• Title/Summary/Keyword: Conduction Parameter

Search Result 119, Processing Time 0.023 seconds

Radiation-Laminar Free Convection in a Square Duct with Specular Reflection by Absorbing-Emitting Medium

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1346-1354
    • /
    • 2002
  • The purpose of this work is to study the effects of specularly reflecting wall under the combined radiative and laminar free convective heat transfer in an infinite square duct. An absorbing and emitting gray medium is enclosed by the opaque and diffusely emitting walls. The walls may reflect diffusely or specularly. Boussinesq approximation is used for the buoyancy term. The radiative heat transfer is evaluated using the direct discrete ordinates method. The parameters under considerations are Rayleigh number, conduction to radiation parameter, optical thickness, wall emissivity and reflection mode. The differences caused by the reflection mode on the stream line, and temperature distribution and wall heat fluxes are studied. Some differences are observed for the categories mentioned above if the order of the conduction to radiation parameter is less than order of 10$\^$-3/ fer the range of Rayleigh number studied. The differences at the side wall heat flux distributions are observed as long as the medium is optically thin. As the top wall emissivity decreases, the differences between these two modes are increased. As the optical thickness decreases at the fixed wall emissivity, the differences also increase. The difference of the streamlines or the temperature contours is not as distinct as the side wall heat flux distributions. The specular reflection may alter the fluid motion.

Conductive-Radiative Heat Transfer in an Infinite Square Duct with Dielectric Directional Property Wall (부도체 방향복사면이 있는 무한 정사각관의 전도-복사열전달)

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.543-552
    • /
    • 2003
  • The effects of a directionally emitting and reflecting dielectric surface on the wall heat flux and medium temperature distribution are studied. The system is an infinite square duct enclosing an absorbing and emitting medium. The emissivity and reflectivity of opaque and gray wall vary with direction. Combined effect of conductive and radiative heat transfer is analyzed using finite difference and the direct discrete-ordinates method. The parameters under study are conduction to radiation parameter, optical depth, refractive index ratio. The results with directional and diffuse properties deviate each other when the conduction to radiation parameter is less than around 0.01. The wall heat flux differs fur optical thickness less than around 0.1. However, the medium temperature profiles differ for optical thickness greater than around 1. Deviations from diffuse property calculations are larger for hot wall with directional property than cold wall with directional property. As n increases from 1.5, the trend changes are observed fur refractive index ratio about n=6.10

Analysis of Subthreshold Swing Mechanism by Device Parameter of Asymmetric Double Gate MOSFET (소자 파라미터에 따른 비대칭 DGMOSFET의 문턱전압이하 스윙 분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.156-162
    • /
    • 2015
  • This paper has analyzed how conduction path and electron concentration for the device parameters such as oxide thickness, channel doping, and top and bottom gate voltage influence on subthreshold swing of asymmetric double gate MOSFET. Compared with symmetric and asymmetric double gate MOSFET, asymmetric double gate MOSFET has the advantage that the factors to be able to control the short channel effects increase since top and bottom gate oxide thickness and voltages can be set differently. Therefore the conduction path and electron concentration for top and bottom gate oxide thickness and voltages are investigated, and it is found the optimum conditions that the degradation of subthreshold swing, severe short channel effects, can reduce. To obtain the analytical subthreshold swing, the analytical potential distribution is derived from Possion's equation. As a result, conduction path and electron concentration are greatly changed for device parameters, and subthreshold swing is influenced by conduction path and electron concentration of top and bottom.

A Parameter Study on the Frequency Characteristics Control of Implantable Bone Conduction Transducer Using FEA (FEA를 이용한 이식형 골전도 진동체의 주파수 특성 제어에 관한 파라미터 연구)

  • Shin, Dong Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.8
    • /
    • pp.1040-1048
    • /
    • 2020
  • In this study, in order to improve the implantable bone conduction transducer of the prototype proposed by Shin et al., the effect of the element parameters of the transducer on the frequency characteristics was analyzed using electromagnetic and mechanical vibration analysis. Electromagnetic analysis was performed on the size of the permanent magnet and the distance between the metal plate and the coil to derive an optimal structure that generates the maximum Lorentz force. In addition, mechanical vibration analysis was performed on the cantilever structure of the vibrational membrane in order to minimize the distortion of the transducer and to have a frequency characteristic suitable for conductive hearing loss compensation. The frequency characteristics of the transducer of the optimal structure derived through finite element method were compared with the simulation results of the previous transducer. As a result, the output magnitude (displacement) of the transducer designed with the optimal structure generated an average 8.8 times higher than the previous transducer, and the resonance frequency was generated at 0.9 kHz.

