• Title/Summary/Keyword: Concrete temperature

Search Result 2,483, Processing Time 0.033 seconds

Heating and Cooling Performance Characteristics of Ground Source Heat Pump System Utilizing Building Structures as Heat Source and Sink (빌딩 구조체 활용 지열원 열펌프 시스템의 냉난방성능 특성)

  • Kim, Namtae;Choi, Jong Min;Sohn, Byonghu;Baek, Sung-Kwon;Lee, Dong-Chul;Yang, Hee-Jung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.143.2-143.2
    • /
    • 2011
  • Energy foundations and other thermo-active ground structure, energy wells, energy slab, and pavement heating and cooling represent an innovative technology that contributes to environmental protection and provides substantial long-term cost savings and minimized maintenance. This paper focuses on earth-contact concrete elements that are already required for structural reasons, but which simultaneously work as heat exchangers. Pipes, energy slabs, filled with a heat carrier fluid are installed under conventional structural elements, forming the primary circuit of a geothermal energy system. The natural ground temperature is used as a heat source in winter and heat sink in summer season. The system represented very high heating and cooling performance due to the stability of EWT from energy slab. Maximum heat pump unit COP and system COP were 4.9 and 4.3.

  • PDF

Experiment on the Vitrification of Nonflammable Wastes Using AP-200L Plasma Torch (AP-200L 토치를 이용한 비가연성 방사성폐기물 고온용융처리)

  • 최종락;유병수;김천우;박종길;하종현
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.48-53
    • /
    • 2003
  • The high temperature melting test for nonflammable wastes using a plasma torch was conducted. The AP-200L hollow cathode type plasma torch was installed at the pilot plasma melting furnace in NETEC. The surrogates were prepared to simulate concrete, soil and their mixture with steel. The experimental conditions such as feeding rate, the distance between melts surface and torch nozzle, torch rotation speed, gas flow rate and pressure in the furnace were decided. Basic parameters such as temperatures of cooling waters, off-gas and torch power were measured. The vitrified samples were analyzed by SEM/EDS.

  • PDF

The Properties of Fluidity and Compressive Strength of Unsaturated Polyester Polymer Concrete According to Replacement Ratio of Rapidly-Chilled Steel Slag Fine aggregate (급냉 제강 슬래그 잔골재 대체율에 따른 불포화 폴리에스테르 폴리머 콘크리트의 유동성 및 압축강도 특성)

  • Kim, Jae-Won;Seo, Jung-Pil;Sun, Joung-Soo;Chi, Duck-Jin;Hwang, Eui-Hwan;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.43-46
    • /
    • 2007
  • This study dealt with the influence of the replacement ratio of rapidly-chilled steel slag on fluidity and compressive strength of unsaturated polyester polymer concretes. The rapidly-chilled steel slag used in this study, a by-product which is produced by refining pig iron during the manufacture of steel, was controled by a air-jet method which rapidly cools substance melted at a high temperature. Experimental results show that fluidity and compressive strength of unsaturated polyester polymer concretes increase with increasing replacement ratio of rapidly-chilled steel slag. Use of rapidly-chilled steel slag was found to be effective for improving fluidity and compressive strength of rapidly-chilled steel slag.

  • PDF

Investigation of acrylic/boric acid composite gel for neutron attenuation

  • Ramadan, Wageeh;Sakr, Khaled;Sayed, Magda;Maziad, Nabila;El-Faramawy, Nabil
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2607-2612
    • /
    • 2020
  • The present work was aimed to show the possibility of using hydrogel (acrylic/boric acid) for evaluation of the neutron radiation shielding. The influence of acrylic acid concentration, different gamma doses and relative contents of boric acid were studied. The physical properties and the thermomechanical stability of the studied samples were investigated. The shielding property of the composite for neutron was tested by Pu-Be neutron source (5 Ci) under room temperature. The neutron fluence rates and gamma fluxes were measured using a stilbene organic scintillator. The macroscopic effective removal cross-section ΣR (cm-1) of fast neutrons and total attenuation coefficient μ (cm-1) of gamma rays has been studied experimentally. The transmission parameters, the relaxation length (??) and the half-value layer (HVL) were obtained. The obtained results indicated that the addition of boric acid to acrylic acid tends to increase the macroscopic effective removal cross-section ΣR (cm-1) to 0.141 compared to 0.094 of ordinary concrete.

Design of Soft X-ray Tube and Simulation of Electron Beam by Using an Electromagnetic Finite Element Method for Elimination of Static Electric Field (전자기 유한요소법 전자빔 시뮬레이션을 이용한 정전기장 제거용 연한 X-선관 설계 특성 연구)

  • Park, Tae-Young;Lee, Sang-Suk;Park, Rae-Jun
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.66-69
    • /
    • 2014
  • The spreading tube of X-ray cathode tube displayed with an electromagnetic finite element method was designed. To analyze a feature design and the concrete coordinate performance of soft X-ray tube modeling, the orbit of electron beam was simulated by OPERA-3D SW program. The fixed conditions were the applied voltage, the temperature, the work function of thermal electron between cathode and anode of tungsten. Through the analysis of distribution of electron beam and the variation of dividing region, the design of soft X-ray spreading tube equipped with two cross filaments was optimized.

