• Title/Summary/Keyword: Condensing

Search Result 407, Processing Time 0.025 seconds

Experimental Study on R-l34a Condensation Beat Transfer Characteristics in Plate and Shell Heat Exchanger (판각형 열교환기내의 R-134a 응축열전달 특성에 관한 실험적 연구)

  • 이기백;박재홍;서무교;이희웅;김영수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.108-116
    • /
    • 2003
  • In this paper, the experimental results of condensation heat transfer were reported for the plate and shell heat exchangers(P&SHE) using R-l34a. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-l34a in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by three plates of geometry with a corrugated trapezoid shape of a chevron angle of 45$^{\circ}$. Downflow of the condensing R-l34a in one channel releases heat to the cold up flow of water in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality of R-l34a on the measured data were explored in detail. The results indicate that at a higher vapor quality the condensation heat transfer coefficients are significantly higher. Condensation heat transfer coefficients were increased when the refrigerant mass flux was increased. A rise in the average heat flux causes an slight increase in the hr. Finally, at a higher system pressure the hr is found to be lower. Correlation is also provided for the measured heat transfer coefficients in terms of the Nusselt number.

Studies on the Synthesis and Antibacterial Activity of 2-Ethoxymethyl-3-(5-nitro-2-furyl)acrylamide Derivatives (2-Ethoxymethyl-3-(5-nitro-2-furyl)acrylamide 유도체(誘導體)의 합성(合成) 및 항균작용(抗菌作用)에 관(關)한 연구(硏究))

  • Ko, Ok-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.10 no.4
    • /
    • pp.8-22
    • /
    • 1980
  • In order obtain some new antibacterial agents, seven new 2-ethoxymethyl-3-(5-nitro-2-furyl) acrylamide derivatives were synthesized by condensing 2-ethoxymethyl-3-(5-nitro-2-furyl) acyloyl chloride with amino compounds namely 5-amino-3, 4-dimethyl isoxazole, sulfamonomethoxazole, d-2-amino-1-butanol, hydroxylamine hydrochloride, semicarbazide hydrochloride, thiosemicarbazide, and p, p'-diaminodiphenylsulfone, respectively. The seven synthesized compounds were 2-ethoxymethyl-3-(5-nitro-2-furyl) acryl-5-amino-3, 4-dimethylisoxazoleamide [VII], $N^4-[2-ethoxymethyl\;3-methyl\;(5-nitro-2-furyl)\;acryl]-N^1-(5-methyl-3-isoxazolyl)$ sulfanilamide [VIII], 2-ethoxyl-3-(5-nitro-2-furyl) acrylsemicarbazide [X], 2-ethoxymethyl-3-(5-nitro-2-furyl) acrylthiosemicarbazide [XI], 2-ethoxymethyl-3-(5-nitro-2-furyl) acryl-d-2-amino-1-butanolamide [XII], and 4, 4'-di[2-ethoxymethyl-3-(5-nitro-2-furyl) acryl-amido] diphenylsulfone [XIII]. These compounds, with exception of the compound XIII, showed generally effective antibacterial activity, especially in the following instances. Compound VII was shown to be effective against Bacillus subtilis ATCC 6633 compound VIII, against Bacillus cereus var. Mycoides ATCC 1778, and compound XII, against both Proteus vuglaris and Saccharomyces cerevisiae ATCC 9763.

  • PDF

A Study on the Condensation Heat Transfer of Low Integral Fin Tubes (낮은 핀 관의 응축 열전달 성능에 관한 연구)

  • Han, Gyu-Il;Park, Seong-Guk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.1
    • /
    • pp.67-77
    • /
    • 1996
  • The heat transfer performance of R - 11 vapor condensing on integral fin tubes has been studied using fin tubes having the fin density from 748 to 1654 fins per meter. Electric heater supplied heat energy to the boiler to generate R - 11 vapor over the range of 25-60W. Condensation rates of each tubes were tested under the condition of cooling water flow rate from 400l/h to 2500l/h. For the seven fin tubes tested, the best performance has been obtained with a tube having a fin density of 1417fpm and a fin height of 1.3mm. This tube has yielded a maximum value of the heat transfer coefficient of 16500W/$m_2$K, at a vapor to wall temperature difference of 3K. Experimental results of integral fin tubes have been compared with available predictive models such as Beatty - Katz's analysis, Webb's analysis, Sukhatme's analysis and Rudy's empirical relation. The experimental results were shown to be in good agreement with that of the Sukhatme's analysis.

  • PDF

Prediction of condensation heat transfer coefficients inside horizontal tube in annular flow regime (환상유동 영역에서의 수평관내 응축 열전달계수 예측)

  • Kwak, Kyung-Min;Bae, Chul-Ho;Jung, Mo;Lee, Sang-Chun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.732-742
    • /
    • 1998
  • Prediction method for heat transfer coefficients in a horizontal smooth tube with forced convection condensation is proposed. In this paper, the analogy between momentum and heat transfer was applied to an annular flow regime and the logarithmic velocity distribution is applied to describe the velocity profile within the liquid film. Prediction results are compared with those of experimental ones. The test refrigerants are R113, R22, R134a, R407C(R33/R125/R134a, 23/25/52 wt%), R410A(R32/R125, 50/50 wt%) and R134a+R123(R134a/R123, 85.5/14.5 wt%) which are used under operating conditions in a condenser of air-conditioner. The proposed prediction method shows good agreement with experimental data within$\pm 30%$ for pure refrigerants. For the mixture refrigerants including the ternary mixture refrigerant R407C, condensation heat transfer from this study are higher than those from experiments. By correcting the constant in two-phase frictional multiplier, the predicated heat transfer coefficients become similar to the experimental results.

