• 제목/요약/키워드: Conduction

검색결과 3,628건 처리시간 0.031초

A Study on the Electric Conduction Mechanism of Polyimide Ultra-Thin Films

  • Jeong, Soon-Wook;Park, Won-Woo;Lee, Sang-Jae
    • 한국응용과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.238-242
    • /
    • 2006
  • Polyimide is a well-known organic dielectric material, which has not only high chemical and thermal stability but also good electrical insulating and mechanical properties. In this research, the electric conduction mechanism of PI Ultra-Thin Films was investigated at room temperature. At low electric field, ohmic conduction $(I{\propto}V)$ was observed and the calculated electrical conductivity was about $4.23{\times}10^{-15}{\sim}9.81{\times}10^{-15}\;S/cm$. At high electric field, nonohmic conduction $(I{\propto}V^2)$ was observed and the conduction mechanism was explained by space charge limited region effect. The dielectric constant of PI Ultra-Thin Films was about 7.0.

고온초전도체 SMES 장치의 전도냉각시스템 연구 (A Study of a Conduction Cooling System of a HTS SMES System)

  • 고득용;이관수
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.328-332
    • /
    • 2007
  • A superconducting magnetic energy storage (SMES) system has shorter response time and longer life time, and is more economical, and environment-friendly than other uninterruptible power supply (UPS). A conduction cooling system is well answer for the high temperature superconductor (HTS) SMES system. Because the conduction cooling system is simple, light and small structure. The purpose of this paper is to design and verify the effective conduction cooling system for the HTS SMES system. The analysis of heat loads in cryostat is performed. Thermal shield heat loads, temperatures of HTS coil surface and conduction Cu plate are estimated and measured.

INVESTIGATIONS OF CONDUCTION MECHANISM OF ORGANIC MOLECULES USED AS BUFFER HOLE INJECTING LAYER IN OLEDS

  • Shekar, B. Chandar;Rhee, Shi-Woo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.966-969
    • /
    • 2003
  • Thin film capacitors with Al-Polymer-Al sandwich structure were fabricated. The bottom and top aluminium (Al) electrodes were deposited by vacuum evaporation and copper phthalocyanine (CuPc), polyaniline-emeraldine base (Pani-EB) and cobalt phthalocyanine/polyaniline - emeraldine base (CoPc /Pani-EB) blend films (which can be used as buffer hole injection layer in OLEDs) were deposited by spin coating technique. X-ray diffractograms indicated amorphous nature of the polymer films whose thicknesses were measured by capacitance and Rutherford Backscattering Spectrometry (RBS) methods. AC conduction studies revealed that the conduction mechanism responsible in these films is variable range hopping of polarons. From D.C conduction studies, it is observed that, the nature of conduction is ohmic in the lower fields and at higher fields the dominating D.C conduction is of Poole-Frenkel type.

  • PDF

NASICON 고체전해질의 이온전도도 계산 (I) Mid-Na의 영향을 고려하지 않은 경우 (Computation of Ionic Conductivity in NASICON Solid Electrolytes (I) Conduction Paths with no Mid-Na Sites)

  • 최진삼;서양곤;강은태
    • 한국세라믹학회지
    • /
    • 제32권8호
    • /
    • pp.957-965
    • /
    • 1995
  • The ionic conductivityof NASICON solid electrolytes was simulated by using Monte Carlo Method (MCM) based on a hopping model as functions of temoperature and composition. Two conduction paths were used : jumping from Na1 to Na2 and jumping from Na1 to Na2 and jumping from Na2 to Na2. Vacancy availability factor, V was affected by composition, temperature and the conduction paths. For β"-Alumina, it was known that the minimum of charge correlation factor, fc appears at the composition, p=0.5, but there was not shown the minimum of fc for NASICON. When the NASICON composition, x, approaches 2.5, the curve of In σT vs. 1/T* was shown Arrhenius behavior and also In (VWfc) was a linear function of 1/T*. The results of simulations on the considered conduction paths didn't agree with the experimental results. Thus it will be necessary to include the another Na sites as mid-Na site on the conduction path to obtain the better results.