Overview of the Benefits of Structural Fire Engineering

  • Jowsey, Allan;Scott, Peter;Torero, Jose
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The field of structural fire engineering has evolved within the construction industry, driven largely by the acceptance of performance-based or goal-based design. This evolution has brought two disciplines very close together - that of structural engineering and fire engineering. This paper presents an overview of structural systems that are frequently adopted in tall building design; typical beams and columns, concrete filled steel tube columns and long span beams with web openings. It is shown that these structural members require a structural analysis in relation to their temperature evolution and failure modes to determine adequate thermal protection for a given fire resistance period. When this is accounted for, a more explicit understanding of the behaviour of the structure and significant cost savings can be achieved. This paper demonstrates the importance of structural fire assessments in the context of tall building design. It is shown that structural engineers are more than capable of assessing structural capacity in the event of fire using published methodologies. Rather than assumed performance, this approach can result in a safe and quantified design in the event of a fire.

Time-dependent analysis of cable trusses -Part I. Closed-form computational model

  • Kmet, S.;Tomko, M.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.2
    • /
    • pp.157-169
    • /
    • 2011
  • In this paper the time-dependent closed-form static solution of the suspended pre-stressed biconcave and biconvex cable trusses with unmovable, movable and elastic or viscoelastic yielding supports subjected to various types of vertical load is presented. Irvine's forms of the deflections and the cable equations are modified because the effects of the rheological behaviour needed to be incorporated in them. The concrete cable equations in the form of the explicit relations are derived and presented. From a solution of a vertical equilibrium equation for a loaded cable truss with rheological properties, the additional vertical deflection as a time-function is determined. The time-dependent closed-form model serves to determine the time-dependent response, i.e., horizontal components of cable forces and deflection of the cable truss due to applied loading at the investigated time considering effects of elastic deformations, creep strains, temperature changes and elastic supports. Results obtained by the present closed-form solution are compared with those obtained by FEM. The derived time-dependent closed-form computational model is used for a time-dependent simulation-based reliability assessment of cable trusses as is described in the second part of this paper.

A Study on the Field Application Analysis for High Adhesive Spray Type of Degenerated and Rubberized Asphalt Membrane Material (스프레이식 고점착 변성 고무 아스팔트 도막 방수재의 현장 적용성 평가에 관한 실험적 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Choi, Sung-Min;Song, Je-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.4 s.22
    • /
    • pp.85-92
    • /
    • 2006
  • Urethane, epoxy, acrylic have common property to adhere on the concrete dried surface in the waterproofing materials at present. In the wet condition, however, the materials such as urethane, epoxy, acrylic need a long hardening time and it become a reason of water leakage as the materials breaking down. it is one of the problem to adhere to the substrate. Therefore, in this thesis, I focused to assure the structural safety and durability and quality for waterproofing and safe of construction cost by cut down the cost of labor and reduce the term of works as searching the application of field condition for high adhesive spray type of degenerated and rubberized asphalt membrane material.

A Study on the Workability Estimation of Water-Soluble Rubberized Asphalt Waterproofing of Spray Type - Focus on the Material Condition - (수용성 뿜칠형 고무 아스팔트 방수재의 시공성 평가에 관한 연구 - 재료 조건을 중심으로 -)

  • Oh, Sang-Keun;Bae, Kee-Sun;Lee, Won-Hun;Kwak, Kyu-Sung;Choi, Eun-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • This study deals with the estimation of material properties according to the construction condition for water-soluble rubberized asphalt waterproofing material of spray type. In this study, the waterproofing material property by the spray construction method is suggested by means of estimation its tensile performance and temperature dependency according to mix proportion ratio(4:1, 8:1), referenced viscosity and solid content (A:360cps, 76%, B:580cps, 79%, C:490cps, 70%), spray angle($30^{\circ}$, $45^{\circ}$, $60^{\circ}$), and spray distance(30cm, 50cm, 70cm). The result of testing are as follows. (1) The mix proportion ratio of principal agent and hardener is 4:1. (2) The viscosity referenced and solid content are 490cps and 70%. (3) The spray angle referenced is $45.^{\circ}$ (4) The distance referenced from concrete surface to spray gun is 40~50cm.

Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation (동계 아파트 외표면 온도에 의한 단열성능 비교평가)

  • Park, Jung-Hun;Kim, Bong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.91-100
    • /
    • 2013
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. Furthermore, it is to predict the part of occurrence of the thermal bridge and condensation at the apartment building structure. On the other one hand, it is also to analyze the degree of thermal insulation performance according to the standards of thermal insulation and elapsed time, through the analysis by the workability of concrete.