  • PDF

Automatic translation system for hangul's romanization Based on the World Wide Web (웹 기반하의 국어의 로마자 전사 표기 자동 변환 시스템)

  • 김홍섭
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.4
    • /
    • pp.108-114
    • /
    • 2002
  • After automatic translation system for hangul's romanization based on the World Wide Web converting korean-word, sentence, document to Transliteration letters by applying algorithm based phonological principles. even though a user do not know the basic principles of the usage of Korean-to-Romanization notations, It refers to corresponding character table that has been currently adopted the authority's standard proposition for Korean-to-Romanization notation rule concurrently, add to make possible to convert a machinized code as well. It provides font for toggling Korean-English mode, insert-edit mode by assigning ASCII codes and Unicode are hardly used to them. This program could be made in C++ progamming language and Unified Modeling Language to implement various font. font-expanding and condensing. alternative printing.

  • PDF

A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside (보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구)

  • Lee, Young-Lim;Park, Sang-Jun;Hwang, Il-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.10
    • /
    • pp.711-717
    • /
    • 2012
  • A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

Syntheses of 5-Fluorouracil-Fat Conjugates and Evaluation of Their in vitro Cytotoxic Activity (5-Fluorouracil-지질 결합체 합성 및 in vitro 항암효과 평가)

  • Lee, Hee-Joo;Chang, Pan-Sup;Kim, Jae-Wan;Jung, Ki-Hwa;Shin, Soon-Hee;Shin, Hae-Soon;Jung, Soon-Bog
    • YAKHAK HOEJI
    • /
    • v.34 no.6
    • /
    • pp.395-400
    • /
    • 1990
  • The FU-fat conjugates(4a-e) as a prodrug have been synthesized by condensing various fatty acids(1a-e) via isocyanates(2a-e) as carbamoyl group at $N^1-position$ of 5-fluorouracil and their structures characterized. Preliminary testing for their antitumor effect was carried out on leukemia L1210 cells in culture. Most of them(4a-d) like the parent FU exhibited less than 50% inhibition on grouth of the cultrued cells at the concentration of $1\;{\times\;10^{-7}M$. Only a dicarboxylic acid derivative, 4e, showed over 50% inhibition at the same level.

  • PDF

Experimental Study on R-22 Condensation Heat Transfer Characteristic in Plate and Shell Heat Exchanger (Plate and Shell 열교환기 내의 R-22 응축열전달 특성에 관한 실험적 연구)

  • Seo, Mu-Gyo;Park, Jae-Hong;Kim, Yeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.860-867
    • /
    • 2001
  • In this study, condensation heat transfer experiments were conducted with plate and shell heat exchangers(P&SHE) using R-22. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-22 in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by three plates of geometry with a corrugated trapezoid shape of a chevron angle of 45°. Downflow of the condensing R-22 in one channel releases heat to the cold upflow of water in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality of R-22 on the measured data were explored in detail. The results indicate that at a higher vapor quality the condensation heat transfer coefficients are significantly higher. A rise in the refrigerant mass flux causes an increase in the h(sub)r. Also, a rise in the average heat flux causes an increase in the h(sub)r. Finally, at a higher system pressure the h(sub)r is found to be slightly lower. Correlation is also provided for the measured heat transfer coefficients in terms of the Nusselt number.

A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat (증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구)

  • 김재돌;오후규;윤정인
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.

An Empirical Correlation of Refrigerant Flow Rate Through Coiled Capillary Tubes (코일 형상을 고려한 모세관 냉매유량 예측 상관식)

  • Park, Cha-Sik;Jang, Yong-Hee;Lee, Young-Soo;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.91-98
    • /
    • 2007
  • Air-conditioners use a spirally coiled capillary tube as an expansion device to enhance compactness of the unit. However, most empirical correlations in open literature were developed for straight capillary tubes without considering coiled effects on the mass flow rate. The objectives of this study are to investigate the flow characteristics of coiled capillary tubes and to develop a generalized correlation for mass flow rate through coiled capillary tubes. The mass flow rates through the coiled capillary tubes and straight capillary tubes were measured by varying operating conditions and tube geometry. The condensing temperatures varied at 40.5, 47.5 and $54.5^{\circ}C$, and subcoolings altered at 3.5, 6.5 and $11.5^{\circ}C$. The mass flow rates of the coiled capillary tubes decreased by 5 to 16% compared with those of the straight capillary tubes at the same operating conditions. An empirical correlation was developed by introducing equivalent length of capillary tube with non-dimensional parameters for coiled shape. The present correlation predicts the data with average and standard deviations of 0.33% and 3.24%, respectively.