• 제목/요약/키워드: Condenser fouling

검색결과 16건 처리시간 0.026초

엇갈림 관군에서 원관 주위의 열전달에 미치는 파울링 영향에 관한 실험적 연구 (An Experimental Study of Fouling Effect on the Heat Transfer Around a Tube in Staggered Tube Banks)

  • 김민수;백병준;박복춘
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1478-1485
    • /
    • 2000
  • An experimental study has been performed to investigated the forced convection heat transfer characteristics of 6 circular cylinders in staggered arrangement in a cross flow of air. The water scale deposited on condenser wall of power plant was used to investigate the effect of roughness of scaled surfaces. The relative roughness*average diameter of scale/cylinder diameter) was in a range of k/d=0.0066, 0.0111, 0.0167, 0.0222 and 0.0278. The cylinder spacings(L/d) varies from 1.5 to 4.0 where L denote the cylinder spacings along and normal to the upstream uniform flow direction. The Reynolds number was varied in a range of 10, 000$\leq$ Re $\leq$ 50,000. The local and mean Nusselt numbers were investigated as a function of scale roughness, the cylinder spacing and Reynolds number. The results are compared with those of clean cylinder and inline tube bank, subsequently the mean fouling resistance over the entire circumference was estimated from those results as a function of scale roughness, the cylinder spacing and Reynolds number.

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.

전류정보를 이용한 가변속냉동시스템의 열교환기 실시간 고장 진단 (On-line Fault Detection and Diagnosis for Heat Exchanger of Variable Speed Refrigeration System Based on Current Information)

  • 이동규;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.88-94
    • /
    • 2007
  • This study deals with on-line fault detection and diagnosis for heat exchanger of variable speed refrigeration system. Conventional studies about fault of heat exchanger in refrigeration system have used temperature and pressure information. The temperature and pressure are able to be used valuably for faults detection of constant speed refrigeration system. However in case of variable speed refrigeration system, the temperature and pressure are no longer useful information for fault detection due to compensation effect of feedback controller. While current information is possible to detect faults of variable speed refrigeration system. The current information was detected in an inverter, it was used after transforming rms value. The faults of variable speed refrigeration system are divided into electrical faults and mechanical faults. We performed fault detection and diagnosis about heat exchanger among mechanical faults such as condenser fouling and evaporator fan fouling through some experiments.

  • PDF

R-134a 터보냉동기 응축기의 무세정 수처리 약품 효과 연구 (A Study on the Effect of Non-Clean Water Treatment Chemicals for R-134a Turbo-Chiller Condensers)

  • 정다운;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.437-445
    • /
    • 2022
  • This paper presents an experimental study on the main management factors of the condenser contamination such as fouling and corrosion for the R-134a turbo-chiller to save energy, reduce corrosion rates, and reduce maintenance costs through the application of condenser non-cleaning water treatment chemical. The series of experiment is conducted using combining oxidative microbial sterilizers, non-oxidizing microbial sterilizers, and anti-corrosion agents. The leaving temperature difference and corrosion rates for three different combination of chemicals are collected and analyzed. The experimental results show that the cost reduction (4,066,000 Won/year) of the disinfectant (FT-830) can be achieved by adding the oxidative disinfectant (NaOCl) and the non-oxidizing disinfectant (NX-1116). The LTD value is maintained at 1.9℃, and the corrosion rates of copper and carbon steel specimens are 0.07 mpy and 1.61 mpy, respectively.

발전소 수증기 응축기용 전열 촉진관에 대한 연구 (A Study on Enhanced Tubes for Electric Utility Steam Condensers)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.31-41
    • /
    • 2016
  • 본 연구에서는 발전소 응축기를 모사할 수 있는 프로그램을 개발하고 발전소 응축기에 전열 촉진관 적용시 얻을 수 있는 여러 효과에 대하여 검토하였다. 평활관을 촉진관으로 교체한다면, 전열량의 증가에 따른 수증기 응축 온도가 내려가게 되므로 발전소의 효율이 증가하게 된다. 따라서 촉진관을 사용하면 기존 설비를 그대로 두고서도 상당량의 전력 여유도를 확보할 수 있다. 고려된 전열 촉진관은 외경 22.2 mm 티타늄 재질의 코류게이트 관, 리브 조도 낮은 핀관, 삼차원 조도 낮은 핀관이다. 내측 조도의 경우 최적 조도 높이가 존재하였다. 또한 삼차원 조도 낮은 핀관이 다른 두 형상보다 우수하게 나타났다. 삼차원 조도의 경우 원주 방향으로 인접한 딤플 사이에서 흐름 방향으로 선회류가 유발되고 이 선회류에 의하여 열전달이 촉진되기 때문이다. 600 MW 발전소 응축기에 전열 촉진관을 적용하면 0.5 MW~1.3 MW 가량의 추가 전력을 생산할 수 있다. 또한 냉각수 온도가 올라가면 추가 전력도 증가한다. 실제로 발전소 응축기에 적용하기 위해서는 열 성능 외에도 화울링, 부식, 기계적 특성 등이 고려되어야 한다.

기포 유동층 반응기를 이용한 하수슬러지 및 우드펠렛 혼소에 관한 연소 특성 분석 및 비교 (Experimental Study of Co-firing and Emission Characteristics Fueled by Sewage Sludge and Wood Pellet in Bubbling Fluidized Bed)

  • 이영재;김종민;김동희;이용운
    • 청정기술
    • /
    • 제23권1호
    • /
    • pp.80-89
    • /
    • 2017
  • 하수슬러지 고형연료 및 우드펠렛의 전소 및 혼소 실험을 위해 내경 0.1 m, 높이가 1.2 m인 기포 유동층 반응기를 적용하였으며, 장치는 유동층 반응기, 연료 공급장치, 사이클론, 냉각기, 그리고 가스분석기로 구성되었다. 층 물질의 평균입자크기는 $460{\mu}m$이며, 최소 유동화 속도는 $0.21ms^{-1}$이다. 실험에 사용된 연료는 국내산 하수슬러지 고형연료 및 캐나다산 우드펠렛을 적용하였으며, 우드펠렛 기준 혼합율 20, 50, 80%로 고위발열량을 기준으로 산정하였다. 실험 고정변수는 당량비 1.65, 산화제 $100Lmin^{-1}$, 반응기 온도 $800^{\circ}C$, 유동화수 4로 설정하였다. TGA 분석 결과, 하수슬러지의 고형 연료의 연소성이 우드펠렛이 비해 상대적으로 좋지 않았다. 연소시 반응기 온도는 $800{\sim}900^{\circ}C$ 사이로 유지되었으며, 유동층 반응기에서 하수 슬러지 고형연료의 낮은 연소성으로 인해 CO가 상대적으로 높게 측정되었다. 뿐만 아니라 $NO_X$$SO_X$는 하수슬러지 고형연료 내의 질소함량으로 인해 우드펠렛에 비해 높게 측정되었으며, 혼소율이 증가될수록 CO, $NO_X$, 그리고 $SO_X$의 배출이 감소하였다. 혼소에 따른 회분의 거동 및 퇴적 경향에서 모든 조건에 대해 슬래깅/파일링의 가능성이 높은 것으로 분석되었다.