  • PDF

원관 주위의 대류 열전달에서 경계조건에 대한 원주방향 열전도의 영향 (Effect of Circumferential Wall Heat Conduction on Boundary Conditions for Convection Heat Transfer from a Circular Tube in Cross Flow)

  • 이상봉;이억수;김시영
    • 한국해양공학회지
    • /
    • 제15권2호
    • /
    • pp.39-45
    • /
    • 2001
  • With uniform heat generation from the inner surface of the cylindrical heater placed in a cross flow boundary condition, heat flow that is conducted along the wall of the heater creates a non-isothermal surface temperature and non-uniform heat flux distribution. In the present investigation, the effects of circumferential wall heat conduction on convection heat transfer is investigated for the case of forced convection around horizontal circular tube in cross flow of air. The wall conduction number which can be deduced from the governing energy equation should be used to express the effect of circumferential wall heat conduction. It is demonstrated that the circumferential wall heat conduction influences local Nusselt numbers of one-dimensional and two-dimensional solutions.

  • PDF

X-선 중심 가광 초신성 잔해 : 성간운 증발과 열전도 모델 (CENTRALLY PEAKED X-RAY SNRS : CLOUD EVAPORATION AND THERMAL CONDUCTION)

  • 최승언;정현철;박병건
    • 천문학논총
    • /
    • 제14권2호
    • /
    • pp.69-78
    • /
    • 1999
  • We present the results of one-dimensional numerical simulations of SNR evolution in the in­homogeneous medium considering the effects of the evaporation of the cloud and the thermal conduction. We have included the effects of changing evaporation rate as a function of cloud size and the ambient temperature so that the clouds could be evaporated completely before they reach the center of the SNR. The heat conduction markedly changes the density distribution in the remnant interior. To explain the observed morphologies of the centrally peaked X-ray SNRs(for example W44), the maximal thermal conduction is required. However, this is unlikely due to the magnetic field and the turbulent motion. The effects of the evaporation of the cloud and the thermal conduction described here may explain the class of remnants observed to have centrally peaked X-ray emmision.

  • PDF

반도전 전극에 들어 있는 계면활성제가 XLPE의 전기전도 특성에 미치는 영향 (Effects of Surfactant in Semicon Electrode on Electrical Conduction of XLPE)

  • 조준상;서광석;이건주
    • 한국전기전자재료학회논문지
    • /
    • 제13권3호
    • /
    • pp.227-234
    • /
    • 2000
  • Electrical conduction characteristics of crosslinked polyethylene(XLPE) were investigated using an electrode made of semicon material containing a surfactant. When the semicon material is used as an electrode the conduction of XLPE obeys a space charge limited conduction(SCLC) mechanism which holds true for both control and surfactant-containing semicon electrodes. Conduction currents get higher with the addition of surfactant in the semicon electrodes while the charge mobility increases with the increase of surfactant content in the semicon electrode. The diffusion of surfactant molecules into the XLPE was confirmed via a $\mu$-FTIR analysis. It was found through a measurement of spatial charge distributions that the surfactant in the semicon electrodes enhances the injection of negative charge into the XLPE from the electrode. Experimental results and their origins are discussed in detail.

  • PDF

수근관 증후군 치료결정의 한 요인으로 연령의 중요성 (The Importance of Age as a Factor of Carpal Tunnel Syndrome management)