An Inverse Analysis of Two-Dimensional Heat Conduction Problem Using Regular and Modified Conjugate Gradient Method (표준공액구배법과 수정공액구배법을 이용한 2차원 열전도 문제의 역해석)

  • Choi, Eui-Rak;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1715-1725
    • /
    • 1998
  • A two-dimensional transient inverse heat conduction problem involving the estimation of the unknown location, ($X^*$, $Y^*$), and timewise varying unknown strength, $G({\tau})$, of a line heat source embedded inside a rectangular bar with insulated boundaries has been solved simultaneously. The regular conjugate gradient method, RCGM and the modified conjugate gradient method, MCGM with adjoint equation, are used alternately to estimate the unknown strength $G({\tau})$ of the source term, while the parameter estimation approach is used to estimate the unknown location ($X^*$, $Y^*$) of the line heat source. The alternate use of the regular and the modified conjugate gradient methods alleviates the convergence difficulties encountered at the initial and final times (i.e ${\tau}=0$ and ${\tau}={\tau}_f$), hence stabilizes the computation and fastens the convergence of the solution. In order to examine the effectiveness of this approach under severe test conditions, the unknown strength $G({\tau})$ is chosen in the form of rectangular, triangular and sinusoidal functions.

Improvement of Stimulus Pattern and Design of Discrimination System for Coincident ratio Elevation with Traditional Meridians (고전경락과의 부합율 향상을 위한 경혈자극방식의 개선 및 식별시스템의 설계)

  • Lee, Yong-Heum;Ko, Su-Bok;Jeong, Dong-Myong
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.22-31
    • /
    • 2003
  • Conventional stimulus patterns have used DC for discrimination of acupoint and meridian which is the basic object of diagnosis and medical treatment in oriental medicine. Those discriminate conduction points by stimulation on body skin with DC. But, it is insufficient to reliability in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper has extracted the optimal parameter of frequency and waveform in order to improve conventional pattern, and proposed the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, We proposes algorithm which is able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It can decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. We have compared the performance of system applying the extracted optimal parameter and algorithm. We have compared discrimination, coincident ratio of both conduction point and traditional acupoints by acupoint stimulation pattern. In the results, we confirmed reliability of SPAC stimulus pattern.

  • PDF

Analysis of a new Soft-Switching High-Frequency Inverter for High Current (대전류화를 위한 새로운 소프트 스위칭 고주파 인버터의 회로 해석)

  • Lee, E.Y.;Ra, B.H.;Suh, K.Y.;Kwon, S.K.;Lee, H.W.;Kwak, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1187-1189
    • /
    • 2002
  • In the case of an existing high frequency inverter is became forced extinction by quick load change, due to be connected with series inductor on switch, it is destroyed or is generated conduction loss by resistance component in reactor. And, In the operation of high current with a soft switching, conduction loss can not neglect. In this paper, for the high current power source, we make sure of soft swtching operation and reducing surge when the forced extinction by using a connected switch with series inductor. Also, we poropos a topology of the half bridge type high frequency inverter that can be realized high amplitude operation of the load current. And, analyze the circuit to decide an opmtial circuit parameter.

  • PDF

Conjugate Heat Transfer in a Vertical Channel with Protrunding Heat Source (돌출된 열원이 부착된 수직 채널내 복합열전달)

  • Kim, Ui-Gwang;Baek, Byeong-Jun;Jo, Byeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.741-751
    • /
    • 1996
  • The coupled conduction and convection heat transfer from the protruding heat source in a vertical channel is numerically investigated. Conjugate solution of the two-dimensional energy equation is obtained for the incompressible air flow over the rectangular block with local heat source. It was found that several recirculation zones and separation bubble near the block were related to Re and Gr. And the results show that fractions of the heat transfer through each of the block face, maximum temperature of the block and the relative effect of each parameter on the maximum temperature and heat transfer.

A Study on the Design of Sensory Nerve Conduction Velocity Measurement System (감각신경 전도속도 측정시스템 설계에 관한 연구)

  • Yoo, S.K.;Min, B.G.;Kim, J.W.;Kim, J.W.;Yoon, H.R.;Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.89-92
    • /
    • 1992
  • The sensory nerve study is the important index to diagnosis peripheral neuromyotic disease. This paper discusses about the design of parameter - latency, amplitude, conduction velocity - measurement system in the sensory nerve. This system consists of three parts which are Main Control Unit(MCU), Stimulator, and external output unit. Also new measurement algorithms which is adaptive threshold method is presented in this paper. The designed system is controlled by MCU includes automatic detection algorithms and self-diagnostic functions.

  • PDF

High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching (다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터)

  • Ra, B.H.;Suh, K.Y.;Lee, H.W.;Kim, K.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF