown at nearby x=2, the maximum mid-Na sites are occupied. The effective jump frequency factor, W increased rapidly with the composition at low temperature, but decreased at high temperature region. On Na1-Na2 conduction path, the minimum of charge correlation factor, fc and the maximum of $\sigma$T were appeared at x=2.0. this indicated that mid-Na ions affect on the high ionic conductivity behavior. At the whole range of NASICON composition, 1n $\sigma$T vs. 1/T* plots have been shown Arrhenius behavior but 1n (VWFc) vs. 1/T* have been shown the Arrhenius type tendency at x=2, which mid-Na is being the maximum. The results of MCM agreed with the experimental one when the chosen saddle point value was 6$\varepsilon$ : 3$\varepsilon$. Here the calculated characteristic parameter of materials, K and the phase transition temperature were -4.001$\times$103 and 178$^{\circ}C$ (1/T*=1.92, 1000/T=2.22), respectively.

  • PDF

Finite Element Analysis of Temperature Distribution and Thermally Caused Deformation in Ventilated Disk Brakes

  • Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • 제11권5호
    • /
    • pp.150-155
    • /
    • 1995
  • In order to analyze the thermal effects of the rotor models, the finite element technique was used in this study. The length of the hat was investigated as a design parameter. At the start of each brake application the disk surface temperature rapidly increases to a maximum value and then decays due to external cooling and thermal conduction to the hat. The calculated results indicate that the long length of the hat shows the minimum deformation in axial direction, which is related to the thermal problems, coned wear, vibration and noise.

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

$Cul-Cu_2S-Cu_2O-MoO_3$계 유리의 전기전도 및 유전환화와의 상관 (Correlation between Electrical Conduction and Dielectric Relaxation in the Glass System $Cul-Cu_2S-Cu_2O-MoO_3$)

  • 이재형;임기조
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1152-1157
    • /
    • 1994
  • The glasses were prpared in the system CuI-CuS12TS-CuS12TO-MoOS13T by rapid quenching technique. These glasses have high ionic conductivities at 2$0^{\circ}C$ in the range of 10S0-1T[S/m], and the conductivities increase with increasing CuI and CuS12TS content. The value of activation energy for dielectric relaxation is nearly identical with that for conductivity. The cole-Cole parameter $\beta$ for representation of the distribution of dielectric relaxation times varies the range from 0.92 to 0.96. This parameter has a weak dependence on the composition of glass, and is independent of temperature. The correlation factors P for the glasses shows from 1.1 to 1.7.

  • PDF

수직 평판휜으로부터의 복합자연대류에 미치는 복사효과 (Effects of Radiation on Conjugate Natural Convection from a Vertical Plate Fin)

  • 김경훈;김세웅
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.382-390
    • /
    • 1992
  • The problem of natural convection from a vertical fin is solved by coupling the thermal diffusion equation in the fin to the constitutive equations of the ambient medium involving the radiation of the medium. The analysis is accomplished by employing an integral method. The governing equations for the problem are solved by shooting method based on the Runge-Kutta Scheme at Pr= 0.7. For the range of values of the fin parameter and the radiation-conduction parameter in the analysis, the numerical results show that the radiation effects play an important role in the heat transfer and enhance the heat transfer.

단상 부스터 콘버터의 입력역률 개선을 위한 가변 밴드폭 제어방식에 관한 연구 (A Study on the Variable Hysteresis Current Mode Control Method for Power Factor Improvement of the Single Phase Boost Converter)

  • 김철우;권순재;유동욱;박성준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권3호
    • /
    • pp.36-43
    • /
    • 1994
  • 본 연구는 교류전원측에서 콘버터에 의해 출력전압조정과 동시에 입력전류가 전압과 동상에 가까운 정현파가 되도록 하기 위해 고주파 스위칭에 의한 단상 부스터 콘버터의 제어방식을 분석하고 가변밴드폭 제어방식에 의해 1[kW]부하에 대하여 각 파라메타를 산정하며 실험장치를 구성하여 주파수 스팩트럼 분석기에 의한 분석을 토대로 고역률 동작을 확인하고자 한다.

  • PDF