  • 김자영;박혜윤;강성수
    • Annals of Clinical Neurophysiology
    • /
    • 제3권1호
    • /
    • pp.15-20
    • /
    • 2001
  • Background : Carpal tunnel syndrome(CTS) is the most common entrapment neuropathy that refers to a group of signs and symptoms resulting from compression of the median nerve at the wrist. The course of CTS in older patients is different from the younger patients. This difference may be the result of different underlying mechanisms. The different nerve conduction studies of CTS may signify different approaches in management. This study was done to assess the differences in nerve conduction study of CTS in younger and older patients. Methods : This study involved 224 patients who visited Gachon Medical School, Gil Medical Center and was diagnosed by nerve conduction study from October 1997 to October 1999. We compared the results of nerve conduction study to age, especially in between those under 60 years and those 60 years or over CTS patients. Nerve conduction study consists of motor studies of both median nerves(terminal latency, compound action potential) and sensory studies(nerve conduction velocity, nerve action potential). And we also evaluated the variables between younger and older patients group. Those variables include sex, symptom period, laterality, abnormal physical findings and radiculopathy. Results : We found that a significant increase of terminal latency(p<0.1), but a decrease in compound motor action potential(p<0.05) in older patient's group. There was no significant differences in sensory nerve conduction velocity and action potential between those under 60 years and those 60 years or even patients. And also there was no significant difference in sex, symptom period, laterality, abnormal physical findings, radiculopathy between older and younger patients. Conclusions : This study showed a significant increase in the terminal latency and a decrease in compound action potential in older patients. The different nerve conduction studies of CTS by age effect may need different approaches in management.

  • PDF

신경전도검사의 정상치에 관한 연구 (Study on Normal Nerve Conduction Parameters)

  • 한송이;김대성;박규현
    • Annals of Clinical Neurophysiology
    • /
    • 제1권2호
    • /
    • pp.118-125
    • /
    • 1999
  • Background and Aims : Nerve conduction study is invaluable in clinical neurology, especially for assessing peripheral neuropathies. Abnormal nerve conduction studies may result not only from peripheral nerve dysfunction itself, but also from other various mechanical, technical, and physiological factors such as age, sex, height and temperature. So we conducted this study to establish the our own normal values. Methods : In this study, from March. 1997 to July. 1998, 40 Korean adults among person came to Health Promotion Center over the age of 20 without any suspicion of neurological deficits were analysed to determine the effect of compound effects of several physiological factors. Results : The nerve conduction velocities of the upper extremity and proximal segments were faster than those of the lower extremity and distal segments. Physiological factors such as age, height and temperature affect the results of nerve conduction studies in multiple regression analysis. The sex difference is recognized over peroneal motor nerve. There are no sex differences in amplitude transformed into normal distribution. The significant physiological factor affecting the amplitude of nerve conduction is age, whereas height and temperature play no role. Conclusions : In multiple regression analysis, height is widespread variable for the nerve conduction velocities and temperature is important variable for lower extremities. The parametric statistical analysis cannot be applied to the amplitude of the compound muscle or nerve action potentials because of marked left shift in distribution. Sqareroot transformation of the CMAP and CNAP may be useful in normalizing the distribution. The most significant physiological factor affection the amplitude is age. Sex differences are not seen in nerve conduction study.

  • PDF

가쪽넙다리피부신경전도검사의 체질량지수와 나이에 따른 다양성 (Lateral Femoral Cutaneous Nerve: Variety in Conduction (Seror's Method) According to Body Mass Index and Age)

  • 김현영;한양숙;고성호;김주한;김승현
    • Annals of Clinical Neurophysiology
    • /
    • 제8권2호
    • /
    • pp.152-157
    • /
    • 2006
  • Background: Meralgia paresthesia (MP) is characterized by sensory impairment in the anterolateral aspect of the thigh and usually caused by a lateral femoral cutaneous nerve (LFCN) lesion. It is well known that several physiologic factors including age, obesity, and sex can affect nerve conduction. This study aimed to determine whether body mass index (BMI) and age can influence on the conduction velocity and action potential amplitude of the LFCN. Methods: Fifty six individuals without any previous neuromuscular disease participated in this study. LFCN was studied orthodromically, distally from the anterior superior iliac spine. The values, such as sensory nerve action potential (SNAP) amplitude and sensory nerve conduction velocity (NCV) were obtained. SNAP of the LFCN were formed on both sides in forty three individuals. Results: No difference of demographic factors was observed between two groups divided according to the presence of SNAP formation. BMI had a significant relationship with SNAP amplitude and NCV of the LFCN. Moreover, Multiple regression analyses of nerve conduction values showed the significant correlation of body mass index and age with nerve conduction velocity. Conclusions: We may suggest that nerve conduction of the LFCN can be affected by age and BMI. Further study to obtain normal nerve conduction data and compare these data with those of meralgia paresthetica patients should be continued.

  • PDF